SettingsSettings for this calculationUS
The standard allowance most suppliers and estimating guides assume for ordinary work.
The length of the wall, floor, or attic area to insulate.
Measure the space you're insulating — an attic floor, a wall run, or a ceiling.
Tools needed: Tape measure
The width of the area to insulate.
Measure perpendicular to the length.
Tools needed: Tape measure
The square footage one package covers, printed on the product label.
This varies significantly by R-value, thickness, and brand — check your specific product's packaging rather than relying on a generic default.
Extra material for cuts around obstructions (pipes, wiring, joists).
10% is standard for a straightforward area. Attics with lots of framing members and obstructions may need more.
The rated R-value printed on the first layer's pack; 0 leaves the R rows out.
An R-13 wall batt is about 2.29 m²K/W, R-19 about 3.35, R-30 about 5.28. The page adds the layers' ratings and no more; it does not count the framing, which conducts more heat than the batt beside it.
The rated R-value of a second layer laid over the first, such as a cross layer in a loft; 0 for none.
Layers in series add: R-13 under R-19 gives R-32. Run the package count once for each layer, since each has its own coverage per pack.
Estimated insulation batt needed
12 packages
- Area to insulate
- 1,014 sq ft
- Area with waste factor
- 1,115.4 sq ft
Formula with your numbers
- Measure the area × = 1,014 sq ft
- Add the waste allowance1,014 sq ft + % waste = 1,115.4 sq ft
- Divide by one package and round up1,115.4 sq ft ÷ a package, rounded up = 12 packages
They open the calculator with your figures already in it
Insulation Batt Calculator: 12 packages — shown in imperial, US market. The link sets both, so the result they see is the one on your screen.
Show calculation logicHide calculation logic
How this was calculated
Formula source(s)
- Batt/roll insulation coverage per package varies by R-value, thickness, and brand — always use the square footage printed on your specific product's packaging for an accurate count
Inputs used
- Area Length
- 39 ft
- Area Width
- 26 ft
- Package coverage
- 100 sq ft
- Waste Factor (%)
- 10
- First Layer R-Value
- 0 hr·ft²·°F/BTU
- Second Layer R-Value
- 0 hr·ft²·°F/BTU
Intermediate steps
- Area to insulate
- 1,014 sq ft
- Area with waste factor
- 1,115.4 sq ft
What this calculation does not cover
- This counts area against the coverage printed on your package. It does not check that the batt width suits your framing spacing or that the batt thickness fits the cavity depth — a 16 in (406 mm) batt in bays framed at 24 in (610 mm) centres leaves gaps that no package count corrects.
- The R-value rows only add the rated R-values of the layers you enter, as layers in series do; they never enter the package count. Nothing here tests the finished assembly against the R-value your climate zone and local code call for, and no allowance is made for heat flow through the framing members themselves, which conduct more than the cavity beside them.
- The area is the plain rectangle you enter. Nothing is deducted for windows, doors or the attic hatch, and nothing is set aside for the areas that must stay clear — recessed lights, flues and chimneys, and the eave gap soffit ventilation needs. Those clearances come from the manufacturer's instructions and local code, not from this count.
- The waste factor is a flat percentage of the whole area, not a cutting plan. Irregular bays, hips and valleys, and heavily obstructed framing produce short offcuts that waste far more than a percentage of the total suggests.
- This is a purchase quantity, not an energy or compliance calculation. It says nothing about air sealing — batts do not stop air leakage — nor about which way a faced batt's vapour retarder must face, which depends on your climate.
Estimated cost — your price
This site holds no price list for this material — local prices vary too much to publish honestly. Enter your supplier's price and the result is costed with it.
Part of bigger jobs
This trade is one line of several job takeoffs. Run the whole job and every other trade comes back with it, off the same measurements.
Or plan the space itself: measure it once, doors and windows included, and this figure comes back worked out on that space, with what goes with it.
also measures18 other trades
also measuresAttic Insulation Upgrade
also measuresFraming StudWall Plates, Headers and Cripples (Sole Plate, Head Binder, Lintel and Corner Studs)Plywood and OSB Sheet (Subfloor, Wall and Roof)House WrapSiding
Computed in your browser — nothing you enter is uploaded. Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.
Sources checked 2026-10-31 · 3 test vectors · v1.1.0
Regulatory standards & verification citations1
- Batt/roll insulation coverage per package varies by R-value, thickness, and brand — always use the square footage printed on your specific product's packaging for an accurate count
Cite this page
Your workspace
Most jobs need more than one number. Add the calculators you need next and they open right here, underneath this one — your figures stay on screen and nothing is lost to a page change.
Protection this work requires
- Stop and check first. Textured ceiling coatings, board behind panels, floor tiles and bitumen adhesive in older buildings — built before asbestos was banned or phased out where you are — can contain asbestos, and drilling or sanding them releases fibres. Do not disturb it — have it sampled first. This is not a job for better PPE.
Tools and safety for this job
To fit batt insulation. Generic types, no brands, no prices.
- Mineral and glass wool irritate skin, eyes and airways: cover your arms, wear a P2/N95 respirator while cutting, and rinse in cold water — hot water drives fibres in.
- Most fatal falls on small jobs are from under three metres: use a tower or a ladder tied at the top, and never work off the top two rungs.
- Knives cause more site injuries than any power tool: cut away from your body, change blades often, and wear cut-resistant gloves to EN 388 level C for repeated cutting.
Show the 5 tools this job needsHide tools
Essential
Tape measure
Utility knife
Recommended
Staple gun
Step ladder
Optional
Dust extractor or vacuum with a fine filter
Also needed as materials: replacement blades, staples.
what each insulation tool is for, and the spec that decides which to buy where one does.