House estimator

Every material for a new house

Give the footprint, the storeys, the walls, the roof and the openings. The house is drawn, measured wall by wall and run through the site’s own takeoffs, with each door and window taken off the faces it passes through, so the list below is what to order, with the working behind every line.
  • 30Rows for this house
  • Openings deductedWall by wall
  • Planning hoursHours, not money
Plan of a one-storey house 39 ft by 30 ft outside, with 8 windows and 7 doors in all. Ground floor.39 ft11.89 m30 ft9.14 m
Ground floor: walls to scale, each opening where the drawing put it.
Plan of a one-storey house 12 m by 9 m outside, with 8 windows and 7 doors in all. Ground floor.39.37 ft12 m29.53 ft9 m
Ground floor: walls to scale, each opening where the drawing put it.

Everything to buy

Quantities to order, with each calculator’s own waste. Your own rates go on the lines in My Project.

Foundation and floor
Material, and whereQuantity
Continuous Footing / Grade Beam VolumeFT-1, Ground floor
How
10.4 yd³
Trench Excavation & Backfill VolumeFT-1, Ground floor
How
19.69 yd³
RebarFT-1, Ground floor
How
27 x 20 ft sticks
ConcreteSL-1, Ground floor
How
15.95 yd³
RebarSL-1, Ground floor
How
92 x 20 ft sticks
Concrete FormworkSL-1, Ground floor
How
19 x 8 ft boards
Walls
Material, and whereQuantity
Studs, 2×4 (38 × 89 mm) at 16 in (400 mm) centresEW-1, Ground floor, 4 walls
How

Each corner is counted on one of its two walls, each partition on the wall it meets; each opening's width is its rough opening, the drawn unit plus 25 mm (1 in) as the window takeoff frames it, each kind's mean on the wall.

150 studs
Plates, headers, sills, cripples, corner and junction studsEW-1, Ground floor, 4 walls
How

Each corner is counted on one of its two walls, each partition on the wall it meets; each opening's width is its rough opening, the drawn unit plus 25 mm (1 in) as the window takeoff frames it, each kind's mean on the wall.

604.24 ft
Fibreglass batts, 3 1/2 in (89 mm), for 2×4 cavitiesEW-1, Ground floor, 4 walls
How
10 packages
Wall sheathing, OSB 7/16 in (11 mm)EW-1, Ground floor, 4 walls
How
33 sheets (4x8 ft)
House WrapEW-1, Ground floor, 4 walls
How
1 roll
Vinyl sidingEW-1, Ground floor, 4 walls
How
10.27 squares
Framing StudIW-1, Ground floor, 2 walls
How
68 studs
Outlet SpacingIW-1, Ground floor, 2 walls
How
6 outlets (minimum)
Drywall Joint CompoundIW-1, Ground floor, 2 walls
How

Compound for both faces of the partitions, each door's own area taken off each face.

2 x 4.5 gal boxes
Doors and windows
Material, and whereQuantity
Flashing tape round the opening, for a timber-framed wallDR-1, Ground floor, 2 openings
How
57.2 ft
Architrave (casing) inside, two legs and a headDR-1, Ground floor, 2 openings
How
37.4 linear ft
Mastic (caulk) round the frame, outside and insideDR-1, Ground floor, 2 openings
How
4 tubes
Paint for the door and frame, both faces: undercoat and glossDR-1, Ground floor, 2 openings
How
0.5269 gal
Window Opening Flashing MembraneWN-1, Ground floor, 8 openings
How
196.51 ft
Door & Window CasingWN-1, Ground floor, 8 openings
How
140.78 linear ft
Interior doors, 800 × 2000 mm (31 1/2 × 78 3/4 in)counted on the drawing5 each
Outside doors, 914 × 2134 mm (36 × 84 in)counted on the drawing2 each
Windows, 1219 × 1219 mm (48 × 48 in)counted on the drawing8 each
Roof
Material, and whereQuantity
Roofing ShingleRF-1, Ground floor
How
16.45 squares
Roofing UnderlaymentRF-1, Ground floor
How
2 rolls
Roof Eave Ice Dam Protection Membrane Footprint (and Valley Lining)RF-1, Ground floor
How
335.18 sq ft
Roof Ridge CapRF-1, Ground floor
How
2 bundles
Ridge Vent Linear FootageRF-1, Ground floor
How
43 ft
Roof trussesRF-1, Ground floor
How
21 trusses
Foundation and floor
Material, and whereQuantity
Continuous Footing / Grade Beam VolumeFT-1, Ground floor
How
7.86 m³
Trench Excavation & Backfill VolumeFT-1, Ground floor
How
14.35 m³ (loose)
RebarFT-1, Ground floor
How
14 x 12 m sticks
ConcreteSL-1, Ground floor
How
11.88 m³
RebarSL-1, Ground floor
How
47 x 12 m sticks
Concrete FormworkSL-1, Ground floor
How
20 x 2.4 m boards
Walls
Material, and whereQuantity
Studs, 2×4 (38 × 89 mm) at 16 in (400 mm) centresEW-1, Ground floor, 4 walls
How

