House estimator
Every material for a new house
- 30Rows for this house
- Openings deductedWall by wall
- Planning hoursHours, not money

Everything to buy
Quantities to order, with each calculator’s own waste. Your own rates go on the lines in My Project.
| Material, and where | Quantity |
|---|---|
Continuous Footing / Grade Beam VolumeFT-1, Ground floorHow
| 10.4 yd³ |
Trench Excavation & Backfill VolumeFT-1, Ground floorHow
| 19.69 yd³ |
RebarFT-1, Ground floorHow
| 27 x 20 ft sticks |
ConcreteSL-1, Ground floorHow
| 15.95 yd³ |
RebarSL-1, Ground floorHow
| 92 x 20 ft sticks |
Concrete FormworkSL-1, Ground floorHow
| 19 x 8 ft boards |
| Material, and where | Quantity |
|---|---|
Studs, 2×4 (38 × 89 mm) at 16 in (400 mm) centresEW-1, Ground floor, 4 wallsHowEach corner is counted on one of its two walls, each partition on the wall it meets; each opening's width is its rough opening, the drawn unit plus 25 mm (1 in) as the window takeoff frames it, each kind's mean on the wall.
| 150 studs |
Plates, headers, sills, cripples, corner and junction studsEW-1, Ground floor, 4 wallsHowEach corner is counted on one of its two walls, each partition on the wall it meets; each opening's width is its rough opening, the drawn unit plus 25 mm (1 in) as the window takeoff frames it, each kind's mean on the wall.
| 604.24 ft |
Fibreglass batts, 3 1/2 in (89 mm), for 2×4 cavitiesEW-1, Ground floor, 4 wallsHow
| 10 packages |
Wall sheathing, OSB 7/16 in (11 mm)EW-1, Ground floor, 4 wallsHow
| 33 sheets (4x8 ft) |
House WrapEW-1, Ground floor, 4 wallsHow
| 1 roll |
Vinyl sidingEW-1, Ground floor, 4 wallsHow
| 10.27 squares |
Framing StudIW-1, Ground floor, 2 wallsHow
| 68 studs |
Outlet SpacingIW-1, Ground floor, 2 wallsHow
| 6 outlets (minimum) |
Drywall Joint CompoundIW-1, Ground floor, 2 wallsHowCompound for both faces of the partitions, each door's own area taken off each face.
| 2 x 4.5 gal boxes |
| Material, and where | Quantity |
|---|---|
Flashing tape round the opening, for a timber-framed wallDR-1, Ground floor, 2 openingsHow
| 57.2 ft |
Architrave (casing) inside, two legs and a headDR-1, Ground floor, 2 openingsHow
| 37.4 linear ft |
Mastic (caulk) round the frame, outside and insideDR-1, Ground floor, 2 openingsHow
| 4 tubes |
Paint for the door and frame, both faces: undercoat and glossDR-1, Ground floor, 2 openingsHow
| 0.5269 gal |
Window Opening Flashing MembraneWN-1, Ground floor, 8 openingsHow
| 196.51 ft |
Door & Window CasingWN-1, Ground floor, 8 openingsHow
| 140.78 linear ft |
| Interior doors, 800 × 2000 mm (31 1/2 × 78 3/4 in)counted on the drawing | 5 each |
| Outside doors, 914 × 2134 mm (36 × 84 in)counted on the drawing | 2 each |
| Windows, 1219 × 1219 mm (48 × 48 in)counted on the drawing | 8 each |
| Material, and where | Quantity |
|---|---|
Roofing ShingleRF-1, Ground floorHow
| 16.45 squares |
Roofing UnderlaymentRF-1, Ground floorHow
| 2 rolls |
Roof Eave Ice Dam Protection Membrane Footprint (and Valley Lining)RF-1, Ground floorHow
| 335.18 sq ft |
Roof Ridge CapRF-1, Ground floorHow
| 2 bundles |
Ridge Vent Linear FootageRF-1, Ground floorHow
| 43 ft |
Roof trussesRF-1, Ground floorHow
| 21 trusses |
| Material, and where | Quantity |
|---|---|
Continuous Footing / Grade Beam VolumeFT-1, Ground floorHow
| 7.86 m³ |
Trench Excavation & Backfill VolumeFT-1, Ground floorHow
| 14.35 m³ (loose) |
RebarFT-1, Ground floorHow
| 14 x 12 m sticks |
ConcreteSL-1, Ground floorHow
| 11.88 m³ |
RebarSL-1, Ground floorHow
| 47 x 12 m sticks |
Concrete FormworkSL-1, Ground floorHow
| 20 x 2.4 m boards |
| Material, and where | Quantity |
|---|---|
Studs, 2×4 (38 × 89 mm) at 16 in (400 mm) centresEW-1, Ground floor, 4 wallsHowEach corner is counted on one of its two walls, each partition on the wall it meets; each opening's width is its rough opening, the drawn unit plus 25 mm (1 in) as the window takeoff frames it, each kind's mean on the wall.
