Materials & Quantities

Stair Stringer Calculator (Cuts, Floor Opening, Treads and Risers)

Cut a straight stair's stringer from the rise: notches, throat and end cuts, the floor opening for headroom, and the treads, risers and fixings to buy.

Length of board each stringer is cut from: 14.6 ft for Floor-to-floor rise 9 ft, Riser to aim for 7.25 in and Going 10.25 in, the page's opening figures; on the metric page, 2.8 m, 18.5 cm and 26 cm give 4.47 m. Source: Australia.

  • Answers as you type
  • 7 sources cited
  • Calculated in your browser
SettingsSettings for this calculationUS
Market
Imperial · sales tax
Who is doing the work?

The standard allowance most suppliers and estimating guides assume for ordinary work.

Finished lower floor to finished upper floor, plumb.

Measure at the stair's foot with the floor finishes in place, or add what is still to go down; every riser is this height shared equally.

Tools needed: Tape measure, Spirit level

Enter the going, or let the run you have share itself over the treads.

Either way the riser count comes from the target riser. Fitting to a run then divides that run over the treads, so a short run shows up as a shallow going in the readout.

The rise is divided into the whole number of risers nearest this.

The same division the stair rise and run page makes, so both pages give the same count for the same rise.

Front of one riser to the front of the next, on plan.

The nosing is added on top of this for the tread board's depth.

Whether the stringer carries a tread level with the upper floor.

Flush adds a tread and one going to the run, and the stringer is cut one notch longer; the riser count is the same.

The tread's length, side to side.

Also the floor opening's width; a wider opening for a wall lining is added by hand.

Upper finished floor down to the ceiling underneath, at the opening's edge.

Boards, joists or trimmer and the ceiling lining together. The deeper it is, the longer the opening has to be to keep the headroom.

Clear height over the pitch line, the line through the nosings.

Opens on the largest of the four codes' figures: 6 ft 8 in (2032 mm) in the IRC, 2.0 m (6 ft 6.7 in) in Approved Document K and the NCC, 1950 mm (6 ft 4.8 in) in Canada's code for a house stair. The readout compares yours.

How far each tread's front edge overhangs the riser below.

Added to the going for the tread board's depth, and to the opening, whose edge is measured from the top nosing.

The finished tread that sits on each notch.

The first riser of the stringer is cut this much short, so the first finished step is as tall as the rest.

The depth of the board you are cutting, not a recommendation.

The throat left under each notch follows from it. Whether the board is deep enough for its span is not worked out here.

How many stringers your plan puts under the treads.

Counted, never chosen here: the spacing a tread can span is the tread maker's or the code's figure.

Closed risers are counted as boards; open risers have none.

An open riser's gap has its own limit in most codes, which is not checked here.

Each open side gets balusters on every tread.

The count per tread keeps every gap at or under 100 mm (3.94 in) in metric and 4 in (101.6 mm) in imperial.

Rails up the slope.

Each is the slope line from the foot to the head; returns, newels and extensions past the flight are added by hand.

The face width of one baluster.

With the largest gap allowed, it sets how many balusters each tread takes.

Your fixing pattern at each tread or riser on each stringer.

Multiplied by the crossings. Glue, plugs and the fixings at the header are not counted.

The length the boards come in.

Each board gives as many treads or risers as the stair's width fits into it whole.

Spare treads, risers, screws and balusters, and extra handrail, as a percentage.

Stringers get none: each is one board, and a spare is your call.

The limits the riser, going and headroom are read against.

Limits checked, not compliance: the building official or building control body decides.

Length of board each stringer is cut from

14.6 ft

≈ 14 ft 6 13/16 in

High confidence

WITHIN THE LIMITS CHECKED — US IRC 2024: riser height 7.20 in (183 mm) and tread depth 10.25 in (260 mm) are inside the limits this calculator checks. That is not a compliance determination: headroom, handrails, guards, nosings and width are not checked, and the building control body or inspector decides. On this page, headroom is read on its own: the opening is worked out for 2032 mm (80.0 in) of headroom over the pitch line, at or above the 6 ft 8 in (2032 mm) of IRC 2024 R311.7.2; the headroom as built is measured on site.

