Calculator example · Carpentry

A straight timber stair rising 2.8 m (9.19 ft) between the ground floor and the landing of a house

The flight needs stringers cut from a board 4.47 m (14.7 ft) long. The page follows the rise into risers, the risers into a stringer, the pitch into the opening the floor above must have, and the stringer into the timber and fixings to order.
  • 4.47 mThe answer
  • 6Steps shown
  • UK, metric firstWritten for

The job

Modelled, not recorded. Every figure here is the answer the Stair Stringer Calculator (Cuts, Floor Opening, Treads and Risers) gives for these inputs, written down in both unit systems and re-run whenever the site is built. No job was carried out, so there is no measured overrun on this page.

The rise is 2.8 m (9.19 ft) from the finished hall floor to the finished landing, measured plumb with both floor finishes down. The stair runs straight up against one wall, so one side is open and gets balusters and a handrail, and the other is fixed to the wall. It is the stair most houses have, and the one a joiner or a confident owner builds on site from cut stringers rather than buying a made flight.

The going is chosen, not fitted: there is room in the hall for a flight of ordinary proportions, so the reader keeps a going of 26 cm (10.24 in) and lets the riser count come from a target of 18.5 cm (7.28 in). The section on changes shows what happens when the hall is shorter and the flight has to fit a run instead.

Three stringers carry treads 0.9 m (2.95 ft) long, cut from boards 286 mm (11.26 in) deep. Both figures are the reader's: the calculator cuts and counts the board it is given and never says whether that board, its span or its fixings are adequate, which is the stair maker's or an engineer's call.

Open this job in the calculator

Embed this calculator on your own page

Every figure is worked again by the real calculators, in both unit systems; nothing is priced and nothing is saved until you press Use as my project.

The inputs, exactly as entered

Every input the calculator takes for this job, and why it is what it is
InputValueWhy
Floor-to-floor rise2.8 m (9.19 ft)Finished floor to finished floor, plumb, at the foot of the stair.
What sets the goingI choose the goingThe going is entered, so the run follows from it.
Riser to aim for18.5 cm (7.28 in)A comfortable riser that sits inside the English limits; the count is the whole number nearest it.
Going (tread run)26 cm (10.24 in)Front of one riser to the front of the next, on plan.
Top of the flightUpper floor is the last stepThe landing floor is the last step, so the stringer stops one riser below it.
Stair width0.9 m (2.95 ft)The tread's length between the wall and the open side.
Upper floor depth at the opening25 cm (9.84 in)Landing boards, joists and the hall ceiling together, at the edge of the opening.
Headroom to keep2 m (78.74 in)The clear height Approved Document K asks for over the pitch line.
Nosing projection25 mm (0.98 in)How far each tread overhangs the riser below it.
Tread thickness25 mm (0.98 in)The finished tread, which sets how much the first riser on the stringer is cut short.
Stringer board depth286 mm (11.26 in)The board the stringers are cut from, chosen by the reader.
Stringers3Two outer stringers and one in the middle, by the reader's plan.
RisersClosed, with riser boardsA closed stair, each riser boarded.
Open sides needing balustersOne sideOpen on one side, against a wall on the other.
HandrailsOneOne rail on the open side.
Baluster width41 mm (1.61 in)A square spindle of a common size.
Screws where a board crosses a stringer3The reader's fixing pattern where a tread or riser crosses a stringer.
Tread and riser board length3.6 m (11.81 ft)Boards for the treads and risers come in this length.
Allowance10Spares on the counted items and extra rail; none on the stringers.
Code for the readoutUK — Approved Document KAn English house, so the readout uses Approved Document K.

The working, step by step

  1. 1. Risers

    15 risers

    The rise is divided into the whole number of risers nearest the target: 15 risers, each 186.7 mm (7.35 in). It is the same division the stair rise and run page makes, so both pages agree on the count for this rise.

  2. 2. Treads

    14 treads

    With the landing floor as the last step there is one tread fewer than risers: 14 treads, each 260 mm (10.24 in) on plan. Their goings add up to the run, 3.64 m (11.94 ft), from the face of the header back to the first riser, which is the floor space the flight takes in the hall.

  3. 3. Two risers and a going

    633.3 mm (24.93 in)

    The proportion check: twice the rise plus the going comes to 633.3 mm (24.93 in), and the pitch is 35.68 °. Approved Document K asks for the first between its two limits and the pitch under its maximum, and the readout on the page states both against them without calling the stair compliant.

  4. 4. Throat left under each notch

    134.4 mm (5.29 in)

    Each notch is one rise by one going cut out of the board's top edge, and what is left below it, square to the edge, is the throat: 134.4 mm (5.29 in). It is reported so the reader can hold it against the figure their stair maker or timber supplier works to; the page sets no minimum of its own.

  5. 5. First riser as cut on the stringer

    161.7 mm (6.36 in)

    Every tread sits on a notch, so the whole stringer stands a tread's thickness low. The first riser is cut short by that much, to 161.7 mm (6.36 in), and every finished step then measures the same. The foot is a level cut of 265.2 mm (10.44 in) on the hall floor and the head a plumb cut of 165.4 mm (6.51 in) against the header.

