SettingsSettings for this calculationUS
The total below-grade foundation wall area to be waterproofed.
Measure the height times length of each below-grade wall face that will receive the membrane, and sum them.
The coverage area of a single membrane roll, per the manufacturer.
Check the roll's rated coverage area on the product label or technical data sheet — this varies by roll width and length.
Membrane rolls needed
9 rolls
They open the calculator with your figures already in it
Below-Grade Waterproofing Membrane Roll Calculator: 9 rolls — shown in imperial, US market. The link sets both, so the result they see is the one on your screen.
Show calculation logicHide calculation logic
How this was calculated
Formula source(s)
- Roll count = ceil(wall area ÷ roll coverage area), the standard method for estimating rolled sheet membrane material
Inputs used
- Foundation Wall Area
- 860 sq ft
- Roll coverage area
- 100 sq ft
What this calculation does not cover
- Nothing here asks whether the wall will actually accept the membrane. Self-adhered and torch-applied sheets bond only to a sound, dry, clean substrate, and most carry a minimum application temperature. Honeycombing, unfilled tie holes, form release still on the face, or a wall that is too green or too cold all have to be dealt with first — an unbonded sheet is a channel that carries water sideways behind it, which is worse than no sheet at that spot.
- The membrane still has to survive backfill, and what protects it is not in this count. Sheet membrane punctures easily on angular fill and under the machine placing it, so a protection board or drainage composite normally goes on over the same area. Unlike a miscounted roll, a sheet torn during backfill is buried: it cannot be found or repaired without excavating the wall a second time.
Estimated cost — your price
This site holds no price list for this material — local prices vary too much to publish honestly. Enter your supplier's price and the result is costed with it.
Computed in your browser — nothing you enter is uploaded. Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.
Sources checked 2026-09-06 · in the site-wide review of 2026-09-06 · v1.0.1
Regulatory standards & verification citations1
- Roll count = ceil(wall area ÷ roll coverage area), the standard method for estimating rolled sheet membrane material
Cite this page
Your workspace
Most jobs need more than one number. Add the calculators you need next and they open right here, underneath this one — your figures stay on screen and nothing is lost to a page change.
Tools and safety for this job
To tank the walls and a basement's floor (waterproofing). Generic types, no brands, no prices.
Protection this work requires
- Cutting or grinding concrete, masonry, screed, tile or fibre-cement board releases respirable silica: cut wet or extract at the tool, and wear a P2/N95 respirator at minimum — a nuisance dust mask does not filter it.
- A dust mask does nothing about solvent vapour: ventilate through, and use an organic-vapour (A1) cartridge respirator in an enclosed room.
- Wet cement and lime burn skin and eyes painlessly until the damage is done: waterproof gloves to EN 374, safety glasses whenever the mix can splash, and never kneel in wet mix in permeable trousers.
- Saws, grinders and breakers run above 85 dB, where hearing damage accumulates and does not recover: defenders or plugs for every cut, not just the long ones.
- Breakers and grinders cause permanent nerve damage: limit continuous trigger time, keep hands warm, and stop if fingers tingle or blanch.
- Boards, blocks and bagged material cause most lasting back injuries on small sites: two people or a lifter for full sheets, and never a bag on one shoulder up a ladder.
- Knives cause more site injuries than any power tool: cut away from your body, change blades often, and wear cut-resistant gloves to EN 388 level C for repeated cutting.
Tank the walls and a basement's floor (waterproofing): Applying a slurry or a coating to its maker's instructions is within reach of a competent builder. Which grade of dry space the basement needs (in the UK, BS 8102's grades 1 to 3), whether a barrier on its own will do or a drained cavity is needed with it, and how every joint, penetration and junction is detailed are the waterproofing designer's, and the standard asks for a waterproofing specialist in that design; this site flags the grade and never chooses it. A barrier on the inside face holds back water under pressure only where the wall behind it can carry that pressure, a structural question this site never sizes. On a wall that holds back no ground, where a damp specification names this protection, that specification sets which walls and how high, and the basement grade above does not apply.
Show the 6 tools this job needsHide tools
Essential
Brushes
Mixing bucket or tub
Paddle mixer
SDS rotary hammer
Recommended
Plastering trowel and hawk
Optional
Utility knife
Also needed as materials: replacement blades, SDS bits and chisels.
what each waterproofing tool is for, and the spec that decides which to buy where one does.