Radiant floor loop takeoff

Pipe for the heated area, the insulation under it and the lagging on every circuit's flow and return to the manifold, for a hydronic underfloor zone.

Measurements in
4
Trades out
3
Calculators
3
Going in
3of 3
My Project
Not in it

No figures of yours yet: a takeoff you add to My Project, or a setup you save, fills these boxes in one press.

Dimensions

Give the job once

Every figure on the right follows these, in the units you choose.

Every trade, from those dimensions

then change a dimension, and each line shows what moved.

Every trade's quantity · 3 rows

3 of 3 going in
ItemQuantityOrderWaste / allowance
Radiant Floor PEX Tubing746.2 linear ft of PEX746.2 linear ft of PEXno pack size recorded10%
Foam Board Insulation15 sheets (4x8 ft)15 sheets (4x8 ft)already whole10%
Pipe Insulation22 x 6 ft sections22 x 6 ft sectionsalready whole10%

Every trade's quantity · 3 rows

3 of 3 going in
ItemQuantityOrderWaste / allowance
Radiant Floor PEX Tubing228.48 m of pex228.48 m of pexno pack size recorded10%
Foam Board Insulation16 sheets (2400x1200 mm)16 sheets (2400x1200 mm)already whole10%
Pipe Insulation40 x 1 m sections40 x 1 m sectionsalready whole10%

Estimates, not a quote. Each row gives its base, the allowance on top, the adjusted figure and what to order; change an allowance in its cell, or open the row to see every figure it rests on. A trade's own page carries what it does not cover — open the one you are about to order against.

3 of 3 trades chosenNot pricedNot in project
Kept on this deviceUnitsImperialMetricMy Projectnot in it yetQuantities only · your own rates · not a structural check

About this job

A takeoff is the trade word for the shopping list a job produces — every material, and how much of each, worked out by its own cited calculator.

This is the heating system rather than the floor over it. Where the bathroom takeoff is about tile on a warm floor, this one is about what makes the floor warm: the length of pipe at a spacing, the insulation that decides which direction the heat goes, and the lagging on the pipes between the zone and the manifold. Every circuit runs its own flow and its own return to the manifold, so those leaders are the route twice for each circuit — circuits × 2 × the route. The pipe row adds that length to the tubing as it stands, on top of the pipe in the heated area, and the lagging row is sized on exactly the same length.

The insulation row is the one that decides whether the system works. A heated screed sitting on an uninsulated slab heats the slab, the hardcore and the ground below it, and the room gets whatever is left. Under-loop insulation is not an efficiency upgrade — it is the difference between a radiant floor and an expensive way to warm the earth.

Spacing is a heat-output decision, not a pipe-saving one. Tighter spacing puts more pipe in the same area and delivers more watts per square metre at a lower water temperature, which is exactly what a heat pump wants. Wider spacing suits a boiler and a well-insulated room, and produces a floor with visible warm and cool stripes if taken too far.

How each line reads

Base
What the calculator gives for these dimensions, before anything is added.
Allowance
Cutting waste, a lap or spare stock — named, with where it comes from, and changeable on the row.
Adjusted
The base with its allowance on top.
Order
What to buy: the adjusted figure in whole boards, bags, rolls or lengths.

The order this happens in

Quantities do not tell you the sequence, and on this job the sequence is where the money goes wrong.

  1. Confirm the floor build-up and the finished level before anything is ordered — the depth is the constraint.
  2. Insulate the full area, edges included, with a perimeter strip up the wall.
  3. Set out the loop so no circuit exceeds the length its pipe diameter allows.
  4. Fix the pipe at the spacing, keeping the flow along the coldest edge.
  5. Pressure-test, and leave it under pressure while the screed is laid.
  6. Commission slowly: bring the screed up to temperature over days, not hours.

What this takeoff does not cover

  • The manifold, actuators, mixing valve, pump and controls.
  • The heat source and whether it can supply this zone at the flow temperature the spacing implies.
  • Screed, its depth and its drying time — which is usually the longest item on the programme.
  • The loop layout. The pipe row is the zone's total, not its split into circuits of a maximum length each or the ports they take; the circuits count here only sizes the leaders.
  • The floor finish over it, and whether that finish tolerates the surface temperature.

Labour by trade

Person-hours from trade rules of thumb at each opening size, one crew per trade working in turn: a planning aid, never a price. The Labour tab follows your own figures.

Metric opening

Zone length 8 m · Zone width 5 m · Manifold to zone, one way 6 m and 1 more of the page's opening figures

TradeCrewPerson-hoursWorking days
Labourer1 labourer9.7 h (5.1–25)1 day
Rated rows9.7 h (5.1–25)1 day

Imperial opening

Zone length 26 ft · Zone width 16.5 ft · Manifold to zone, one way 19.5 ft and 1 more of the page's opening figures

TradeCrewPerson-hoursWorking days
Labourer1 labourer9.7 h (5.1–25)1 day
Rated rows9.7 h (5.1–25)1 day

Quote check

Been given a quote for this job?

Paste it into the radiant floor heating quote check. Every line of it is read against these same calculators and your measurements. Quantities only, never prices.

  • What it leaves out

    Every line this takeoff has that nothing on the quote reads as.

  • What it adds

    Labour, removal, hire, fees — each named for what it is.

  • What to ask

    One list of questions, ready to copy. Never a verdict.

More takeoffs

Other job takeoffs

All job takeoffs

Frequently asked questions

What does the radiant floor heating takeoff give for a typical job?
Opened at Zone length 8 m · Zone width 5 m · Manifold to zone, one way 6 m · Circuits off the manifold 3, it orders: Radiant Floor PEX Tubing, 228 m of pex; Foam Board Insulation, 16 sheets (2400x1200 mm); Pipe Insulation, 40 x 1 m sections. Opened at Zone length 26 ft · Zone width 16.5 ft · Manifold to zone, one way 19.5 ft · Circuits off the manifold 3: Radiant Floor PEX Tubing, 746 linear ft of PEX; Foam Board Insulation, 15 sheets (4x8 ft); Pipe Insulation, 22 x 6 ft sections. Every figure follows the dimensions you give it.
Which calculators does the radiant floor heating takeoff run?
3 calculators, one to a line: Radiant Floor PEX Tubing Calculator, Foam Board Insulation Calculator, Pipe Insulation Calculator. Each has a page of its own with its formula and its sources; the takeoff runs them all on one set of dimensions.
What does the radiant floor heating takeoff leave out?
5 things, each named on this page: The manifold, actuators, mixing valve, pump and controls; The heat source and whether it can supply this zone at the flow temperature the spacing implies; Screed, its depth and its drying time; The loop layout; The floor finish over it, and whether that finish tolerates the surface temperature.
Can I check a quote for this job against the takeoff?
Yes. The radiant floor heating quote check reads a quote's lines against these same calculators and your measurements, and reports what it leaves out, what it adds and what to ask. It reads quantities, never prices.