Recessed lighting layout takeoff
Whether the fittings you plan give the room enough light, how many a target level needs and at what spacing, and whether the circuit will carry them.
A takeoff is the trade word for the shopping list a job produces — every material, and how much of each, worked out by its own cited calculator.
- 6Measurements in
- 3Trades out
Give the job once
Every figure on the right follows these, in the units you choose.
Every trade, from those dimensions
then change a dimension, and each line shows what moved.
| Trade | Quantity | |
|---|---|---|
Lighting Illuminance (Lux) CalculatorThe fittings' rated lumens over the floor area — an upper bound before utilisation and maintenance losses, not the level the room keeps.How this figure was reached
Resting on
Change any other figure on the Lighting Illuminance (Lux) Calculator | 321.16 lux | |
Lumen Method Lighting Calculator (Room Index, Luminaire Count and Spacing)How many of these fittings the target level needs by the lumen method, and the grid and pitch the spacing-to-height ratio allows — at the calculator's placeholder ratio and utilisation factor, which are set from the fitting's data sheet on the line in your project.
Why this quantity?
Resting on
| 16 luminaires | |
Lighting Circuit Connected Load CalculatorConnected load against the breaker, at the default watts per fitting.How this figure was reached
Resting on
Change any other figure on the Lighting Circuit Connected Load Calculator | 480 W | |
Lighting Illuminance (Lux) CalculatorThe fittings' rated lumens over the floor area — an upper bound before utilisation and maintenance losses, not the level the room keeps.How this figure was reached | 320 lux | |
Lumen Method Lighting Calculator (Room Index, Luminaire Count and Spacing)How many of these fittings the target level needs by the lumen method, and the grid and pitch the spacing-to-height ratio allows — at the calculator's placeholder ratio and utilisation factor, which are set from the fitting's data sheet on the line in your project.
Why this quantity? | 16 luminaires | |
Lighting Circuit Connected Load CalculatorConnected load against the breaker, at the default watts per fitting.How this figure was reached | 480 W |
Estimates, not a quote. Each row gives its base, the allowance on top, the adjusted figure and what to order; change an allowance on the row, or open its reasoning to see every figure it rests on. A trade's own page carries what it does not cover — open the one you are about to order against.
Labour and programme
Person-hours for the rows going in, from trade rules of thumb: a range for each piece of work, never a price.
No row going in carries a rate yet.
3 rows carry no hours of their own
- Lighting Illuminance (Lux): a size or a check, not a piece of work
- Lumen Method Lighting (Room Index, Luminaire Count and Spacing): no rate for its work here yet
- Lighting Circuit Connected Load: a size or a check, not a piece of work
Labour and programme
Person-hours for the rows going in, from trade rules of thumb: a range for each piece of work, never a price.
No row going in carries a rate yet.
3 rows carry no hours of their own
- Lighting Illuminance (Lux): a size or a check, not a piece of work
- Lumen Method Lighting (Room Index, Luminaire Count and Spacing): no rate for its work here yet
- Lighting Circuit Connected Load: a size or a check, not a piece of work
Setups you have saved
The build-up, the dimensions and any allowance you changed — kept on this device, and reusable on any job. Your prices are not copied in: they stay in your price book, so a setup never holds a stale one.
How far does a budget go?
At your own prices, with this build-up unchanged.
About this job
Downlight layouts are almost always decided by spacing and almost never checked against light level, which is why so many rooms end up either gloomy or lit like a showroom. The illuminance row asks the question the other way round: for the fittings you intend and the room you have, how many of the fittings' rated lumens are there per unit of floor area? Enter the fitting's own output from its data sheet: a bare lamp's lumens are more than the same lamp gives from inside a can. That is an upper bound. It counts every lumen as reaching the floor, before the room's surfaces and ageing take their share, and in an ordinary room about half of it arrives at the working plane. Around 150 lux (14 fc) maintained suits a living room, 300 (28 fc) a kitchen work surface and 500 (46 fc) a desk, so read that row against roughly twice those — and a room maintained at 800 (74 fc) is not a better room, it is an uncomfortable one.
