  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "insulation-batt-calculator",
  "category": "insulation-efficiency",
  "title": "Insulation Batt Calculator",
  "description": "Estimate how many packages of batt insulation you need to cover an area, using your product's stated coverage.",
  "url": "https://craftquantities.com/calculators/insulation-efficiency/insulation-batt-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/insulation-batt-calculator.json",
  "inputCount": 6,
  "testCaseCount": 3,
  "sourceCount": 1,
  "lastVerified": "2026-10-31",
  "translations": {
    "es-US": "https://craftquantities.com/es/calculators/insulation-efficiency/insulation-batt-calculator/"
  },
  "citation": {
    "author": "Craft Quantities",
    "title": "Insulation Batt Calculator",
    "version": "1.1.0",
    "sourcesChecked": "2026-10-31",
    "url": "https://craftquantities.com/calculators/insulation-efficiency/insulation-batt-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Insulation Batt Calculator. Version 1.1.0. Sources checked 2026-10-31. https://craftquantities.com/calculators/insulation-efficiency/insulation-batt-calculator/",
      "apa": "Craft Quantities. (2026). Insulation Batt Calculator (Version 1.1.0) [Web calculator]. Retrieved from https://craftquantities.com/calculators/insulation-efficiency/insulation-batt-calculator/",
      "harvard": "Craft Quantities (2026) Insulation Batt Calculator (Version 1.1.0). Available at: https://craftquantities.com/calculators/insulation-efficiency/insulation-batt-calculator/",
      "bibtex": "@misc{craftquantities-calculators-insulation-efficiency-insulation-batt-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Insulation Batt Calculator},\n  version      = {1.1.0},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/insulation-efficiency/insulation-batt-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "areaLength",
      "label": "Area Length",
      "type": "number",
      "dimension": "length",
      "defaultValue": 12,
      "min": 0.01,
      "max": 100,
      "step": 0.5,
      "help": "The length of the wall, floor, or attic area to insulate."
    },
    {
      "id": "areaWidth",
      "label": "Area Width",
      "type": "number",
      "dimension": "length",
      "defaultValue": 8,
      "min": 0.01,
      "max": 100,
      "step": 0.5,
      "help": "The width of the area to insulate."
    },
    {
      "id": "coveragePerPackageSqft",
      "label": "Package coverage",
      "type": "number",
      "dimension": "area",
      "defaultValue": 9.290304,
      "min": 0.01,
      "max": 46.45152,
      "step": 0.464515,
      "help": "The square footage one package covers, printed on the product label."
    },
    {
      "id": "wasteFactorPercent",
      "label": "Waste Factor (%)",
      "type": "number",
      "defaultValue": 10,
      "min": 0,
      "max": 20,
      "step": 1,
      "help": "Extra material for cuts around obstructions (pipes, wiring, joists)."
    },
    {
      "id": "layerOneR",
      "label": "First Layer R-Value",
      "type": "number",
      "dimension": "rvalue",
      "defaultValue": 0,
      "min": 0,
      "max": 15,
      "step": 0.01,
      "help": "The rated R-value printed on the first layer's pack; 0 leaves the R rows out."
    },
    {
      "id": "layerTwoR",
      "label": "Second Layer R-Value",
      "type": "number",
      "dimension": "rvalue",
      "defaultValue": 0,
      "min": 0,
      "max": 15,
      "step": 0.01,
      "help": "The rated R-value of a second layer laid over the first, such as a cross layer in a loft; 0 for none."
    }
  ],
  "sources": [
    {
      "label": "Batt/roll insulation coverage per package varies by R-value, thickness, and brand — always use the square footage printed on your specific product's packaging for an accurate count"
    }
  ],
  "testCases": [
    {
      "name": "12x8 ft area, 100 sqft/package, 10% waste",
      "inputs": {
        "areaLength": 3.6576,
        "areaWidth": 2.4384,
        "coveragePerPackageSqft": 9.290304,
        "wasteFactorPercent": 10
      },
      "expected": 2,
      "toleranceDecimalPlaces": 0,
      "unit": "packages",
      "confidence": "high",
      "steps": [
        {
          "label": "Area to insulate",
          "value": 96,
          "unit": "sq ft"
        },
        {
          "label": "Area with waste factor",
          "value": 105.60000000000001,
          "unit": "sq ft"
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    },
    {
      "name": "12x8 ft area, R-13 then R-19 across, 100 sqft/package",
      "inputs": {
        "areaLength": 3.6576,
        "areaWidth": 2.4384,
        "coveragePerPackageSqft": 9.290304,
        "wasteFactorPercent": 10,
        "layerOneR": 2.2895,
        "layerTwoR": 3.3462
      },
      "expected": 2,
      "toleranceDecimalPlaces": 0,
      "unit": "packages",
      "confidence": "high",
      "steps": [
        {
          "label": "Area to insulate",
          "value": 96,
          "unit": "sq ft"
        },
        {
          "label": "Area with waste factor",
          "value": 105.60000000000001,
          "unit": "sq ft"
        },
        {
          "label": "R-value of the layers together, framing ignored",
          "value": 5.6357,
          "unit": "m²K/W"
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    },
    {
      "name": "20x15 ft area, 88.75 sqft/package, 10% waste",
      "inputs": {
        "areaLength": 6.096,
        "areaWidth": 4.572,
        "coveragePerPackageSqft": 8.245145,
        "wasteFactorPercent": 10
      },
      "expected": 4,
      "toleranceDecimalPlaces": 0,
      "unit": "packages",
      "confidence": "high",
      "steps": [
        {
          "label": "Area to insulate",
          "value": 300,
          "unit": "sq ft"
        },
        {
          "label": "Area with waste factor",
          "value": 330,
          "unit": "sq ft"
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    }
  ],
  "usedByAssemblies": [
    {
      "id": "garage-conversion",
      "name": "Garage conversion"
    },
    {
      "id": "attic-insulation",
      "name": "Attic insulation upgrade"
    },
    {
      "id": "framed-exterior-wall",
      "name": "Framed exterior wall"
    }
  ]
}