Canvas template

An 11 × 8 m masonry bungalow drawn and counted: block walls, footing, slab and a tile roof

A house built the way much of Europe, Australia and the warmer states build: blocks below, tiles above.
  • One levelDrawn
  • 25Rows to buy
  • Opens as a new projectIn the canvas

Blocks instead of studs

This is the House Estimator's drawing in its masonry family: an 11 by 8 m (36 by 26 ft) footprint of block walls, three partitions across the plan, seven windows and two outside doors on one storey. The outside wall is the masonry build-up the estimator offers, set to concrete blocks, so the list counts blocks and the grout that fills their cores, the bond beam blocks round the top with their steel, the control joints and the weep holes, instead of studs and sheathing.

Block sizes differ between markets, and the masonry type carries both, so each reader's blocks are counted in the size sold where they build, over the same wall face after the openings are taken out. Switch the type to brick and the brick, anchor and movement joint rows take over.

A tile roof at 8 in 12

Concrete tiles need a steeper roof than shingles to shed water across their laps, so the roof is pitched at 8 in 12 with its ridge along the longer side. The tile roof family lists the tiles, the battens they hang on and the ridge tiles from the roof tile page, and the trusses at their spacing. Changing the tile in the roof's type to another profile or to clay changes the count per square metre or square foot.

The footing runs under the outside walls and the slab covers the whole footprint, both at the estimator's opening figures.

Hipped, or lower

Hipping the roof is the first change: four slopes instead of two, a common choice for a bungalow because it keeps the roof low at every wall. The second lowers the pitch to 6 in 12; check that the tile you choose is rated for that pitch before ordering, because many are not.

A new project with this drawing, in your units; nothing you already have is changed, and nothing is uploaded.

How it is drawn

  1. Start from the House Estimator. An 11 × 8 m (36 × 26 ft) footprint, one storey, three partitions and seven windows.
  2. Choose the masonry wall. The block build-up for the outside walls, in your market's block size.
  3. Choose the tile roof. Concrete tiles on trusses, pitched at 8 in 12.
  4. Read the list. Footing, slab, blocks and their grout, bond beams, openings and the roof's tiles and trusses.

What a professional decides

Whether the blocks need reinforcing, how the walls are tied to the roof against uplift, the lintels over each opening and the footing for your ground are decided by an engineer and the local building code; in earthquake or hurricane regions those rules are strict. The tile maker states the lowest pitch and the fixings a tile needs.

Plan of the masonry bungalow, tile roof template, ground floor, to scale, with imperial lengths.
Ground floor, to scale. The canvas's own SVG export of this drawing.
Plan of the masonry bungalow, tile roof template, ground floor, to scale, with metric lengths.
Ground floor, to scale. The canvas's own SVG export of this drawing.

Everything to buy

Quantities to order, with each calculator’s own waste. Your own rates go on the lines in My Project.