Each corner is counted on one of its two walls, each partition on the wall it meets; each opening's width is its rough opening, the drawn unit plus 25 mm (1 in) as the window takeoff frames it, each kind's mean on the wall.

148 studs
Plates, headers, sills, cripples, corner and junction studsEW-1, Ground floor, 4 walls
How

Each corner is counted on one of its two walls, each partition on the wall it meets; each opening's width is its rough opening, the drawn unit plus 25 mm (1 in) as the window takeoff frames it, each kind's mean on the wall.

184.53 m
Fibreglass batts, 3 1/2 in (89 mm), for 2×4 cavitiesEW-1, Ground floor, 4 walls
How
10 packages
Wall sheathing, OSB 7/16 in (11 mm)EW-1, Ground floor, 4 walls
How
33 sheets (2440x1220 mm)
House WrapEW-1, Ground floor, 4 walls
How
1 roll
Vinyl sidingEW-1, Ground floor, 4 walls
How
95.81 m²
Framing StudIW-1, Ground floor, 2 walls
How
66 studs
Outlet SpacingIW-1, Ground floor, 2 walls
How
6 outlets (minimum)
Drywall Joint CompoundIW-1, Ground floor, 2 walls
How

Compound for both faces of the partitions, each door's own area taken off each face.

46.32 kg
Doors and windows
Material, and whereQuantity
Flashing tape round the opening, for a timber-framed wallDR-1, Ground floor, 2 openings
How
17.25 m
Architrave (casing) inside, two legs and a headDR-1, Ground floor, 2 openings
How
11.26 m
Mastic (caulk) round the frame, outside and insideDR-1, Ground floor, 2 openings
How
4 tubes
Paint for the door and frame, both faces: undercoat and glossDR-1, Ground floor, 2 openings
How
1.93 L
Window Opening Flashing MembraneWN-1, Ground floor, 8 openings
How
58.96 m
Door & Window CasingWN-1, Ground floor, 8 openings
How
42.24 m
Interior doors, 800 × 2000 mm (31 1/2 × 78 3/4 in)counted on the drawing5 each
Outside doors, 920 × 2100 mm (36 1/4 × 82 3/4 in)counted on the drawing2 each
Windows, 1200 × 1200 mm (47 1/4 × 47 1/4 in)counted on the drawing8 each
Roof
Material, and whereQuantity
Roofing ShingleRF-1, Ground floor
How
151.86 m²
Roofing UnderlaymentRF-1, Ground floor
How
2 rolls
Roof Eave Ice Dam Protection Membrane Footprint (and Valley Lining)RF-1, Ground floor
How
31.26 m²
Roof Ridge CapRF-1, Ground floor
How
2 bundles
Ridge Vent Linear FootageRF-1, Ground floor
How
13.23 m
Roof trussesRF-1, Ground floor
How
21 trusses