The lumen method row takes those losses off: how many of these fittings the target level needs, and the grid that keeps every pitch within the fitting's spacing-to-height ratio. The row works over a working plane at worktop height, 0.85 m (2 ft 9 in). That ratio and the utilisation factor belong on the fitting's data sheet, and on this page the row always uses the calculator's placeholders — a ratio of 1.25, a utilisation factor of 0.6 and a maintenance factor of 0.8 — so set them on the line once it is in your project. A rule of thumb — ceiling height divided by two, or a grid at 1.2 m (4 ft) — would be a fabricated spacing.
Average illuminance is also an average. It says nothing about where the light lands, and a layout with the right total in the wrong places gives a bright floor and a dark worktop. Use the number as a sanity check on the fitting count, then place them against what the room is for.
How each line reads
- Base
- What the calculator gives for these dimensions, before anything is added.
- Allowance
- Cutting waste, a lap or spare stock — named, with where it comes from, and changeable on the row.
- Adjusted
- The base with its allowance on top.
- Order
- What to buy: the adjusted figure in whole boards, bags, rolls or lengths.
The order this happens in
Quantities do not tell you the sequence, and on this job the sequence is where the money goes wrong.
- Decide what each part of the room is for before deciding where a fitting goes.
- Check the ceiling void: joists, ducts and insulation all decide where a can can actually sit.
- Keep fittings off the wall by roughly half the spacing, or the walls scallop.
- Confirm the fittings are rated for contact with insulation if they will be covered.
- Wire to a switching arrangement that lets part of the room be lit on its own.
- Aim and test at night before the ceiling is made good.
What this takeoff does not cover
- The fitting's photometric data. The count and the grid rest on its spacing-to-height ratio and utilisation factor, which this page leaves at the calculator's placeholders; set them from the data sheet on the line in your project.
- Fire rating, acoustic rating and the covers a rated ceiling needs at every penetration.
- Dimming, driver compatibility and the flicker a mismatched pair produces.
- Where the light actually falls, which an average illuminance cannot describe.
- Cutting, patching and making good the ceiling.
More takeoffs
Other job takeoffs
Electrical rough-in
3 tradesA starting outlet count by the North American spacing rule, the lighting load and the conduit run for first-fixing a single room.
Run this takeoffService panel upgrade
3 tradesCalculated service load by the NEC methods, a simplified floor to read it against, and the main breaker for the service being considered.
Run this takeoffBathroom ventilation
4 tradesExtract airflow for the room, and the hangers, wrap and mastic for the duct that carries it.
Run this takeoff
Frequently asked questions
- What does the recessed lighting takeoff give for a typical job?
- Opened at Room length 5 m · Room width 4 m · Fittings 8 · Lumens per fitting (the fitting's rated output) 800 · Ceiling height 2.4 m · Target light level 300 lx, it orders: Lighting Illuminance (Lux), 320 lux; Lumen Method Lighting (Room Index, Luminaire Count and Spacing), 16 luminaires; Lighting Circuit Connected Load, 480 W. Opened at Room length 16.5 ft · Room width 13 ft · Fittings 8 · Lumens per fitting (the fitting's rated output) 800 · Ceiling height 8 ft · Target light level 28 fc: Lighting Illuminance (Lux), 321 lux; Lumen Method Lighting (Room Index, Luminaire Count and Spacing), 16 luminaires; Lighting Circuit Connected Load, 480 W. Every figure follows the dimensions you give it.
- Which calculators does the recessed lighting takeoff run?
- 3 calculators, one to a line: Lighting Illuminance (Lux) Calculator, Lumen Method Lighting Calculator (Room Index, Luminaire Count and Spacing), Lighting Circuit Connected Load Calculator. Each has a page of its own with its formula and its sources; the takeoff runs them all on one set of dimensions.
- What does the recessed lighting takeoff leave out?
- 5 things, each named on this page: The fitting's photometric data; Fire rating, acoustic rating and the covers a rated ceiling needs at every penetration; Dimming, driver compatibility and the flicker a mismatched pair produces; Where the light actually falls, which an average illuminance cannot describe; Cutting, patching and making good the ceiling.