Risers
15 risers
Rise of each step
7.2 in · 7 3/16 in
Going of each step
10.25 in · 10 1/4 in
Treads
14 treads
Total run, header to first riser
11.96 ft · 11 ft 11 1/2 in
Pitch
35.09 °
Two risers and a going
24.65 in · 24 5/8 in
First riser as cut on the stringer
6.2 in · 6 3/16 in
Throat left under each notch
5.36 in · 5 3/8 in
Plumb cut at the head
6.55 in · 6 9/16 in
Level cut at the foot
10.75 in · 10 3/4 in
Floor opening length for the headroom
10.73 ft · 10 ft 8 3/4 in
Floor opening width
3 ft
Stringers
3 stringers
Stock length for each stringer
16 ft
Tread blanks with the allowance
16 treads
Tread board depth (going plus nosing)
11.25 in · 11 1/4 in
Boards for the treads
4 boards
Riser blanks with the allowance
17 risers
Boards for the risers
5 boards
Tread screws
139 screws
Riser screws
149 screws
Balusters
31 balusters
Handrail, with the allowance
16.46 ft · 16 ft 5 9/16 in
Then change the inputs to see how far the answer moves.

Show calculation logic

How this was calculated

Formula source(s)

  • Cut stringer geometry: each notch is one rise by one going; the board left below a notch, square to the board's edge, is its depth less rise × going ÷ √(rise² + going²); the first riser is cut a tread's thickness short so every finished step is equal
  • US: IRC 2024 R311.7.2 — headroom over a stair at least 6 ft 8 in (2032 mm), measured vertically from the sloped plane through the tread nosings
  • UK: Approved Document K (2013), section 1.10 and Diagram 1.2 — 2.0 m of clear headroom over the flight, measured vertically above the pitch line
  • Australia: ABCB Housing Provisions Standard (NCC 2025), clause 10.3.1(1)(f) — a height of not less than 2.0 m measured vertically above the nosing line of stairway treads
  • Canada: National Building Code of Canada 2020, Sentence 9.8.2.2.(3) — 1 950 mm of clear height over a stair serving a single dwelling unit
  • Guard openings: no gap a 100 mm sphere passes (Approved Document K, NBC) and a 4 in sphere in the IRC (R312.1.3), as the baluster page counts them; a handrail follows the slope, √(rise² + run²), as the handrail page measures it
  • Stock lengths: stringer timber is sold from 3.0 to 6.0 m in 0.6 m steps where it is sold by the metre, and from 10 to 20 ft in 2 ft steps where it is sold by the foot

Inputs used

Floor-to-floor rise
9 ft
What sets the going
I choose the going
Riser to aim for
7.25 in
Going (tread run)
10.25 in
Run available
12 ft
Top of the flight
Upper floor is the last step
Stair width
3 ft
Upper floor depth at the opening
9.75 in
Headroom to keep
80 in
Nosing projection
1 in
Tread thickness
1 in
Stringer board depth
11.25 in
Stringers
3
Risers
Closed, with riser boards
Open sides needing balusters
One side
Handrails
One
Baluster width
1.5 in
Screws where a board crosses a stringer
3
Tread and riser board length
12 ft
Allowance
10
Code for the readout
US — IRC 2024

Intermediate steps

Risers
15 risers
Rise of each step
7.2 in
Going of each step
10.25 in
Treads
14 treads
Total run, header to first riser
11.96 ft
Pitch
35.09 °
Two risers and a going
24.65 in
First riser as cut on the stringer
6.2 in
Throat left under each notch
5.36 in
Plumb cut at the head
6.55 in
Level cut at the foot
10.75 in
Floor opening length for the headroom
10.73 ft
Floor opening width
3 ft
Stringers
3 stringers
Stock length for each stringer
16 ft
Tread blanks with the allowance
16 treads
Tread board depth (going plus nosing)
11.25 in
Boards for the treads
4 boards
Riser blanks with the allowance
17 risers
Boards for the risers
5 boards
Tread screws
139 screws
Riser screws
149 screws
Balusters
31 balusters
Handrail, with the allowance
16.46 ft
Final result14.57 ft

Confidence note: WITHIN THE LIMITS CHECKED — US IRC 2024: riser height 7.20 in (183 mm) and tread depth 10.25 in (260 mm) are inside the limits this calculator checks. That is not a compliance determination: headroom, handrails, guards, nosings and width are not checked, and the building control body or inspector decides. On this page, headroom is read on its own: the opening is worked out for 2032 mm (80.0 in) of headroom over the pitch line, at or above the 6 ft 8 in (2032 mm) of IRC 2024 R311.7.2; the headroom as built is measured on site.

