Canvas template

An 8 × 6 m cabin of structural insulated panels drawn and counted: panels, footing, slab and a steep roof

Walls that arrive as insulated panels and go up in days: a cabin for the woods or the back of a plot.
  • One levelDrawn
  • 28Rows to buy
  • Opens as a new projectIn the canvas

Panels, not studs

A structural insulated panel is a sandwich of foam between two boards, made in a factory to the wall's height and joined on site with splines. This cabin is the House Estimator's drawing in its SIP family, 8 by 6 m (26 by 19 ft 6 in) outside, one storey with a partition across the plan, five windows and one door. The list counts the panels over the wall area with the splines that join them and the plates that cap them, a house wrap and siding outside, and plasterboard lining the inside face.

Because the insulation is in the panel, there are no batts and no separate sheathing in the list; that is the main difference from the framed walls of the other houses here, and the reason a panel wall goes up so quickly.

A roof for snow

Cabins are often built where winters are long, so the roof is steep, 10 in 12, and the ice-dam membrane is laid along both eaves. Shingles, underlayment, ridge cap, ridge vent and trusses come from the roof pages as for any gable; the steeper pitch means more roof surface over the same footprint than a 6 in 12 roof would have.

The footing and the slab are the estimator's opening figures, under the walls and over the whole footprint.

Tiles, or more room

The first change puts a tile roof on instead, which swaps the shingle rows for tiles and battens and drops the ice-dam row. The second draws a larger cabin, 9.6 by 7.2 m (31 by 24 ft), the same layout stretched, so every panel, the footing, the slab and the roof grow while the openings stay the same.

A new project with this drawing, in your units; nothing you already have is changed, and nothing is uploaded.

How it is drawn

  1. Start from the House Estimator. An 8 × 6 m (26 × 19 ft 6 in) footprint, one storey, one partition and five windows.
  2. Choose the SIP wall. The structural insulated panel family for the outside walls.
  3. Set the roof. Shingles on trusses at 10 in 12, with ice-dam membrane at both eaves.
  4. Read the list. Footing, slab, the panels and their joints, the openings and the roof.

What a professional decides

Panel thickness, the spline and fixing schedule, how the roof bears on the panels and how the panels are protected from moisture at the base are set by the panel maker's engineer for your loads and climate, and the snow load the roof must carry is your building code's. A cabin far from services also needs decisions on water, waste and power that this drawing does not make.

Plan of the sip cabin, 8 × 6 m template, ground floor, to scale, with imperial lengths.
Ground floor, to scale. The canvas's own SVG export of this drawing.
Plan of the sip cabin, 8 × 6 m template, ground floor, to scale, with metric lengths.
Ground floor, to scale. The canvas's own SVG export of this drawing.

Everything to buy

Quantities to order, with each calculator’s own waste. Your own rates go on the lines in My Project.

Foundation and floor
Material, and whereQuantity
Continuous Footing / Grade Beam VolumeFT-1, Ground floor6.76 yd³
Trench Excavation & Backfill VolumeFT-1, Ground floor11.16 yd³
RebarFT-1, Ground floor18 x 20 ft sticks
ConcreteSL-1, Ground floor6.91 yd³
RebarSL-1, Ground floor42 x 20 ft sticks
Concrete FormworkSL-1, Ground floor13 x 8 ft boards
Walls
Material, and whereQuantity
SIP wall panels, splines and platesEW-1, Ground floor, 4 walls24 panels
House WrapEW-1, Ground floor, 4 walls1 roll
Vinyl sidingEW-1, Ground floor, 4 walls6.9 squares
Drywall or plasterboard lining the inside wall faceEW-1, Ground floor, 4 walls21 sheets (4x8 ft)
Framing StudIW-1, Ground floor27 studs
Outlet SpacingIW-1, Ground floor2 outlets (minimum)
Drywall Joint CompoundIW-1, Ground floor1 x 4.5 gal box
Doors and windows
Material, and whereQuantity
Flashing tape round the opening, for a timber-framed wallDR-1, Ground floor28.6 ft
Architrave (casing) inside, two legs and a headDR-1, Ground floor18.7 linear ft
Mastic (caulk) round the frame, outside and insideDR-1, Ground floor2 tubes
Paint for the door and frame, both faces: undercoat and glossDR-1, Ground floor0.2635 gal
Window Opening Flashing MembraneWN-1, Ground floor, 5 openings122.82 ft
Door & Window CasingWN-1, Ground floor, 5 openings87.99 linear ft
Interior doors, 800 × 2000 mm (31 1/2 × 78 3/4 in)counted on the drawing2 each
Outside doors, 914 × 2134 mm (36 × 84 in)counted on the drawing1 each
Windows, 1219 × 1219 mm (48 × 48 in)counted on the drawing5 each
Roof
Material, and whereQuantity
Roofing ShingleRF-1, Ground floor8.87 squares
Roofing UnderlaymentRF-1, Ground floor1 roll
Roof Eave Ice Dam Protection Membrane Footprint (and Valley Lining)RF-1, Ground floor281.91 sq ft
Roof Ridge CapRF-1, Ground floor1 bundle
Ridge Vent Linear FootageRF-1, Ground floor29.35 ft
Roof trussesRF-1, Ground floor15 trusses
Foundation and floor
Material, and whereQuantity
Continuous Footing / Grade Beam VolumeFT-1, Ground floor5.17 m³
Trench Excavation & Backfill VolumeFT-1, Ground floor8.2 m³ (loose)
RebarFT-1, Ground floor9 x 12 m sticks
ConcreteSL-1, Ground floor5.28 m³
RebarSL-1, Ground floor22 x 12 m sticks
Concrete FormworkSL-1, Ground floor13 x 2.4 m boards
Walls
Material, and whereQuantity
SIP wall panels, splines and platesEW-1, Ground floor, 4 walls24 panels
House WrapEW-1, Ground floor, 4 walls1 roll
Vinyl sidingEW-1, Ground floor, 4 walls65.1 m²
Drywall or plasterboard lining the inside wall faceEW-1, Ground floor, 4 walls22 sheets (2400x1200 mm)
Framing StudIW-1, Ground floor27 studs
Outlet SpacingIW-1, Ground floor2 outlets (minimum)
Drywall Joint CompoundIW-1, Ground floor14.09 kg
Doors and windows
Material, and whereQuantity
Flashing tape round the opening, for a timber-framed wallDR-1, Ground floor8.62 m
Architrave (casing) inside, two legs and a headDR-1, Ground floor5.63 m
Mastic (caulk) round the frame, outside and insideDR-1, Ground floor2 tubes
Paint for the door and frame, both faces: undercoat and glossDR-1, Ground floor0.9641 L
Window Opening Flashing MembraneWN-1, Ground floor, 5 openings36.85 m
Door & Window CasingWN-1, Ground floor, 5 openings26.4 m
Interior doors, 800 × 2000 mm (31 1/2 × 78 3/4 in)counted on the drawing2 each
Outside doors, 920 × 2100 mm (36 1/4 × 82 3/4 in)counted on the drawing1 each
Windows, 1200 × 1200 mm (47 1/4 × 47 1/4 in)counted on the drawing5 each
Roof
Material, and whereQuantity
Roofing ShingleRF-1, Ground floor83.74 m²
Roofing UnderlaymentRF-1, Ground floor1 roll
Roof Eave Ice Dam Protection Membrane Footprint (and Valley Lining)RF-1, Ground floor26.3 m²
Roof Ridge CapRF-1, Ground floor1 bundle
Ridge Vent Linear FootageRF-1, Ground floor9.03 m
Roof trussesRF-1, Ground floor15 trusses

