SettingsSettings for this calculationUS
The pipe invert (bottom interior) elevation at the upstream end of the run.
Take this from your survey or grading plan — the invert is the lowest point of the pipe's interior cross-section, not the top of pipe or the rim elevation.
The pipe invert elevation at the downstream end of the run.
This should be lower than the upstream invert for a gravity-flow drainage pipe.
The horizontal (plan-view) distance between the upstream and downstream structures.
Measure the horizontal run length, not the sloped pipe length — for typical drainage slopes the difference is negligible, but use the plan distance between structures.
Pipe slope
2.33 %
Minimum slope requirements depend on pipe size and expected flow (to maintain self-cleaning velocity) per your local drainage design standard — confirm the calculated slope meets your pipe size's minimum requirement.
They open the calculator with your figures already in it
Storm Drain Pipe Slope Calculator: 2.33 % — shown in imperial, US market. The link sets both, so the result they see is the one on your screen.
Show calculation logicHide calculation logic
How this was calculated
Formula source(s)
- Slope percentage = ((upstream invert elevation − downstream invert elevation) ÷ horizontal distance) × 100, the standard method for checking a gravity drainage pipe's slope against minimum/maximum design requirements
Inputs used
- Upstream Invert Elevation
- 15 ft
- Downstream Invert Elevation
- 11.5 ft
- Horizontal Pipe Run Distance
- 150 ft
Confidence note: Minimum slope requirements depend on pipe size and expected flow (to maintain self-cleaning velocity) per your local drainage design standard — confirm the calculated slope meets your pipe size's minimum requirement.
What this calculation does not cover
- A slope that works hydraulically still has to fit in the ground. The upstream end needs enough cover over the crown for the pipe class and the traffic above it, and the downstream end has to arrive at an invert the outfall, manhole or existing sewer can actually accept — so on a long run the grade is normally dictated by whichever of those two ends is fixed. A percentage chosen freely can bury the outlet below its receiving structure or leave the head of the run too shallow to drive over.
- Inverts are taken as a pair with nothing between them. Chain several runs together and every structure adds a drop of its own: manholes are commonly benched with the outgoing invert 30 to 60 mm (2.4 in) below the incoming one to cover head loss through the chamber, and more where the pipe changes direction or size. Carry a downstream invert straight into the next run as its upstream figure and that fall quietly disappears across the system.
- This is design slope on paper, and what gets accepted is the as-built line. A flexible pipe laid on poorly compacted bedding, or across a soft spot, settles between structures into a belly that ponds water no matter what the two end elevations say — which is exactly what a CCTV survey is looking for. Bedding, haunching and trench compaction are invisible to this arithmetic.
Computed in your browser — nothing you enter is uploaded. Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.
Sources checked 2026-09-06 · in the site-wide review of 2026-09-06 · v1.0.1
Regulatory standards & verification citations1
- Slope percentage = ((upstream invert elevation − downstream invert elevation) ÷ horizontal distance) × 100, the standard method for checking a gravity drainage pipe's slope against minimum/maximum design requirements
Cite this page
Your workspace
Most jobs need more than one number. Add the calculators you need next and they open right here, underneath this one — your figures stay on screen and nothing is lost to a page change.
Tools and safety for this job
To cut and join plastic pipe. Generic types, no brands, no prices.
Protection this work requires
- Knives cause more site injuries than any power tool: cut away from your body, change blades often, and wear cut-resistant gloves to EN 388 level C for repeated cutting.
Cut and join plastic pipe: Push-fit and solvent-weld plumbing is within reach of a competent DIYer. The regulated parts of the system — gas, unvented hot water, and anything notifiable — are not, whatever tools are to hand.
Show the 3 tools this job needsHide tools
Essential
Plastic pipe shears
Tape measure
Recommended
Deburring tool and wire wool
what each plumbing tool is for, and the spec that decides which to buy where one does.