What this calculation does not cover

  • The stringer's depth and the number of stringers are yours: this cuts and counts the board you name and never says whether it, its span or its fixings are adequate. That is the stair maker's or an engineer's determination.
  • The opening is the length that keeps the headroom you enter over the pitch line, measured from the face of the header; the trimming round the opening, its joists and hangers are not counted or sized.
  • The code readout checks the riser, the going and the headroom figure against the code chosen and says only that they sit inside or outside those limits. Width, handrail and guard heights, landings, open risers and nosing rules are not checked.
  • Treads and risers are counted as blanks cut from boards of the stock length entered, with nothing for the saw kerf; a tread wider than one board is glued up from several and counted by the board's own page.
  • One straight flight between two floors. Landings, winders and spiral stairs are worked on their own pages.

Estimated cost — your price

This site holds no price list for this material — local prices vary too much to publish honestly. Enter your supplier's price and the result is costed with it.

3 ft
Schematic, drawn to the proportions you entered — not to scale on screen.

Computed in your browser — nothing you enter is uploaded. Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.

Sources checked 2026-10-31 · 7 test vectors · v1.0.1

Regulatory standards & verification citations7
  1. Cut stringer geometry: each notch is one rise by one going; the board left below a notch, square to the board's edge, is its depth less rise × going ÷ √(rise² + going²); the first riser is cut a tread's thickness short so every finished step is equal
  2. US: IRC 2024 R311.7.2 — headroom over a stair at least 6 ft 8 in (2032 mm), measured vertically from the sloped plane through the tread nosings
  3. UK: Approved Document K (2013), section 1.10 and Diagram 1.2 — 2.0 m of clear headroom over the flight, measured vertically above the pitch line
  4. Australia: ABCB Housing Provisions Standard (NCC 2025), clause 10.3.1(1)(f) — a height of not less than 2.0 m measured vertically above the nosing line of stairway treads
  5. Canada: National Building Code of Canada 2020, Sentence 9.8.2.2.(3) — 1 950 mm of clear height over a stair serving a single dwelling unit
  6. Guard openings: no gap a 100 mm sphere passes (Approved Document K, NBC) and a 4 in sphere in the IRC (R312.1.3), as the baluster page counts them; a handrail follows the slope, √(rise² + run²), as the handrail page measures it
  7. Stock lengths: stringer timber is sold from 3.0 to 6.0 m in 0.6 m steps where it is sold by the metre, and from 10 to 20 ft in 2 ft steps where it is sold by the foot

Which documents these citations point at

  • International Residential Code — 2024 R311.7.2 (United States)One- and two-family dwellings and townhouses up to three storeys — structure, fire safety, energy, plumbing, mechanical and electrical in a single document.
  • Approved Documents to the Building Regulations (England) — K (United Kingdom)Practical guidance on meeting the Building Regulations, one lettered part per subject — Part A structure, Part B fire, Part K protection from falling, Part L conservation of fuel and power, and the rest.

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments. This site holds no adoption data for any authority, so check what is in force with the authority where you build. Any section cited above without an edition should be checked against the edition in force where you build. What it would take to know.

Cite this page

Your workspace

Most jobs need more than one number. Add the calculators you need next and they open right here, underneath this one — your figures stay on screen and nothing is lost to a page change.

The flight drawn, cut and counted

A scaled elevation and plan of this flight, the floor opening its headroom needs, the stringer’s cuts, and the treads, riser boards, screws, balusters and handrail to buy, with the code readout and a button that draws it in the Construction Canvas.

Full-size stringer template

Print the stringer worked out above at full size, as a one-notch step gauge or the whole board, split over A4 or Letter sheets with a calibration square and a ruler in both units on each, so a print your printer scaled is caught before the first cut.

Now that you have the number

These guides cover the work this quantity is for — the first ones run this calculator inside the section that raises the question.