What changes if

With a tile roof instead of shingles

  • Roofing Shingle: 8.87 squares → none
  • Roofing Underlayment: 1 roll → none
  • Roof Eave Ice Dam Protection Membrane Footprint (and Valley Lining): 281.91 sq ft → none
  • Roof Ridge Cap: 1 bundle → none
  • Ridge Vent Linear Footage: 29.35 ft → none
  • Roof tiles or slates, battens and ridge tiles: none → 782 tiles

With a larger cabin, 9.6 × 7.2 m (31 × 24 ft)

  • Continuous Footing / Grade Beam Volume: 6.76 yd³ → 8.2 yd³
  • Trench Excavation & Backfill Volume: 11.16 yd³ → 13.55 yd³
  • Rebar: 18 x 20 ft sticks → 21 x 20 ft sticks
  • Concrete: 6.91 yd³ → 10.14 yd³
  • Rebar: 42 x 20 ft sticks → 58 x 20 ft sticks
  • Concrete Formwork: 13 x 8 ft boards → 16 x 8 ft boards
  • SIP wall panels, splines and plates: 24 panels → 28 panels
  • Vinyl siding: 6.9 squares → 8.57 squares
  • Drywall or plasterboard lining the inside wall face: 21 sheets (4x8 ft) → 26 sheets (4x8 ft)
  • Framing Stud: 27 studs → 30 studs
  • Roofing Shingle: 8.87 squares → 12.58 squares
  • Roof Eave Ice Dam Protection Membrane Footprint (and Valley Lining): 281.91 sq ft → 332.33 sq ft
  • Roof Ridge Cap: 1 bundle → 2 bundles
  • Ridge Vent Linear Footage: 29.35 ft → 34.6 ft
  • Roof trusses: 15 trusses → 17 trusses

With a tile roof instead of shingles

  • Roofing Shingle: 83.74 m² → none
  • Roofing Underlayment: 1 roll → none
  • Roof Eave Ice Dam Protection Membrane Footprint (and Valley Lining): 26.3 m² → none
  • Roof Ridge Cap: 1 bundle → none
  • Ridge Vent Linear Footage: 9.03 m → none
  • Roof tiles or slates, battens and ridge tiles: none → 794 tiles

With a larger cabin, 9.6 × 7.2 m (31 × 24 ft)

  • Continuous Footing / Grade Beam Volume: 5.17 m³ → 6.22 m³
  • Trench Excavation & Backfill Volume: 8.2 m³ (loose) → 9.89 m³ (loose)
  • Rebar: 9 x 12 m sticks → 11 x 12 m sticks
  • Concrete: 5.28 m³ → 7.6 m³
  • Rebar: 22 x 12 m sticks → 30 x 12 m sticks
  • Concrete Formwork: 13 x 2.4 m boards → 16 x 2.4 m boards
  • SIP wall panels, splines and plates: 24 panels → 28 panels
  • Vinyl siding: 65.1 m² → 80.13 m²
  • Drywall or plasterboard lining the inside wall face: 22 sheets (2400x1200 mm) → 27 sheets (2400x1200 mm)
  • Framing Stud: 27 studs → 30 studs
  • Drywall Joint Compound: 14.09 kg → 17.97 kg
  • Roofing Shingle: 83.74 m² → 116.84 m²
  • Roof Eave Ice Dam Protection Membrane Footprint (and Valley Lining): 26.3 m² → 31.19 m²
  • Roof Ridge Cap: 1 bundle → 2 bundles
  • Ridge Vent Linear Footage: 9.03 m → 10.71 m
  • Roof trusses: 15 trusses → 17 trusses

The calculators behind this list

This page counts materials and does not check strength. The same drawing opens in the Construction Canvas, where every figure can be changed; a house drawn from a form is on the House Estimator. For assistants and scripts: the drawing as JSON, in both unit systems, with a link that opens each.