Hydronic Air/Dirt Separator Sizing Calculator
Calculate the minimum connection size for a hydronic air/dirt separator at the system's design flow rate.
Materials & Quantities
Air and water through a building, and the supports that carry them.

Duct sizing, velocity, friction and equivalent lengths; leakage class and silencer loss; fans, grilles, VAV boxes and reheat coils; filtration and cleanroom airflow; pipe sizing for domestic water, gas and hydronics with Hazen-Williams losses; pumps, expansion tanks and relief valves; condensate, grease traps and trap primers; and the hangers and trapeze supports for all of it.
Whether the fluid is air or water. Both are sized from a flow and a permissible loss, but the loss that governs differs — air is a velocity and a noise limit, water is a head and a velocity limit that protects the pipe from erosion. A calculator that takes a flow without asking which is not answering either question.
The heat loss that sizes the plant, which is an insulation question; the electrical supply feeding the equipment; and the insulation wrapped around the duct.
54 calculators
Calculate the minimum connection size for a hydronic air/dirt separator at the system's design flow rate.
Calculate the number of air jet nozzles needed to cover a cleanroom air shower chamber at a standard spacing.
Calculate the total water weight of a display aquarium, for structural load verification.
Calculate the water velocity through a backflow preventer's pipe connection at a given flow rate.
Calculate the makeup water rate needed to replace system losses in a boiler/hydronic heating system.
Calculate the total dynamic head a hydronic circulator pump must overcome, from friction loss rate and total equivalent pipe length.
Calculate the required supply airflow and HEPA filter face velocity for a cleanroom, based on a target air-changes-per-hour rate by ISO class.
Calculate the minimum free area of combustion air openings for a fuel-burning appliance using the code indoor air method.
Develop the flat pattern for a rolled cone or frustum: the included angle, both radii and the slant height to mark out.
Calculate the recirculation flow rate needed to offset a hot water loop's heat loss and maintain temperature.
Size a domestic water pipe from its fixture unit load against both limits that govern it: the velocity ceiling and the pressure at the furthest fixture.
Calculate the air velocity inside a duct given its airflow and cross-sectional area, with typical recommended velocity ranges by application.
Add the equivalent straight-duct length of a run's elbows and tees to its measured length, for estimating the total system pressure drop.
Calculate the number of hangers needed to support a duct run at its required maximum spacing.
Calculate the maximum allowable duct system leakage rate for a given SMACNA Leakage Class, test pressure, and duct surface area.
Estimate the total sound attenuation from a series of duct silencers or lined duct sections, by summing their rated insertion losses.
Calculate the round duct diameter that delivers equivalent airflow capacity to a given rectangular duct cross-section, using the Huebscher equation.
Calculate the sensible heat energy recovered by an energy/heat recovery ventilator, based on its rated sensible recovery effectiveness.
Estimate friction pressure loss through a flexible duct run from a curve-fit of the ASHRAE duct friction chart, times an installation-quality factor.
Check the galvanic corrosion risk between two dissimilar pipe metals and whether a dielectric union is recommended.
Calculate a fuel gas pipe's volumetric flow capacity at a maximum allowable gas velocity.
Calculate the required grease trap capacity for a commercial kitchen, based on flow rate, retention time, and storage factor.
Calculate the friction head loss in a domestic water supply pipe run using the Hazen-Williams formula.
Estimate a HEPA filter bank's current pressure drop between its rated clean and final (loaded) values, based on a loading percentage.
How much liquid a horizontal cylindrical tank holds at a dipstick depth, with flat, dished or hemispherical ends, and the ullage left above it.
Calculate the moisture addition rate a humidifier must supply to raise an airstream's humidity by a target amount.
Calculate the minimum required drop for an HVAC condensate drain line run, at the standard minimum slope of 1/8 in per foot (10 mm per metre).
Calculate the footprint area needed for an equipment pad or roof curb, including the manufacturer's required service clearance.
Calculate the minimum total (nominal) tank volume for a closed-loop hydronic heating/cooling system's expansion tank.
Calculate the minimum exhaust airflow for an unlisted Type I commercial kitchen hood, per International Mechanical Code duty-rate tables.
Calculate the nitrogen purge gas volume needed to clear a medical gas copper pipeline before commissioning.
A mini-split or VRF system's derated capacity for line set length beyond the base allowance and for vertical rise, at the rates in the maker's manual.
Calculate the resulting mixed-air temperature when outdoor air and return air combine in an air handling unit.
Calculate the required leg length of a pipe expansion loop to absorb thermal movement, sized from your pipe material's own stiffness and allowable stress.
Calculate the total equivalent straight-pipe length contributed by elbows and tees in a piping run.
Calculate the number of hangers needed to support a pipe run at code-required spacing.
Calculate the flow coefficient (Cv) needed to select a pressure reducing valve for a given flow rate and pressure drop.
Calculate the sheet metal surface area needed to fabricate a straight run of rectangular duct, with a waste allowance.
How much refrigerant to weigh in beyond the factory charge when the liquid line runs past the length the unit ships charged for, at the maker's rate.
Turn a refrigerant route's measured run, bends, traps, valves and drier into the equivalent length a heat pump's published maximum is set against.
Look up the typical suction and liquid line copper tubing size for a residential split-system by cooling capacity.
Calculate the discharge flow rate from a reduced-pressure backflow preventer's relief valve, for air gap/drain sizing.
Calculate the gross grille size needed to deliver a target airflow at a target face velocity, accounting for the grille's free-area percentage.
Contents of a spherical or vertical capsule tank at a measured depth, and why a dipstick only tells the truth through the straight middle.
Calculate the slope percentage of a storm drain pipe run from its upstream and downstream invert elevations.
Calculate the minimum discharge pipe diameter needed for a sump pump's flow rate at a safe maximum velocity.
Capacity and contents of a cylinder, rectangular, oval or cone-bottom tank, full or at a measured depth, in litres, cubic metres, US and imperial gallons.
Calculate the total water flow needed for a trap primer system serving multiple floor drain traps.
Develop the flat pattern for a rectangular tapered transition: the true corner edge, both face heights and the blank to cut.
Calculate the sensible heating capacity a VAV terminal's reheat coil must provide for a given airflow and target temperature rise.
Calculate a spring vibration isolator's static deflection under equipment load.
Calculate the pressure surge from a sudden valve closure in a hydronic piping system, using the Joukowsky equation.
Estimate peak water demand from total water supply fixture units, using a Hunter's curve style approximation, to help select a water meter size.
Calculate how far a zone's measured airflow deviates from its design airflow, for testing, adjusting, and balancing (TAB) work.