Foundation and floor
Material, and whereQuantity
Continuous Footing / Grade Beam VolumeFT-1, Ground floor9.24 yd³
Trench Excavation & Backfill VolumeFT-1, Ground floor14.05 yd³
RebarFT-1, Ground floor24 x 20 ft sticks
ConcreteSL-1, Ground floor12.76 yd³
RebarSL-1, Ground floor75 x 20 ft sticks
Concrete FormworkSL-1, Ground floor18 x 8 ft boards
Walls
Material, and whereQuantity
Cavity Wall Weep Hole SpacingEW-1, Ground floor, 4 walls64 weep holes
Concrete CMU Block Counter & Grout InfillEW-1, Ground floor, 4 walls774 blocks
CMU Bond Beam Block CountEW-1, Ground floor, 4 walls184 bond beam blocks
Masonry Bond Beam RebarEW-1, Ground floor, 4 walls186.47 lb
Masonry Control Joint SpacingEW-1, Ground floor, 4 walls6 control joints
Framing StudIW-1, Ground floor, 3 walls88 studs
Outlet SpacingIW-1, Ground floor, 3 walls9 outlets (minimum)
Drywall Joint CompoundIW-1, Ground floor, 3 walls3 x 4.5 gal boxes
Doors and windows
Material, and whereQuantity
Flashing tape round the opening, for a timber-framed wallDR-1, Ground floor, 2 openings57.2 ft
Architrave (casing) inside, two legs and a headDR-1, Ground floor, 2 openings37.4 linear ft
Mastic (caulk) round the frame, outside and insideDR-1, Ground floor, 2 openings4 tubes
Paint for the door and frame, both faces: undercoat and glossDR-1, Ground floor, 2 openings0.5269 gal
Window Opening Flashing MembraneWN-1, Ground floor, 7 openings171.95 ft
Door & Window CasingWN-1, Ground floor, 7 openings123.18 linear ft
Interior doors, 800 × 2000 mm (31 1/2 × 78 3/4 in)counted on the drawing4 each
Outside doors, 914 × 2134 mm (36 × 84 in)counted on the drawing2 each
Windows, 1219 × 1219 mm (48 × 48 in)counted on the drawing7 each
Roof
Material, and whereQuantity
Roof tiles or slates, battens and ridge tilesRF-1, Ground floor1,267 tiles
Roof trussesRF-1, Ground floor20 trusses
Foundation and floor
Material, and whereQuantity
Continuous Footing / Grade Beam VolumeFT-1, Ground floor7.03 m³
Trench Excavation & Backfill VolumeFT-1, Ground floor10.27 m³ (loose)
RebarFT-1, Ground floor12 x 12 m sticks
ConcreteSL-1, Ground floor9.68 m³
RebarSL-1, Ground floor39 x 12 m sticks
Concrete FormworkSL-1, Ground floor18 x 2.4 m boards
Walls
Material, and whereQuantity
Cavity Wall Weep Hole SpacingEW-1, Ground floor, 4 walls64 weep holes
Concrete CMU Block Counter & Grout InfillEW-1, Ground floor, 4 walls624 blocks
CMU Bond Beam Block CountEW-1, Ground floor, 4 walls166 bond beam blocks
Masonry Bond Beam RebarEW-1, Ground floor, 4 walls85.05 kg
Masonry Control Joint SpacingEW-1, Ground floor, 4 walls6 control joints
Framing StudIW-1, Ground floor, 3 walls88 studs
Outlet SpacingIW-1, Ground floor, 3 walls9 outlets (minimum)
Drywall Joint CompoundIW-1, Ground floor, 3 walls65.26 kg
Doors and windows
Material, and whereQuantity
Flashing tape round the opening, for a timber-framed wallDR-1, Ground floor, 2 openings17.25 m
Architrave (casing) inside, two legs and a headDR-1, Ground floor, 2 openings11.26 m
Mastic (caulk) round the frame, outside and insideDR-1, Ground floor, 2 openings4 tubes
Paint for the door and frame, both faces: undercoat and glossDR-1, Ground floor, 2 openings1.93 L
Window Opening Flashing MembraneWN-1, Ground floor, 7 openings51.59 m
Door & Window CasingWN-1, Ground floor, 7 openings36.96 m
Interior doors, 800 × 2000 mm (31 1/2 × 78 3/4 in)counted on the drawing4 each
Outside doors, 920 × 2100 mm (36 1/4 × 82 3/4 in)counted on the drawing2 each
Windows, 1200 × 1200 mm (47 1/4 × 47 1/4 in)counted on the drawing7 each
Roof
Material, and whereQuantity
Roof tiles or slates, battens and ridge tilesRF-1, Ground floor1,279 tiles
Roof trussesRF-1, Ground floor20 trusses

What changes if

With a hip roof instead of the gable

  • Roof tiles or slates, battens and ridge tiles: 1,267 tiles → 1,290 tiles

With a lower pitch, 6 in 12

  • Roof tiles or slates, battens and ridge tiles: 1,267 tiles → 1,178 tiles

With a hip roof instead of the gable

  • Roof tiles or slates, battens and ridge tiles: 1,279 tiles → 1,301 tiles

With a lower pitch, 6 in 12

  • Roof tiles or slates, battens and ridge tiles: 1,279 tiles → 1,190 tiles

The calculators behind this list

This page counts materials and does not check strength. The same drawing opens in the Construction Canvas, where every figure can be changed; a house drawn from a form is on the House Estimator. For assistants and scripts: the drawing as JSON, in both unit systems, with a link that opens each.