Points first
The plan is a one-bedroom flat 8 by 6 m (26 by 19 ft 6 in) inside: a kitchen-living room across the west side, a bedroom and a bathroom on the east. Its walls are drawn only so the points have somewhere to sit; they have no build-up and add nothing to the list, because a rewire or a replumb leaves them standing.
Every service is a point of its kind: the main panel by the front door, general outlets round the rooms, a ceiling light in each room with switches by the doors, the kitchen sink and the dishwasher connection, the water heater in the kitchen corner, and the bathroom's WC, basin, bath and extract fan. The list counts each kind, so the electrician's and the plumber's schedules come straight from the plan.
Then the runs
The routes are drawn as lines from point to point the way they would be fixed. Three cable circuits leave the panel: the kitchen's along the outside wall, one round to the bedroom, and the lighting circuit through every ceiling point. The water supply runs from the heater past the kitchen sink to the bathroom, and two short waste runs take the bathroom and the sink to the stack.
For each run the service run page gives the length to buy, with the extra at each end and any rises, and the canvas counts its bends, its supports at the spacing the code sets for that product and the coils or lengths it comes in. NM cable is held at 4 1/2 ft (1.37 m) and PEX at 32 in (0.81 m), which is why the pipe needs more supports per metre than the cable.
Copper, or conduit
The first change runs the supply in copper tube instead of PEX: the length to buy and the bends stay the same, but copper is held at wider spacing, so far fewer supports are counted. The second runs every circuit in EMT conduit with wires pulled through, which a commercial unit or a basement flat often requires; its supports are spaced further apart than cable's.
A new project with this drawing, in your units; nothing you already have is changed, and nothing is uploaded.
How it is drawn
- Trace the walls. The flat's outline, 8 × 6 m (26 × 19 ft 6 in), and its two partitions, with no build-up.
- Place the panel and the points. Panel, outlets, lights, switches and every fixture, each with its kind.
- Draw the cable runs. Three circuits from the panel with the cable route tool, NM cable on supports.
- Draw the pipe runs. PEX supply from the heater to the sink and the bathroom; plastic waste to the stack.
- Read the counts. Points by kind, lengths to buy, bends, supports and coils or lengths for each route type.
What a professional decides
How many circuits the flat needs, the cable and breaker sizes, the pipe sizes and the waste falls and vents are an electrician's and a plumber's design under the electrical and plumbing codes, and most places require a licensed installer and an inspection. In a block of flats, the risers, the stack and anything that passes through a fire separation belong to the building's owner or management.