Example houses

What the figures assume

  • Every exterior wall is built as this one type.
  • Partitions run across the house, wall to wall, evenly spaced along it.
  • The slab covers the whole footprint to the outside faces of the walls.
  • The footing runs under the exterior walls' centre line.
  • A gable roof with its ridge along the longer side of the footprint.
  • Windows are spaced evenly along the walls, with a 900 mm (about 3 ft) sill.
  • Window: each rough opening is 25 mm (1 in) bigger than its window each way, the takeoff's own figure.
  • Framed exterior wall: the corner count is read only by the plates and headers row, which runs wall by wall.
  • Framed exterior wall: the junction count is read only by the plates and headers row, which runs wall by wall.
  • Framed exterior wall: the door count is read only by the plates and headers row, which runs wall by wall.
  • Framed exterior wall: the windows' width is read only by the plates and headers row, which runs wall by wall.
  • Framed exterior wall: the doors' width is read only by the plates and headers row, which runs wall by wall.
  • Stud partition: each door's own area already comes off both faces in the length; the takeoff's flat allowance a door would take it off twice.
  • Outside door: one row of the takeoff is left out, protecting an occupied house's floors while an old door comes out; a new house has no finished floor at that stage.
  • Outside door: one row of the takeoff is left out, the waste of the old door and frame; a new door replaces nothing.
  • Window: one row of the takeoff is left out, a saving against an old window's U-factor; a new house has no old window to compare.
  • An interior door is counted; its casing is a planned assembly.
  • Each corner is counted on one of its two walls, each partition on the wall it meets; each opening's width is its rough opening, the drawn unit plus 25 mm (1 in) as the window takeoff frames it, each kind's mean on the wall.
  • Openings are not deducted from this row: the boards round a door or window are cut from full-height boards, so the count is across the whole outside face.
  • Compound for both faces of the partitions, each door's own area taken off each face.
  • Every exterior wall is built as this one type.
  • Partitions run across the house, wall to wall, evenly spaced along it.
  • The slab covers the whole footprint to the outside faces of the walls.
  • The footing runs under the exterior walls' centre line.
  • A gable roof with its ridge along the longer side of the footprint.
  • Windows are spaced evenly along the walls, with a 900 mm (about 3 ft) sill.
  • Window: each rough opening is 25 mm (1 in) bigger than its window each way, the takeoff's own figure.
  • Framed exterior wall: the corner count is read only by the plates and headers row, which runs wall by wall.
  • Framed exterior wall: the junction count is read only by the plates and headers row, which runs wall by wall.
  • Framed exterior wall: the door count is read only by the plates and headers row, which runs wall by wall.
  • Framed exterior wall: the windows' width is read only by the plates and headers row, which runs wall by wall.
  • Framed exterior wall: the doors' width is read only by the plates and headers row, which runs wall by wall.
  • Stud partition: each door's own area already comes off both faces in the length; the takeoff's flat allowance a door would take it off twice.
  • Outside door: one row of the takeoff is left out, protecting an occupied house's floors while an old door comes out; a new house has no finished floor at that stage.
  • Outside door: one row of the takeoff is left out, the waste of the old door and frame; a new door replaces nothing.
  • Window: one row of the takeoff is left out, a saving against an old window's U-factor; a new house has no old window to compare.
  • An interior door is counted; its casing is a planned assembly.
  • Each corner is counted on one of its two walls, each partition on the wall it meets; each opening's width is its rough opening, the drawn unit plus 25 mm (1 in) as the window takeoff frames it, each kind's mean on the wall.
  • Openings are not deducted from this row: the boards round a door or window are cut from full-height boards, so the count is across the whole outside face.
  • Compound for both faces of the partitions, each door's own area taken off each face.

This page counts materials; it does not check strength. Stud sizes, spacings, footings and the slab are taken as you set them, never sized or approved for a load.

How it counts

  1. Type the outside length and width of the house, the storeys and the storey height.
  2. Choose the exterior wall and its build-up, the roof pitch and the foundation figures.
  3. Set the partitions, doors and windows; the plan and the list follow.
  4. Open any row's working, then send the list to My Project to put your own rates on it.

Read before you order

Questions

What does the House Estimator count?
The structure and the shell of a rectangular house: the concrete, reinforcement and backfill of a strip footing, the slab, the exterior walls (framed or masonry, layer by layer), the interior partitions, the windows and outside doors with their flashing and casing, and an asphalt shingle roof. Each quantity comes from one of the site's whole-job takeoffs, run on the measurements the drawing gives it.
Are doors and windows taken off the walls?
Yes. Every opening's own width and height come off each face it passes through, and once off the wall's core. The stud count gets the extra studs each opening takes, wall by wall. The single-wall takeoff pages work on the gross wall; here the drawing knows where each opening is, so it deducts them.
Why are the studs counted wall by wall but the sheathing for the whole house?
A stud count rounds up along one straight run, and its calculator takes one wall at a time, so each wall is counted on its own. Sheathing, wrap, insulation and cladding are bought by area: they are worked out once for all the walls of one build-up, height and storey, so the rounding happens once instead of once per wall.
Does it work out costs?
No. It gives quantities and planning hours. Send the list to My Project and put your own supplier's rates on the lines there; the site never supplies a rate of its own.
Can I trust it for structure?
It counts; it does not design. Stud size and spacing, the footing, the slab and the roof pitch are taken as you enter them and are never checked against a load, a span or a code. A structural engineer or your building official decides those.