Blower Door CFM50 Target Calculator

Find the target CFM50 blower door reading needed to hit a specific ACH50 airtightness goal.

  • Answers as you type
  • Every formula cited
  • Calculated in your browser
SettingsSettings for this calculationUS
Market
Imperial · sales tax
The total conditioned (heated/cooled) floor area of the building.

Use the total finished, conditioned square footage.

The average ceiling height across the conditioned space.

8 ft (2.4 m) is standard for most homes.

Your airtightness goal, e.g. from an energy code requirement or certification program.

Many energy codes target 3-5 ACH50 or lower for new construction; Passive House-style standards target well under 1.

Target CFM50

432 CFM50 (target maximum)

High confidence

Your actual blower door test result should come in at or below this target — this is the inverse of the Air Changes Per Hour Calculator, useful for setting a goal before construction or air sealing work rather than evaluating a completed test.

Building volume
8,640 ft³
Then change the inputs to see how far the answer moves.

Show calculation logic

How this was calculated

Formula source(s)

  • Standard blower door formula rearranged: target CFM50 = (target ACH50 x building volume in cubic feet) / 60

Inputs used

Conditioned Floor Area
1080 sq ft
Average Ceiling Height
8 ft
Target ACH50
3

Intermediate steps

Building volume
8,640 ft³
Final result432 CFM50 (target maximum)

Confidence note: Your actual blower door test result should come in at or below this target — this is the inverse of the Air Changes Per Hour Calculator, useful for setting a goal before construction or air sealing work rather than evaluating a completed test.

What this calculation does not cover

  • Building volume here is nothing more than floor area multiplied by average ceiling height. That ignores the thickness of intermediate floor assemblies, flattens stairwells and double-height spaces into an average, and omits any conditioned basement or attic whose area you did not enter. The target moves in direct proportion to the volume, so a volume measured ten per cent differently from the tester's gives a CFM50 limit ten per cent different — agree the volume basis with whoever will run the test before you build to this number.
  • Nothing here defines the tested envelope: whether an attached garage, an unheated basement, a conditioned crawl space or a plant room sits inside or outside it. That single decision changes both the volume in the denominator and the leakage the fan has to move. Two people can test the same building to two different ACH50 figures purely by drawing the boundary in two different places.
  • ACH50 normalises leakage against volume. UK and much European testing, and some North American programmes, instead specify air permeability or leakage per unit of envelope area. This page never asks for envelope area, so a target handed to you in those terms cannot be met by hitting this CFM50 figure.
  • The number assumes a properly conducted test at 50 Pa. It carries no correction for wind, stack effect or baseline pressure, no averaging of a depressurisation result against a pressurisation one, and no allowance for how the building is prepared — which trickle vents, flues, extract fans and drain traps get sealed and which are left as found. Those are the usual reasons two tests of the same building disagree.
  • This is a target airflow, not a ventilation or combustion-air check. A building tightened towards a low ACH50 needs mechanical ventilation sized and commissioned for it, and any open-flued or naturally aspirated appliance inside the envelope needs its own combustion air and spillage assessment. Hitting this figure says nothing about either, and those are the parts that carry a safety consequence.

Add the equipment this sizes

This result is a specification — 432 CFM50 (target maximum) — not a quantity. Put the thing it sizes into your project: how many, what you call it, and your supplier’s price.

32.86 ft10.02 m32.86 ft10.02 mequivalent area1,080 sq ft100.34 m²10 ft5 m

Computed in your browser — nothing you enter is uploaded. Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.

Sources checked 2026-09-02 · in the site-wide review of 2026-09-06 · v1.0.1

Regulatory standards & verification citations1
  1. Standard blower door formula rearranged: target CFM50 = (target ACH50 x building volume in cubic feet) / 60
Cite this page

Your workspace

Most jobs need more than one number. Add the calculators you need next and they open right here, underneath this one — your figures stay on screen and nothing is lost to a page change.

Now that you have the number

These guides cover the work this quantity is for — the first ones run this calculator inside the section that raises the question.

  • A candle finds the gaps; the merchant needs lengths. Surveying an old house opening by opening, then turning the round into rolls, sweeps, film and tubes.

  • Insulating an Atticuses this calculator

    Attic heat loss ranked biggest hole first: air leakage, bare gaps, depth, the hatch, ducts, then the eave perimeter.

  • Encapsulating a crawlspace is dew-point work: every liner, foam board and dehumidifier decision either moves a condensing surface out of trouble or leaves it there.

Called something else where you work? Airtightness — the term in each market, how close the equivalence really is, and the standard that governs it.

Already gone wrong? There is a draught coming from my window

How to calculate blower door CFM50 target in 4 steps

  1. Conditioned Floor AreaThe total conditioned (heated/cooled) floor area of the building.
  2. Average Ceiling HeightThe average ceiling height across the conditioned space.
  3. Target ACH50Your airtightness goal, e.g. from an energy code requirement or certification program.
  4. Target CFM50The tool computes the target CFM50 from those figures and shows the formula, its sources, and a confidence rating alongside it.

Target CFM50 by conditioned floor area

Page defaults, not your figures above.

Conditioned Floor AreaTarget CFM50 (CFM50 (target maximum))
500 sq ft197
1,000 sq ft394
1,500 sq ft591
2,000 sq ft787

Frequently asked questions

When would I use this instead of the Air Changes Per Hour Calculator?
Use this one before construction or an air-sealing project, to know what CFM50 result you're aiming for. Use the Air Changes Per Hour Calculator afterward, once you have an actual blower door test result, to see what ACH50 you achieved.
Is hitting the target guaranteed by good workmanship alone?
No: careful air sealing — caulk, foam, taped sheathing seams, sealed penetrations — is the main driver, but the actual result depends on many construction details. Most builders targeting an aggressive ACH50 use a blower door test mid-construction to catch and fix leaks before drywall closes up the walls.
Does a lower target always cost more to achieve?
Generally yes, especially at the tightest levels (well under 1 ACH50) which require deliberate air-sealing details throughout construction — but many of the basic measures that get a home to a moderate target (3-5 ACH50) are low-cost, common-sense sealing practices.
Preliminary estimate, not certified engineering. This tool produces an indicative quantity calculation for planning purposes only — it is not a certified structural analysis, a guaranteed material takeoff, or a substitute for building department approval. Always verify measurements on-site and have a licensed contractor or structural engineer review any load-bearing, code-sensitive, or safety-critical work before purchasing materials or starting construction. Spotted an arithmetic or standards error? Report it to contact@craftquantities.com with your inputs — a confirmed fix gets a permanent check of its own, so the same mistake cannot come back.