Every material for a new house
Six steps; drawn, measured wall by wall, every material listed.
- Footprint, outside
- 39' 0" × 30' 0"12.00 m × 9.00 m11.89 m × 9.14 m39' 4 1/2" × 29' 6 1/4"
- Floor area, gross
- 1170.0 sq ft108.00 m²108.69 m²1162.5 sq ft
- Storeys
- 1storeys of 8' 0"storeys of 2.44 m
- Windows and doors
- 108 windows, 2 doors
- Rows to buy
- 30quantities, never prices
Everything to buy
Quantities to order, with each calculator’s own waste. Your own rates go on the lines in My Project.
Foundation and floor
| Material, and where | Quantity |
|---|---|
FT-1, Ground floorHow
| 10.4 yd³ |
FT-1, Ground floorHow
| 19.69 yd³ |
FT-1, Ground floorHow
| 27 x 20 ft sticks |
SL-1, Ground floorHow
| 15.95 yd³ |
SL-1, Ground floorHow
| 92 x 20 ft sticks |
SL-1, Ground floorHow
| 19 x 8 ft boards |
Walls
| Material, and where | Quantity |
|---|---|
EW-1, Ground floor, 4 wallsHowEach corner is counted on one of its two walls, each partition on the wall it meets; each opening's width is its rough opening, the drawn unit plus 25 mm (1 in) as the window takeoff frames it, each kind's mean on the wall.
| 166 studs |
EW-1, Ground floor, 4 wallsHowEach corner is counted on one of its two walls, each partition on the wall it meets; each opening's width is its rough opening, the drawn unit plus 25 mm (1 in) as the window takeoff frames it, each kind's mean on the wall.
| 604.24 ft |
EW-1, Ground floor, 4 wallsHow
| 10 packages |
EW-1, Ground floor, 4 wallsHow
| 33 sheets (4x8 ft) |
EW-1, Ground floor, 4 wallsHow
| 1 roll |
EW-1, Ground floor, 4 wallsHow
| 10.27 squares |
IW-1, Ground floor, 2 wallsHow
| 76 studs |
IW-1, Ground floor, 2 wallsHow
| 6 outlets (minimum) |
IW-1, Ground floor, 2 wallsHowCompound for both faces of the partitions, each door's own area taken off each face.
| 2 x 4.5 gal boxes |
Doors and windows
| Material, and where | Quantity |
|---|---|
DR-1, Ground floor, 2 openingsHow
| 57.2 ft |
DR-1, Ground floor, 2 openingsHow
| 37.4 linear ft |
DR-1, Ground floor, 2 openingsHow
| 4 tubes |
DR-1, Ground floor, 2 openingsHow
| 0.5269 gal |
WN-1, Ground floor, 8 openingsHow
| 196.51 ft |
WN-1, Ground floor, 8 openingsHow
| 140.78 linear ft |
| Interior doors, 800 × 2000 mm (31 1/2 × 78 3/4 in)counted on the drawing | 5 each |
| Outside doors, 914 × 2134 mm (36 × 84 in)counted on the drawing | 2 each |
| Windows, 1219 × 1219 mm (48 × 48 in)counted on the drawing | 8 each |
Roof
| Material, and where | Quantity |
|---|---|
RF-1, Ground floorHow
| 16.45 squares |
RF-1, Ground floorHow
| 2 rolls |
RF-1, Ground floorHow
| 335.18 sq ft |
RF-1, Ground floorHow
| 2 bundles |
RF-1, Ground floorHow
| 43 ft |
RF-1, Ground floorHow
| 21 trusses |
Foundation and floor
| Material, and where | Quantity |
|---|---|
FT-1, Ground floorHow
| 7.86 m³ |
FT-1, Ground floorHow
| 14.35 m³ (loose) |
FT-1, Ground floorHow
| 14 x 12 m sticks |
SL-1, Ground floorHow
| 11.88 m³ |
SL-1, Ground floorHow
| 47 x 12 m sticks |
SL-1, Ground floorHow
| 20 x 2.4 m boards |
Walls
| Material, and where | Quantity |
|---|---|
EW-1, Ground floor, 4 wallsHowEach corner is counted on one of its two walls, each partition on the wall it meets; each opening's width is its rough opening, the drawn unit plus 25 mm (1 in) as the window takeoff frames it, each kind's mean on the wall.
| 164 studs |
EW-1, Ground floor, 4 wallsHowEach corner is counted on one of its two walls, each partition on the wall it meets; each opening's width is its rough opening, the drawn unit plus 25 mm (1 in) as the window takeoff frames it, each kind's mean on the wall.
| 184.53 m |
EW-1, Ground floor, 4 wallsHow
| 10 packages |
EW-1, Ground floor, 4 wallsHow
| 33 sheets (2440x1220 mm) |
EW-1, Ground floor, 4 wallsHow
| 1 roll |
EW-1, Ground floor, 4 wallsHow
| 95.81 m² |
IW-1, Ground floor, 2 wallsHow
| 74 studs |
IW-1, Ground floor, 2 wallsHow
| 6 outlets (minimum) |
IW-1, Ground floor, 2 wallsHowCompound for both faces of the partitions, each door's own area taken off each face.
