Canvas template

A laundry room drawn and counted: fixtures, drain, appliance outlets, tiles and paint

A working room by the back door: water in, water out, two big appliances and a floor that can get wet.
  • One levelDrawn
  • 32Rows to buy
  • Opens as a new projectIn the canvas

Where the washing happens

Moving the washing machine out of the kitchen is one of the commonest small rebuilds. This laundry is 2.7 by 2.1 m (9 by 7 ft) inside, a size that fits a washer and dryer side by side on the back wall, a deep utility sink beside them and the water heater in the corner by the inside door. The east wall faces the garden and has an outside door, so wet washing goes straight out to the line.

Each piece of equipment is drawn where it stands. The washer's valve box, the sink and the water heater are fixtures; the floor drain is a drain point; the two appliance outlets and one protected outlet by the sink are outlets of their own kinds. The list counts each kind and leaves the pipes and cables between them to the trade who routes them.

Surfaces that cope with water

The floor is tiled, with adhesive and grout from the tile pages, and the walls and ceiling are painted. The outside wall is the House Estimator's framed wall with its door flashed and sealed; the other three are partitions. Skirting, casing round both doors and paint for the woodwork come from the room itself, so stretching the room lengthens all three.

Changing the floor or venting the dryer

A click floor is the first change: tiles, adhesive and grout leave the list and the planks and underlay arrive. The second draws a vented dryer's round duct, 100 mm (4 in) across, from beside the washer along the back wall and out through the outside wall; the duct is listed as sheet metal with its mastic and hangers, and its sections and elbow are counted, while the hood on the outside wall is bought with the dryer.

A new project with this drawing, in your units; nothing you already have is changed, and nothing is uploaded.

How it is drawn

  1. Draw the room by its inside faces. Partitions round 2.7 × 2.1 m (9 × 7 ft); the east wall made the framed outside wall.
  2. Add both doors. An outside door in the east wall and an inside door in the west wall, each 0.6 m (2 ft) from its corner.
  3. Place the equipment. The washer and the sink along the back wall, the water heater by the inside door, a drain in the floor.
  4. Add the outlets. Two dedicated appliance outlets and one protected outlet beside the sink.
  5. Finish the room. Name it Laundry: a tiled floor and painted walls and ceiling.

What a professional decides

The size of the water heater, the drain and vent arrangement for the washer and sink, the circuits for the appliances and whether a gas dryer or heater needs its own flue are a plumber's, an electrician's and, for gas, a registered fitter's decisions. A floor drain may need a trap primer or a non-return valve; your building office says which.

Plan of the laundry room with a back door template, ground floor, to scale, with imperial lengths.
Ground floor, to scale. The canvas's own SVG export of this drawing.
Plan of the laundry room with a back door template, ground floor, to scale, with metric lengths.
Ground floor, to scale. The canvas's own SVG export of this drawing.

Everything to buy

Quantities to order, with each calculator’s own waste. Your own rates go on the lines in My Project.