Worked for one job: A straight house flight, stringer to cut list

Every stair type, the planner and the templates: the Stairs hub

How to calculate stair stringer (cuts, floor opening, treads and risers) in 22 steps

  1. Floor-to-floor riseFinished lower floor to finished upper floor, plumb.
  2. What sets the goingEnter the going, or let the run you have share itself over the treads.
  3. Riser to aim forThe rise is divided into the whole number of risers nearest this.
  4. Going (tread run)Front of one riser to the front of the next, on plan.
  5. Run availableFrom the face of the header at the top to where the first riser may stand.
  6. Top of the flightWhether the stringer carries a tread level with the upper floor.
  7. Stair widthThe tread's length, side to side.
  8. Upper floor depth at the openingUpper finished floor down to the ceiling underneath, at the opening's edge.
  9. Headroom to keepClear height over the pitch line, the line through the nosings.
  10. Nosing projectionHow far each tread's front edge overhangs the riser below.
  11. Tread thicknessThe finished tread that sits on each notch.
  12. Stringer board depthThe depth of the board you are cutting, not a recommendation.
  13. StringersHow many stringers your plan puts under the treads.
  14. RisersClosed risers are counted as boards; open risers have none.
  15. Open sides needing balustersEach open side gets balusters on every tread.
  16. HandrailsRails up the slope.
  17. Baluster widthThe face width of one baluster.
  18. Screws where a board crosses a stringerYour fixing pattern at each tread or riser on each stringer.
  19. Tread and riser board lengthThe length the boards come in.
  20. AllowanceSpare treads, risers, screws and balusters, and extra handrail, as a percentage.
  21. Code for the readoutThe limits the riser, going and headroom are read against.
  22. Length of board each stringer is cut fromThe tool computes the length of board each stringer is cut from from those figures and shows the formula, its sources, and a confidence rating alongside it.

Length of board each stringer is cut from by floor-to-floor rise

Page defaults, not your figures above.

Floor-to-floor riseLength of board each stringer is cut from (ft)
4 ft6.11
6 ft9.34
8 ft12.6
10 ft15.8
12 ft19.8
14 ft23
16 ft26.2

Frequently asked questions

How long a board do I need for a stair stringer?
Longer than the slope of the flight: the board runs from the level cut at the foot to the plumb cut at the head, past the outer corners of the notches. For a 2.80 m (9 ft 2 in) rise at 15 risers and a 260 mm (10.24 in) going it is about 4.47 m (14 ft 8 in), so it is cut from a 4.8 m or 16 ft length.
How big does the opening in the floor above have to be?
Long enough that the edge of the floor clears the pitch line by the headroom. Add the floor's depth to the headroom, multiply by the going over the rise, and add the nosing: the IRC's 6 ft 8 in (2032 mm) under a 250 mm (9.84 in) floor on that flight needs about 3.20 m (10 ft 6 in) of opening from the face of the header, and Approved Document K's 2.0 m (6 ft 6.7 in) about 3.16 m (10 ft 4 in). Its width is the stair's.
What is the throat of a stringer?
The timber left under a notch, measured square to the board's edge. It is the board's depth less the notch depth, and the notch depth is the rise times the going over one step along the edge. The figure is reported so you can hold it against the minimum your stair maker, your timber supplier or your code works to; this page sets none.
Why is the first riser on the stringer shorter than the others?
Because every tread sits on a notch, the whole stringer stands a tread's thickness lower than the finished steps. Cutting that much off the first riser, and no other, makes the first finished step as tall as the rest; a floor finish still to be laid at the foot is added back.
What changes when the top tread is flush with the upper floor?
The stringer carries one more tread, level with the upper floor, so the flight is a going longer on plan and the opening moves out by the same going; the riser count does not change. The board is cut one notch longer, which can push it into the next stock length.
Preliminary estimate, not certified engineering. This tool produces an indicative quantity calculation for planning purposes only — it is not a certified structural analysis, a guaranteed material takeoff, or a substitute for building department approval. Always verify measurements on-site and have a licensed contractor or structural engineer review any load-bearing, code-sensitive, or safety-critical work before purchasing materials or starting construction. Spotted an arithmetic or standards error? Report it to contact@craftquantities.com with your inputs — a confirmed fix gets a permanent check of its own, so the same mistake cannot come back.