| 148 studs |
Plates, headers, sills, cripples, corner and junction studsEW-1, Ground floor, 4 wallsHowEach corner is counted on one of its two walls, each partition on the wall it meets; each opening's width is its rough opening, the drawn unit plus 25 mm (1 in) as the window takeoff frames it, each kind's mean on the wall.
| 184.53 m |
Fibreglass batts, 3 1/2 in (89 mm), for 2×4 cavitiesEW-1, Ground floor, 4 wallsHow
| 10 packages |
Wall sheathing, OSB 7/16 in (11 mm)EW-1, Ground floor, 4 wallsHow
| 33 sheets (2440x1220 mm) |
House WrapEW-1, Ground floor, 4 wallsHow
| 1 roll |
Vinyl sidingEW-1, Ground floor, 4 wallsHow
| 95.81 m² |
Framing StudIW-1, Ground floor, 2 wallsHow
| 66 studs |
Outlet SpacingIW-1, Ground floor, 2 wallsHow
| 6 outlets (minimum) |
Drywall Joint CompoundIW-1, Ground floor, 2 wallsHowCompound for both faces of the partitions, each door's own area taken off each face.
| 46.32 kg |
| Material, and where | Quantity |
|---|---|
Flashing tape round the opening, for a timber-framed wallDR-1, Ground floor, 2 openingsHow
| 17.25 m |
Architrave (casing) inside, two legs and a headDR-1, Ground floor, 2 openingsHow
| 11.26 m |
Mastic (caulk) round the frame, outside and insideDR-1, Ground floor, 2 openingsHow
| 4 tubes |
Paint for the door and frame, both faces: undercoat and glossDR-1, Ground floor, 2 openingsHow
| 1.93 L |
Window Opening Flashing MembraneWN-1, Ground floor, 8 openingsHow
| 58.96 m |
Door & Window CasingWN-1, Ground floor, 8 openingsHow
| 42.24 m |
| Interior doors, 800 × 2000 mm (31 1/2 × 78 3/4 in)counted on the drawing | 5 each |
| Outside doors, 920 × 2100 mm (36 1/4 × 82 3/4 in)counted on the drawing | 2 each |
| Windows, 1200 × 1200 mm (47 1/4 × 47 1/4 in)counted on the drawing | 8 each |
| Material, and where | Quantity |
|---|---|
Roofing ShingleRF-1, Ground floorHow
| 151.86 m² |
Roofing UnderlaymentRF-1, Ground floorHow
| 2 rolls |
Roof Eave Ice Dam Protection Membrane Footprint (and Valley Lining)RF-1, Ground floorHow
| 31.26 m² |
Roof Ridge CapRF-1, Ground floorHow
| 2 bundles |
Ridge Vent Linear FootageRF-1, Ground floorHow
| 13.23 m |
Roof trussesRF-1, Ground floorHow
| 21 trusses |
Example houses
- A ranch for a cold winterOne storey, 2×4 walls, batts, vinyl, ice-dam eaves
- A two-storey house in advanced framing2×6 at 24 in, mineral wool, plywood, fibre cement
- A concrete block house for a hot coastBlock walls, bond beams, a low roof, no ice-dam strip
- A small mountain cabinSpray foam, board and batten, a 12 in 12 roof
- A British timber-frame house140 mm studs, a vapour control layer, larch cladding
- A two-storey block townhouseBlock on both floors, a bond beam at each level
What the figures assume
- Every exterior wall is built as this one type.