  6. 6. Floor opening length for the headroom

    3.16 m (10.36 ft)

    The pitch line falls one rise for every going away from the top nosing, so the edge of the landing floor clears it by the headroom once it is the headroom plus the floor's depth, times the going over the rise, out from that nosing. With the nosing added, the opening is 3.16 m (10.36 ft) long from the header and 0.9 m (2.95 ft) wide.

Length of board each stringer is cut from

4.47 m

14.7 ft

The headline is the length of board each stringer is cut from: 4.47 m, end to end along its edge. It is longer than the slope of the flight because the board runs past the outer corners of the notches to the two end cuts, and it is bought as the next stock length up, 4.8 m (15.75 ft). Where timber is sold by the foot, the same board is cut from that market's own stock length instead.

What to buy

The quantities this job comes to, and what each is for
QuantityFigureWhat it is for
Length of board each stringer is cut from4.47 m (14.7 ft)Each stringer is cut from one board of at least this length, before any spare.
Stock length for each stringer4.8 m (15.75 ft)The shortest merchant's length that holds one stringer.
Boards for the treads4 boardsWhole boards, each giving as many treads as the stair's width fits into its length.
Boards for the risers5 boardsWhole boards for the riser blanks, counted the same way.
Tread screws139 screwsEvery tread at every stringer, times the fixing pattern, with spares.
Riser screws149 screwsThe same for the riser boards.
Balusters31 balustersEnough per tread to keep every gap under the largest allowed, on the open side.
Handrail, with the allowance5.05 m (16.57 ft)The slope line from foot to head with the allowance; newels and returns are extra.

The allowance, and what it does here

The 10 per cent allowance goes on things that are counted and cut one by one: tread and riser blanks, screws and balusters, each rounded up after the allowance, and on the handrail's length. The stringers get none, because each is one board and a spare is a decision about how much a mis-cut would cost on the day. Boards are counted after the allowance, so a spare tread can push the order up a whole board.

The common mistake

Cutting every riser on the stringer to the same height

The figure that catches most first stringers is the first riser. Marked at a full rise like the rest, it leaves the bottom step a tread's thickness taller than every other step, the trip a building inspector looks for first. Cut the first riser short by the tread's thickness, plus any floor finish still to be laid at the foot, before the stringer is offered up.

Change the job, and see what moves

  • The same flight, with the top tread flush with the landing

    Top of the flight: Top tread flush with the upper floor → 4.79 m (15.7 ft)

    Carry a tread level with the landing instead of stopping a riser below it and the stringer is cut from 4.79 m: one notch longer, which can push it into the next stock length. The run grows by a going to 3.9 m and the opening moves out with it to 3.42 m; the riser count does not change.

  • The same flight, fitted into a shorter hall

    What sets the going: Fit the flight into the run I have; Run available: 3.3 m (10.83 ft) → 4.19 m (13.8 ft)

    Fit the same flight into a hall that allows only 3.3 m and the going shrinks to 235.7 mm, the board to 4.19 m and the opening to 2.87 m. The readout then shows whether that going is still inside the limits, which is the question to settle before the first cut.

What to run next

Sources

The method and every constant behind these figures belong to the Stair Stringer Calculator (Cuts, Floor Opening, Treads and Risers), version 1.0.1, last verified 2026-10-31. It rests on:

  • Cut stringer geometry: each notch is one rise by one going; the board left below a notch, square to the board's edge, is its depth less rise × going ÷ √(rise² + going²); the first riser is cut a tread's thickness short so every finished step is equal
  • US: IRC 2024 R311.7.2 — headroom over a stair at least 6 ft 8 in (2032 mm), measured vertically from the sloped plane through the tread nosings
  • UK: Approved Document K (2013), section 1.10 and Diagram 1.2 — 2.0 m of clear headroom over the flight, measured vertically above the pitch line
  • Australia: ABCB Housing Provisions Standard (NCC 2025), clause 10.3.1(1)(f) — a height of not less than 2.0 m measured vertically above the nosing line of stairway treads
  • Canada: National Building Code of Canada 2020, Sentence 9.8.2.2.(3) — 1 950 mm of clear height over a stair serving a single dwelling unit
  • Guard openings: no gap a 100 mm sphere passes (Approved Document K, NBC) and a 4 in sphere in the IRC (R312.1.3), as the baluster page counts them; a handrail follows the slope, √(rise² + run²), as the handrail page measures it
  • Stock lengths: stringer timber is sold from 3.0 to 6.0 m in 0.6 m steps where it is sold by the metre, and from 10 to 20 ft in 2 ft steps where it is sold by the foot

Frequently asked questions

How long are the stringers for a straight stair rising 2.8 m?
On a going of 26 cm at 15 risers, each stringer is cut from a board 4.47 m long, bought as 4.8 m. The board is longer than the slope because it runs past the notches to the level cut at the foot and the plumb cut at the head.
How long must the stairwell opening be?
For 2 m of headroom under a landing floor 25 cm deep, the opening on this flight is 3.16 m from the face of the header. A deeper floor or a shallower pitch makes it longer.
How many treads and riser boards does this flight need?
14 treads treads and 15 risers riser boards are fixed; with the allowance the order is 16 treads tread blanks from 4 boards boards and 17 risers riser blanks from 5 boards boards.