Materials & Quantities

Rain-Screen Cladding Furring Strip Calculator

Calculate the number and total length of vertical furring strips needed for a rain-screen cladding ventilation gap.

  • Answers as you type
  • Every formula cited
  • Calculated in your browser
SettingsSettings for this calculationUS
Market
Imperial · sales tax
The total horizontal width of the wall to be furred out.

Measure the full width of the wall run that will receive vertical furring strips behind the rain-screen cladding.

The on-center spacing between vertical furring strips.

Spacing is set by the cladding manufacturer's fastening requirements and the panel's structural span capacity between supports.

The full height each furring strip must run.

Each vertical furring strip typically runs the full height of the wall to maintain a continuous, unobstructed ventilation gap behind the cladding.

Total furring strip length

310 ft

High confidence
Number of furring strips
31
Then change the inputs to see how far the answer moves.

Show calculation logic

How this was calculated

Formula source(s)

  • Furring strip count = ceil(wall width ÷ strip spacing) + 1, running the full wall height, the standard method for creating a continuous ventilated air gap behind rain-screen cladding

Inputs used

Wall Width
39 ft
Furring Strip Spacing
16 in
Wall Height
10 ft

Intermediate steps

Number of furring strips
31
Final result310 ft

What this calculation does not cover

  • Gives the LENGTH of strip to buy and nothing about its thickness, and the thickness is the cavity. The gap behind the cladding has to be deep enough to drain and to move air — commonly 19 mm (3/4 in), less only on proprietary drained systems rated for it — and a strip ripped thin to save money leaves a cavity that holds water against the sheathing instead of shedding it.
  • Strips have to land on the studs behind, not on the spacing you type. Vertical furring over vertical framing only works where the two line up, so a spacing that falls between studs leaves the cladding hanging on sheathing screws, which will not carry its weight. Where continuous exterior insulation sits between strip and sheathing, screw length and the shear carried through that compressible layer become the real fastening design.
  • Assumes vertical strips for horizontal cladding. Boards that run vertically need the furring horizontal, and horizontal furring dams the cavity unless it is notched, gapped, or laid over a first vertical layer — which roughly doubles the strip quantity returned here.

Estimated cost — your price

This site holds no price list for this material — local prices vary too much to publish honestly. Enter your supplier's price and the result is costed with it.

39 ft11.89 m10 ft3.05 m390 sq ft36.23 m²10 ft2 m

Part of bigger jobs

This trade is one line of several job takeoffs. Run the whole job and every other trade comes back with it, off the same measurements.

Computed in your browser — nothing you enter is uploaded. Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.

Sources checked 2026-09-06 · in the site-wide review of 2026-09-06 · v1.0.1

Regulatory standards & verification citations1
  1. Furring strip count = ceil(wall width ÷ strip spacing) + 1, running the full wall height, the standard method for creating a continuous ventilated air gap behind rain-screen cladding
Cite this page

Your workspace

Most jobs need more than one number. Add the calculators you need next and they open right here, underneath this one — your figures stay on screen and nothing is lost to a page change.

Tools and safety for this job

To fix the cladding battens (furring strips) or rails. Generic types, no brands, no prices.

Protection this work requires

  • Cutting or grinding concrete, masonry, screed, tile or fibre-cement board releases respirable silica: cut wet or extract at the tool, and wear a P2/N95 respirator at minimum — a nuisance dust mask does not filter it.
  • Hardwood dust is a recognised carcinogen: extract at the tool and wear a P2/N95 respirator when cutting or sanding indoors.
  • Saws, grinders and breakers run above 85 dB, where hearing damage accumulates and does not recover: defenders or plugs for every cut, not just the long ones.
  • Breakers and grinders cause permanent nerve damage: limit continuous trigger time, keep hands warm, and stop if fingers tingle or blanch.
  • Boards, blocks and bagged material cause most lasting back injuries on small sites: two people or a lifter for full sheets, and never a bag on one shoulder up a ladder.
  • Most fatal falls on small jobs are from under three metres: use a tower or a ladder tied at the top, and never work off the top two rungs.

Fix the cladding battens (furring strips) or rails: Fixing battens is carpentry. Their section and centres, how they are fixed through any insulation into the wall behind, and for panels on rails the bracket and rail layout, come from the cladding maker's system and, where the wind load calls for it, a fixing design; this site never sizes the battens or their fixings. The battens are measured here, by length, and not again with the boards.

Show the 6 tools this job needs

Essential

  • Circular saw

  • Impact driver

  • Spirit level

  • Tape measure

Recommended

  • Chalk line

  • SDS rotary hammer

Also needed as materials: chalk refill, circular saw blades, impact driver bits, SDS bits and chisels.

what each cladding tool is for, and the spec that decides which to buy where one does.

Now that you have the number

These guides cover the work this quantity is for — the first ones run this calculator inside the section that raises the question.

Called something else where you work? Battens, furring and strapping — the term in each market, how close the equivalence really is, and the standard that governs it.

Still deciding? Rain-Screen Cavity Depth vs Ventilation Area — the factors that actually differ, with no invented prices.

The data behind it: Production rates by operation

How to calculate rain-screen cladding furring strip in 4 steps

  1. Wall WidthThe total horizontal width of the wall to be furred out.
  2. Furring Strip SpacingThe on-center spacing between vertical furring strips.
  3. Wall HeightThe full height each furring strip must run.
  4. Total furring strip lengthThe tool computes the total furring strip length from those figures and shows the formula, its sources, and a confidence rating alongside it.

Total furring strip length by wall width

Page defaults, not your figures above.

Wall WidthTotal furring strip length (ft)
20 ft157
30 ft236
40 ft305
50 ft384
60 ft453
70 ft531

Frequently asked questions

Why is the furring strip count ceil(wall width ÷ spacing) + 1?
A run of vertical strips needs one strip at the starting edge plus one more for every additional spacing interval across the width, so the count is the number of whole spacing intervals that fit (rounded up), plus 1 for the first strip.
Why does each furring strip run the full wall height?
Vertical furring strips create the continuous ventilated air gap behind rain-screen cladding, so each strip is cut to the full wall height to keep that drainage and ventilation path unobstructed from top to bottom.
Does this account for furring strips around openings or corners?
No — this calculates the base quantity for a continuous wall run at a uniform spacing. Extra strips around window and door openings, corner returns, and blocking at penetrations should be added separately from your layout.
Preliminary estimate, not certified engineering. This tool produces an indicative quantity calculation for planning purposes only — it is not a certified structural analysis, a guaranteed material takeoff, or a substitute for building department approval. Always verify measurements on-site and have a licensed contractor or structural engineer review any load-bearing, code-sensitive, or safety-critical work before purchasing materials or starting construction. Spotted an arithmetic or standards error? Report it to contact@craftquantities.com with your inputs — a confirmed fix gets a permanent check of its own, so the same mistake cannot come back.