The total length of the brick veneer wall run.
Measure the horizontal run of the wall along the base of the veneer where vents will be placed.
The on-center spacing between drainage cavity vents.
Standard drainage-cavity ventilation spacing practice commonly uses 24 in (0.61 m) on-center to allow airflow behind the veneer for moisture management.
Drainage vents needed
50 vents
They open the calculator with your figures already in it
Brick Veneer Cavity Drainage Vent Spacing Calculator: 50 vents — shown in imperial, US market. The link sets both, so the result they see is the one on your screen.
Show calculation logicHide calculation logic
How this was calculated
Formula source(s)
- Vent count = ceil(wall length ÷ vent spacing) + 1, following standard drainage-cavity ventilation spacing practice (commonly 24 in / 0.61 m o.c.) to allow airflow behind the veneer for moisture management
Inputs used
- Wall Length
- 98 ft
- Vent Spacing
- 2 ft
What this calculation does not cover
- The result is a count of openings, not a ventilated free area. A vent fitted with a grille, a baffle or an insect screen passes only a fraction of the free area of the hole it occupies, so a run can meet this count and still fall short of the free area per unit length of elevation the wall system calls for; that free-area figure comes from the vent manufacturer and the jurisdiction, not from the spacing used here.
- This sizes one horizontal run of openings. Air only moves through the cavity when there is a path at the head as well as the base, so a drying design normally needs a second row at the top of the veneer or under the eaves, and the calculator has to be run again for that row rather than the base count being read as the whole elevation.
- The wall is treated as one uninterrupted straight run. The count does not deduct window and door openings, and it does not add the extra vents needed immediately above each cavity tray, lintel and flashing, where the cavity is closed off and becomes a separate drainage and ventilation zone with its own openings.
- The plus-one term places a vent at each end of the run. Counting elevations separately and adding the results therefore counts the shared position at every corner twice, so one vent should be deducted for each corner where two runs meet end to end.
Estimated cost — your price
This site holds no price list for this material — local prices vary too much to publish honestly. Enter your supplier's price and the result is costed with it.
Computed in your browser — nothing you enter is uploaded. Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.
Sources checked 2026-09-02 · in the site-wide review of 2026-09-06 · v1.0.1
Regulatory standards & verification citations1
- Vent count = ceil(wall length ÷ vent spacing) + 1, following standard drainage-cavity ventilation spacing practice (commonly 24 in / 0.61 m o.c.) to allow airflow behind the veneer for moisture management