The total length of termination bar to be fastened.
Measure the total run of termination bar along the membrane edge, wall base tie-in, or other termination detail.
The on-center spacing between fasteners along the bar.
Common single-ply termination bar fastener spacing is 0.3m (12in) on-center; check the membrane manufacturer's fastening schedule for your specific system and wind uplift rating.
Fasteners needed
170 fasteners
They open the calculator with your figures already in it
Roof Membrane Termination Bar Fastener Calculator: 170 fasteners — shown in imperial, US market. The link sets both, so the result they see is the one on your screen.
Show calculation logicHide calculation logic
How this was calculated
Formula source(s)
- Fastener count = ceil(termination bar length ÷ fastener spacing) + 1, the standard fastening layout method for a continuous termination bar securing a membrane edge
Inputs used
- Termination Bar Length
- 165 ft
- Fastener Spacing
- 11.75 in
What this calculation does not cover
- Assumes one continuous run. The +1 end fastener is added once, so a perimeter broken into separate runs by corners, upstands or penetrations needs one extra fastener per additional run — six runs are five fasteners short of this figure.
- The spacing is the figure you entered, not the figure the membrane system requires. Most manufacturers tighten fastener spacing in the corner and perimeter zones, where wind uplift is highest and where a bar pulling away starts the failure.
- Nothing about the fixing itself. The count does not say whether the fastener suits a concrete, timber or metal deck, nor whether it develops the pull-out value the assembly needs.
- No allowance for a re-drill. A hole that misses the deck or lands in a joint costs a fastener and is normal on a real roof.
Estimated cost — your price
This site holds no price list for this material — local prices vary too much to publish honestly. Enter your supplier's price and the result is costed with it.
Part of bigger jobs
This trade is one line of several job takeoffs. Run the whole job and every other trade comes back with it, off the same measurements.
also measures9 other trades
also measures24 other trades
Computed in your browser — nothing you enter is uploaded. Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.
Sources checked 2026-09-02 · 2 test vectors · in the site-wide review of 2026-09-06 · v1.0.1
Regulatory standards & verification citations1
- Fastener count = ceil(termination bar length ÷ fastener spacing) + 1, the standard fastening layout method for a continuous termination bar securing a membrane edge
Cite this page
Your workspace
Most jobs need more than one number. Add the calculators you need next and they open right here, underneath this one — your figures stay on screen and nothing is lost to a page change.
Tools and safety for this job
To form the upstands and kerbs. Generic types, no brands, no prices.
Protection this work requires
- Most fatal falls on small jobs are from under three metres: use a tower or a ladder tied at the top, and never work off the top two rungs.
- Knives cause more site injuries than any power tool: cut away from your body, change blades often, and wear cut-resistant gloves to EN 388 level C for repeated cutting.
Show the 4 tools this job needsHide tools
Essential
Caulking gun
Cordless drill/driver
Tape measure
Utility knife
Also needed as materials: caulk and sealant cartridges, drill and driver bits, replacement blades.
what each roofing tool is for, and the spec that decides which to buy where one does.