- Partitions run across the house, wall to wall, evenly spaced along it.
- The slab covers the whole footprint to the outside faces of the walls.
- The footing runs under the exterior walls' centre line.
- A gable roof with its ridge along the longer side of the footprint.
- Windows are spaced evenly along the walls, with a 900 mm (about 3 ft) sill.
- Window: each rough opening is 25 mm (1 in) bigger than its window each way, the takeoff's own figure.
- Framed exterior wall: the corner count is read only by the plates and headers row, which runs wall by wall.
- Framed exterior wall: the junction count is read only by the plates and headers row, which runs wall by wall.
- Framed exterior wall: the door count is read only by the plates and headers row, which runs wall by wall.
- Framed exterior wall: the windows' width is read only by the plates and headers row, which runs wall by wall.
- Framed exterior wall: the doors' width is read only by the plates and headers row, which runs wall by wall.
- Stud partition: each door's own area already comes off both faces in the length; the takeoff's flat allowance a door would take it off twice.
- Outside door: one row of the takeoff is left out, protecting an occupied house's floors while an old door comes out; a new house has no finished floor at that stage.
- Outside door: one row of the takeoff is left out, the waste of the old door and frame; a new door replaces nothing.
- Window: one row of the takeoff is left out, a saving against an old window's U-factor; a new house has no old window to compare.
- An interior door is counted; its casing is a planned assembly.
- Each corner is counted on one of its two walls, each partition on the wall it meets; each opening's width is its rough opening, the drawn unit plus 25 mm (1 in) as the window takeoff frames it, each kind's mean on the wall.
- Openings are not deducted from this row: the boards round a door or window are cut from full-height boards, so the count is across the whole outside face.
- Compound for both faces of the partitions, each door's own area taken off each face.
- Every exterior wall is built as this one type.
- Partitions run across the house, wall to wall, evenly spaced along it.
- The slab covers the whole footprint to the outside faces of the walls.
- The footing runs under the exterior walls' centre line.
- A gable roof with its ridge along the longer side of the footprint.
- Windows are spaced evenly along the walls, with a 900 mm (about 3 ft) sill.
- Window: each rough opening is 25 mm (1 in) bigger than its window each way, the takeoff's own figure.
- Framed exterior wall: the corner count is read only by the plates and headers row, which runs wall by wall.
- Framed exterior wall: the junction count is read only by the plates and headers row, which runs wall by wall.
- Framed exterior wall: the door count is read only by the plates and headers row, which runs wall by wall.
- Framed exterior wall: the windows' width is read only by the plates and headers row, which runs wall by wall.
- Framed exterior wall: the doors' width is read only by the plates and headers row, which runs wall by wall.
- Stud partition: each door's own area already comes off both faces in the length; the takeoff's flat allowance a door would take it off twice.
- Outside door: one row of the takeoff is left out, protecting an occupied house's floors while an old door comes out; a new house has no finished floor at that stage.
- Outside door: one row of the takeoff is left out, the waste of the old door and frame; a new door replaces nothing.
- Window: one row of the takeoff is left out, a saving against an old window's U-factor; a new house has no old window to compare.
- An interior door is counted; its casing is a planned assembly.
- Each corner is counted on one of its two walls, each partition on the wall it meets; each opening's width is its rough opening, the drawn unit plus 25 mm (1 in) as the window takeoff frames it, each kind's mean on the wall.
- Openings are not deducted from this row: the boards round a door or window are cut from full-height boards, so the count is across the whole outside face.