Walls
Material, and whereQuantity
Framing StudIW-1, Ground floor, 3 walls33 studs
Outlet SpacingIW-1, Ground floor, 3 walls3 outlets (minimum)
Drywall Joint CompoundIW-1, Ground floor, 3 walls1 x 4.5 gal box
Studs, 2×4 (38 × 89 mm) at 16 in (400 mm) centresEW-1, Ground floor13 studs
Plates, headers, sills, cripples, corner and junction studsEW-1, Ground floor30.04 ft
Fibreglass batts, 3 1/2 in (89 mm), for 2×4 cavitiesEW-1, Ground floor1 package
Wall sheathing, OSB 7/16 in (11 mm)EW-1, Ground floor2 sheets (4x8 ft)
House WrapEW-1, Ground floor1 roll
Vinyl sidingEW-1, Ground floor0.3851 squares
Doors and windows
Material, and whereQuantity
Flashing tape round the opening, for a timber-framed wallDR-1, Ground floor28.6 ft
Mastic (caulk) round the frame, outside and insideDR-1, Ground floor2 tubes
Interior doors, 762 × 1981 mm (30 × 78 in)counted on the drawing1 each
Outside doors, 914 × 2134 mm (36 × 84 in)counted on the drawing1 each
Rooms: floors, walls and ceilings
Material, and whereQuantity
Tile adhesive for the floorLaundry2 bags
Floor tilesLaundry18 tiles
Grout for the floor tilesLaundry1.85 lb
Primer for the wallsLaundry1.5 gallons
Wall paintLaundry1.1 gal
Primer for the ceilingLaundry0.5 gallons
Ceiling paintLaundry0.3158 gal
Paint for doors, frames and skirtingLaundry0.5875 gal
Skirting boardsLaundry28.76 linear ft
Door casingLaundry35.75 linear ft
Electrical
Material, and whereQuantity
Lights, ceiling lightcounted on the drawing1 each
Outlets, dedicated appliance outletcounted on the drawing2 each
Outlets, socket protected by a GFCI or RCDcounted on the drawing1 each
Switches, switch for one placecounted on the drawing1 each
Plumbing
Material, and whereQuantity
Drains, floor draincounted on the drawing1 each
Fixtures, water heatercounted on the drawing1 each
Fixtures, kitchen sinkcounted on the drawing1 each
Fixtures, washing machine connectioncounted on the drawing1 each
Heating, cooling and ventilation
Material, and whereQuantity
Registers and grilles, extract fancounted on the drawing1 each
Walls
Material, and whereQuantity
Framing StudIW-1, Ground floor, 3 walls31 studs
Outlet SpacingIW-1, Ground floor, 3 walls3 outlets (minimum)
Drywall Joint CompoundIW-1, Ground floor, 3 walls23.24 kg
Studs, 2×4 (38 × 89 mm) at 16 in (400 mm) centresEW-1, Ground floor13 studs
Plates, headers, sills, cripples, corner and junction studsEW-1, Ground floor9.13 m
Fibreglass batts, 3 1/2 in (89 mm), for 2×4 cavitiesEW-1, Ground floor1 package
Wall sheathing, OSB 7/16 in (11 mm)EW-1, Ground floor2 sheets (2440x1220 mm)
House WrapEW-1, Ground floor1 roll
Vinyl sidingEW-1, Ground floor3.51 m²
Doors and windows
Material, and whereQuantity
Flashing tape round the opening, for a timber-framed wallDR-1, Ground floor8.62 m
Mastic (caulk) round the frame, outside and insideDR-1, Ground floor2 tubes
Interior doors, 800 × 2000 mm (31 1/2 × 78 3/4 in)counted on the drawing1 each
Outside doors, 920 × 2100 mm (36 1/4 × 82 3/4 in)counted on the drawing1 each
Rooms: floors, walls and ceilings
Material, and whereQuantity
Tile adhesive for the floorLaundry2 bags
Floor tilesLaundry18 tiles
Grout for the floor tilesLaundry0.7944 kg
Primer for the wallsLaundry5.68 L
Wall paintLaundry3.99 L
Primer for the ceilingLaundry1.89 L
Ceiling paintLaundry1.14 L
Paint for doors, frames and skirtingLaundry2.2 L
Skirting boardsLaundry8.6 m
Door casingLaundry10.91 m
Electrical
Material, and whereQuantity
Lights, ceiling lightcounted on the drawing1 each
Outlets, dedicated appliance outletcounted on the drawing2 each
Outlets, socket protected by a GFCI or RCDcounted on the drawing1 each
Switches, switch for one placecounted on the drawing1 each
Plumbing
Material, and whereQuantity
Drains, floor draincounted on the drawing1 each
Fixtures, water heatercounted on the drawing1 each
Fixtures, kitchen sinkcounted on the drawing1 each
Fixtures, washing machine connectioncounted on the drawing1 each
Heating, cooling and ventilation
Material, and whereQuantity
Registers and grilles, extract fancounted on the drawing1 each

What changes if

With a click floor instead of tiles

  • Tile adhesive for the floor: 2 bags → none
  • Floor tiles: 18 tiles → none
  • Grout for the floor tiles: 1.85 lb → none
  • Underlay for the click floor: none → 1 roll
  • Click floor: none → 3 packs

With a vented dryer with its duct to the outside wall

  • Round duct, sheet metal: none → 6.56 sq ft
  • Duct mastic: none → 1 quart
  • Duct hangers: none → 2 hangers
  • Duct elbows, 102 mm (4 in) round: none → 1
  • Duct sections, 102 mm (4 in) round, 1500 mm (59 in) long: none → 2

With a click floor instead of tiles

  • Tile adhesive for the floor: 2 bags → none
  • Floor tiles: 18 tiles → none
  • Grout for the floor tiles: 0.7944 kg → none
  • Underlay for the click floor: none → 1 roll
  • Click floor: none → 3 packs

With a vented dryer with its duct to the outside wall

  • Round duct, sheet metal: none → 0.5875 m²
  • Duct mastic: none → 1 quart
  • Duct hangers: none → 2 hangers
  • Duct elbows, 100 mm (4 in) round: none → 1
  • Duct sections, 100 mm (4 in) round, 1500 mm (59 in) long: none → 2

The calculators behind this list

This page counts materials and does not check strength. The same drawing opens in the Construction Canvas, where every figure can be changed; a house drawn from a form is on the House Estimator. For assistants and scripts: the drawing as JSON, in both unit systems, with a link that opens each.