| 46.32 kg |
Doors and windows
| Material, and where | Quantity |
|---|---|
DR-1, Ground floor, 2 openingsHow
| 17.25 m |
DR-1, Ground floor, 2 openingsHow
| 11.26 m |
DR-1, Ground floor, 2 openingsHow
| 4 tubes |
DR-1, Ground floor, 2 openingsHow
| 1.93 L |
WN-1, Ground floor, 8 openingsHow
| 58.96 m |
WN-1, Ground floor, 8 openingsHow
| 42.24 m |
| Interior doors, 800 × 2000 mm (31 1/2 × 78 3/4 in)counted on the drawing | 5 each |
| Outside doors, 920 × 2100 mm (36 1/4 × 82 3/4 in)counted on the drawing | 2 each |
| Windows, 1200 × 1200 mm (47 1/4 × 47 1/4 in)counted on the drawing | 8 each |
Roof
| Material, and where | Quantity |
|---|---|
RF-1, Ground floorHow
| 151.86 m² |
RF-1, Ground floorHow
| 2 rolls |
RF-1, Ground floorHow
| 31.26 m² |
RF-1, Ground floorHow
| 2 bundles |
RF-1, Ground floorHow
| 13.23 m |
RF-1, Ground floorHow
| 21 trusses |
Variants
Keep this house under a name, change it, keep that too, and compare any two: their figures and their bills, row by row.
Example houses
A ranch for a cold winterOne storey, 2×4 walls, batts, vinyl, ice-dam eaves
A two-storey house in advanced framing2×6 at 24 in, mineral wool, plywood, fibre cement
A concrete block house for a hot coastBlock walls, bond beams, a low roof, no ice-dam strip
A small mountain cabinSpray foam, board and batten, a 12 in 12 roof
A British timber-frame house140 mm studs, a vapour control layer, larch cladding
A two-storey block townhouseBlock on both floors, a bond beam at each level
What the figures assume
- Every exterior wall is built as this one type.
- Partitions run across the house, wall to wall, evenly spaced along it.
- The slab covers the whole footprint to the outside faces of the walls.
- The footing runs under the exterior walls' centre line.
- A gable roof with its ridge along the longer side of the footprint.
Show all 20 assumptions
- Windows are spaced evenly along the walls, with a 900 mm (about 3 ft) sill.
- Window: each rough opening is 25 mm (1 in) bigger than its window each way, the takeoff's own figure.
- Framed exterior wall: the corner count is read only by the plates and headers row, which runs wall by wall.
- Framed exterior wall: the junction count is read only by the plates and headers row, which runs wall by wall.
- Framed exterior wall: the door count is read only by the plates and headers row, which runs wall by wall.
- Framed exterior wall: the windows' width is read only by the plates and headers row, which runs wall by wall.
- Framed exterior wall: the doors' width is read only by the plates and headers row, which runs wall by wall.
- Stud partition: each door's own area already comes off both faces in the length; the takeoff's flat allowance a door would take it off twice.
- Outside door: one row of the takeoff is left out, protecting an occupied house's floors while an old door comes out; a new house has no finished floor at that stage.
- Outside door: one row of the takeoff is left out, the waste of the old door and frame; a new door replaces nothing.
- Window: one row of the takeoff is left out, a saving against an old window's U-factor; a new house has no old window to compare.
- An interior door is counted; its casing is a planned assembly.
- Each corner is counted on one of its two walls, each partition on the wall it meets; each opening's width is its rough opening, the drawn unit plus 25 mm (1 in) as the window takeoff frames it, each kind's mean on the wall.
- Openings are not deducted from this row: the boards round a door or window are cut from full-height boards, so the count is across the whole outside face.
- Compound for both faces of the partitions, each door's own area taken off each face.
- Every exterior wall is built as this one type.
- Partitions run across the house, wall to wall, evenly spaced along it.
- The slab covers the whole footprint to the outside faces of the walls.
- The footing runs under the exterior walls' centre line.
- A gable roof with its ridge along the longer side of the footprint.
Show all 20 assumptions
- Windows are spaced evenly along the walls, with a 900 mm (about 3 ft) sill.
- Window: each rough opening is 25 mm (1 in) bigger than its window each way, the takeoff's own figure.
- Framed exterior wall: the corner count is read only by the plates and headers row, which runs wall by wall.
- Framed exterior wall: the junction count is read only by the plates and headers row, which runs wall by wall.
- Framed exterior wall: the door count is read only by the plates and headers row, which runs wall by wall.
- Framed exterior wall: the windows' width is read only by the plates and headers row, which runs wall by wall.
- Framed exterior wall: the doors' width is read only by the plates and headers row, which runs wall by wall.
- Stud partition: each door's own area already comes off both faces in the length; the takeoff's flat allowance a door would take it off twice.
- Outside door: one row of the takeoff is left out, protecting an occupied house's floors while an old door comes out; a new house has no finished floor at that stage.
- Outside door: one row of the takeoff is left out, the waste of the old door and frame; a new door replaces nothing.