- Compound for both faces of the partitions, each door's own area taken off each face.
This page counts materials; it does not check strength. Stud sizes, spacings, footings and the slab are taken as you set them, never sized or approved for a load.
How it counts
- Type the outside length and width of the house, the storeys and the storey height.
- Choose the exterior wall and its build-up, the roof pitch and the foundation figures.
- Set the partitions, doors and windows; the plan and the list follow.
- Open any row's working, then send the list to My Project to put your own rates on it.
The takeoffs it runs
The calculators behind the rows
- Continuous Footing / Grade Beam Volume Calculator
- Trench Excavation & Backfill Volume Calculator
- Rebar Calculator
- Concrete Calculator
- Concrete Formwork Calculator
- Framing Stud Calculator
- Wall Plates, Headers and Cripples Calculator (Sole Plate, Head Binder, Lintel and Corner Studs)
- Insulation Batt Calculator
- Plywood and OSB Sheet Calculator (Subfloor, Wall and Roof)
- House Wrap Calculator
- Siding Calculator
- Outlet Spacing Calculator
- Drywall Joint Compound Calculator
- Window Opening Flashing Membrane Calculator
- Door & Window Casing Calculator
- Caulk & Sealant Calculator
- Woodwork Paint Calculator
- Roofing Shingle Calculator
- Roofing Underlayment Calculator
- Roof Eave Ice Dam Protection Membrane Footprint (and Valley Lining)
- Roof Ridge Cap Calculator
- Ridge Vent Linear Footage Calculator
- Roof Truss Spacing & Count Calculator
The takeoffs it runs
The calculators behind the rows
- Continuous Footing / Grade Beam Volume Calculator
- Trench Excavation & Backfill Volume Calculator
- Rebar Calculator
- Concrete Calculator
- Concrete Formwork Calculator
- Framing Stud Calculator
- Wall Plates, Headers and Cripples Calculator (Sole Plate, Head Binder, Lintel and Corner Studs)
- Insulation Batt Calculator
- Plywood and OSB Sheet Calculator (Subfloor, Wall and Roof)
- House Wrap Calculator
- Siding Calculator
- Outlet Spacing Calculator
- Drywall Joint Compound Calculator
- Window Opening Flashing Membrane Calculator
- Door & Window Casing Calculator
- Caulk & Sealant Calculator
- Woodwork Paint Calculator
- Roofing Shingle Calculator
- Roofing Underlayment Calculator
- Roof Eave Ice Dam Protection Membrane Footprint (and Valley Lining)
- Roof Ridge Cap Calculator
- Ridge Vent Linear Footage Calculator
- Roof Truss Spacing & Count Calculator
Read before you order
Questions
- What does the House Estimator count?
- The structure and the shell of a rectangular house: the concrete, reinforcement and backfill of a strip footing, the slab, the exterior walls (framed or masonry, layer by layer), the interior partitions, the windows and outside doors with their flashing and casing, and an asphalt shingle roof. Each quantity comes from one of the site's whole-job takeoffs, run on the measurements the drawing gives it.
- Are doors and windows taken off the walls?
- Yes. Every opening's own width and height come off each face it passes through, and once off the wall's core. The stud count gets the extra studs each opening takes, wall by wall. The single-wall takeoff pages work on the gross wall; here the drawing knows where each opening is, so it deducts them.
- Why are the studs counted wall by wall but the sheathing for the whole house?
- A stud count rounds up along one straight run, and its calculator takes one wall at a time, so each wall is counted on its own. Sheathing, wrap, insulation and cladding are bought by area: they are worked out once for all the walls of one build-up, height and storey, so the rounding happens once instead of once per wall.
- Does it work out costs?
- No. It gives quantities and planning hours. Send the list to My Project and put your own supplier's rates on the lines there; the site never supplies a rate of its own.
- Can I trust it for structure?
- It counts; it does not design. Stud size and spacing, the footing, the slab and the roof pitch are taken as you enter them and are never checked against a load, a span or a code. A structural engineer or your building official decides those.