- Window: one row of the takeoff is left out, a saving against an old window's U-factor; a new house has no old window to compare.
- An interior door is counted; its casing is a planned assembly.
- Each corner is counted on one of its two walls, each partition on the wall it meets; each opening's width is its rough opening, the drawn unit plus 25 mm (1 in) as the window takeoff frames it, each kind's mean on the wall.
- Openings are not deducted from this row: the boards round a door or window are cut from full-height boards, so the count is across the whole outside face.
- Compound for both faces of the partitions, each door's own area taken off each face.
This page counts materials; it does not check strength. Stud sizes, spacings, footings and the slab are taken as you set them, never sized or approved for a load.
How it counts
- Give the footprint and the foundation, then the storeys and their height.
- Choose the exterior wall and its frame, the doors and windows, and the roof.
- Choose the finishes on the walls; the plan, the elevations and the list follow every step.
- Open any row's working, group or export the list, then send it to My Project for your own rates, or open the house in the canvas.
The takeoffs it runs
The calculators behind the rows
- Continuous Footing / Grade Beam Volume Calculator
- Trench Excavation & Backfill Volume Calculator
- Rebar Calculator
- Concrete Calculator
- Concrete Formwork Calculator
- Framing Stud Calculator
- Wall Plates, Headers and Cripples Calculator (Sole Plate, Head Binder, Lintel and Corner Studs)
- Insulation Batt Calculator
- Plywood and OSB Sheet Calculator (Subfloor, Wall and Roof)
- House Wrap Calculator
- Siding Calculator
- Outlet Spacing Calculator
- Drywall Joint Compound Calculator
- Window Opening Flashing Membrane Calculator
- Door & Window Casing Calculator
- Caulk & Sealant Calculator
- Woodwork Paint Calculator
- Roofing Shingle Calculator
- Roofing Underlayment Calculator
- Roof Eave Ice Dam Protection Membrane Footprint (and Valley Lining)
- Roof Ridge Cap Calculator
- Ridge Vent Linear Footage Calculator
- Roof Truss Spacing & Count Calculator
The takeoffs it runs
The calculators behind the rows
- Continuous Footing / Grade Beam Volume Calculator
- Trench Excavation & Backfill Volume Calculator
- Rebar Calculator
- Concrete Calculator
- Concrete Formwork Calculator
- Framing Stud Calculator
- Wall Plates, Headers and Cripples Calculator (Sole Plate, Head Binder, Lintel and Corner Studs)
- Insulation Batt Calculator
- Plywood and OSB Sheet Calculator (Subfloor, Wall and Roof)
- House Wrap Calculator
- Siding Calculator
- Outlet Spacing Calculator
- Drywall Joint Compound Calculator
- Window Opening Flashing Membrane Calculator
- Door & Window Casing Calculator
- Caulk & Sealant Calculator
- Woodwork Paint Calculator
- Roofing Shingle Calculator
- Roofing Underlayment Calculator
- Roof Eave Ice Dam Protection Membrane Footprint (and Valley Lining)
- Roof Ridge Cap Calculator
- Ridge Vent Linear Footage Calculator
- Roof Truss Spacing & Count Calculator
Read before you order
Questions
- What does the House Estimator count?
- The structure and the shell of a rectangular house: the concrete, reinforcement and backfill of a strip footing, the slab, the exterior walls (framed or masonry, layer by layer), the interior partitions, the windows and outside doors with their flashing and casing, and an asphalt shingle roof. Each quantity comes from one of the site's whole-job takeoffs, run on the measurements the drawing gives it.
- Are doors and windows taken off the walls?
- Yes. Every opening's own width and height come off each face it passes through, and once off the wall's core. The stud count gets the extra studs each opening takes, wall by wall. The single-wall takeoff pages work on the gross wall; here the drawing knows where each opening is, so it deducts them.
- Why are the studs counted wall by wall but the sheathing for the whole house?
- A stud count rounds up along one straight run, and its calculator takes one wall at a time, so each wall is counted on its own. Sheathing, wrap, insulation and cladding are bought by area: they are worked out once for all the walls of one build-up, height and storey, so the rounding happens once instead of once per wall.
- Are the elevations and the 3D view the same as the Construction Canvas's?
- Yes. The house is a canvas drawing, and the front and side elevations and the 3D model on this page are drawn by the canvas's own views from that drawing, with the same wall thicknesses. Open in Canvas carries the same drawing over, to change it wall by wall.
- Can the house be an L, T or U shape, with rooms and a stair?
- Yes. Edit the plan to draw the footprint as an L, a T or a U, drag or type each side, draw the inside walls that make the rooms and name them, place each door and window, add storeys of their own heights and a stair, and choose a gable, hip or shed roof. The same takeoffs count the drawn house, storey by storey and room by room, and Open in Canvas carries every level and room over.
- Does it work out costs?
- No. It gives quantities and planning hours. Send the list to My Project and put your own supplier's rates on the lines there; the site never supplies a rate of its own.
- Can I trust it for structure?
- It counts; it does not design. Stud size and spacing, the footing, the slab and the roof pitch are taken as you enter them and are never checked against a load, a span or a code. A structural engineer or your building official decides those.