The job
Modelled, not recorded. Every figure here is the answer the Stair Rise & Run Calculator gives for these inputs, written down in both unit systems and re-run whenever the site is built. No job was carried out, so there is no measured overrun on this page.
The house is a double-storey build of the kind a volume builder or an owner-builder puts up on a suburban block: a slab on the ground, a timber or steel-framed upper floor, and one straight flight rising from the entry hall to the landing above. The height that matters is finished floor to finished floor, 2.7 m (8.86 ft), taken after the floor coverings are decided, because tiles below and carpet above each shift the first and last step.
The target rise and the going are the starting figures a stair builder in Australia tends to sketch with: 17.5 cm for the rise and 25 cm for the going. Neither is a requirement. They sit comfortably inside the NCC band, and they leave room to move either way once the count is whole, which is the point of starting from a target rather than from a fixed rise.
The page is written for an Australian reader on purpose. The NCC Housing Provisions cap the rise, put a floor and a ceiling on the going, and ask that twice the rise plus the going fall inside a stated range; the calculator returns each of those rows when its code is set to Australia. Whether a particular stair complies is for the certifier or building surveyor on the job, and the state's adoption of the NCC governs; this page counts and compares, and certifies nothing.
Open this job in the calculator
Embed this calculator on your own page
Every figure is worked again by the real calculators, in both unit systems; nothing is priced and nothing is saved until you press Use as my project.
The inputs, exactly as entered
| Input | Value | Why |
|---|---|---|
| Total Rise (floor to floor) | 2.7 m (8.86 ft) | Finished floor to finished floor, measured plumb at the line of the stair once the coverings are known, not from the top of the slab to the top of the joists. |
| Target Riser Height | 17.5 cm (6.89 in) | A starting figure rather than a result: the calculator rounds the count of risers to a whole number and then shares the height equally, so the rise it reports is close to this and rarely equal to it. |
| Planned Tread Depth (Going) | 25 cm (9.84 in) | The going the builder plans to cut, measured horizontally from nosing to nosing; it is kept as entered, and the calculator sets it beside its own comfort figure. |
| Building Code Reference | Australia — NCC Housing Provisions (rise 115–190 mm / going 240–355 mm) | The rule set an Australian reader's page opens on. It changes which limits the result rows show, never the riser count itself. |
| Headroom Over the Flight | 2.03 m (6.67 ft) | Left at the calculator's own default. |
| Upper Floor Depth at the Opening | 30 cm (11.81 in) | Left at the calculator's own default. |
The working, step by step
1. Actual riser height
180 mm (7.09 in)
The height is divided by the target to find how many rises it holds, the answer is rounded to a whole number of steps, and the height is then shared out equally: 180 mm (7.09 in) per riser. Every step in a flight has to be the same, so this shared figure is what the stringers are set out to, not the target typed in.
2. Number of treads (steps)
14 treads
A straight flight has one tread fewer than it has risers, because the top riser lands on the upper floor itself: 15 risers give 14 treads. That count, multiplied by the going, is the run of the flight on plan, which is the figure to check against the length of the hall before anything is cut.
3. Recommended tread depth (comfort formula)
275 mm (10.83 in)
The calculator also offers a comfortable going for the rise it settled on, from the long-standing pace formula, 275 mm (10.83 in). It is advice, not a limit. Here it is longer than the planned going, which says the flight as sketched is on the steep side of comfortable while still inside every limit below; a hall with room to spare could take the longer going.
4. Code max riser height (Australian NCC Housing Provisions)
190 mm (7.48 in)
With the code set to Australia the readout lists the NCC's ceiling on the rise, 190 mm (7.48 in), and beside it the floor on the going, 240 mm (9.45 in). The rise of 180 mm sits under the first and the planned going sits over the second, so both single-figure checks pass with something in hand.
5. Twice the rise plus the going (NCC Table 11.2.2a)
610 mm (24.02 in)
The third row is the one an Australian reader meets that a North American one does not: twice the rise added to the going, 610 mm (24.02 in). The NCC asks for this sum to fall inside a band, because a step that is both tall and deep is as awkward as one that is short and shallow. Read it against the band printed in the provisions the certifier works from.
Number of risers needed
15 risers
The answer is a layout, not an order: 15 risers at 180 mm with 14 treads, on a planned going of 25 cm. Those three numbers are what the stringers are marked from and what a certifier will measure on site. The calculator's confidence is high because the inputs sit in the middle of the ranges it checks; it says nothing about balustrades, landings or the headroom over the flight, which the NCC also governs and which this page does not count.
What to buy
| Quantity | Figure | What it is for |
|---|---|---|
| Number of risers needed | 15 risers | Nothing is bought from a riser count. It sets the stringer layout, the number of treads and risers to cut, and how many balusters the balustrade will need once its spacing is known. |
The allowance, and what it does here
A riser count has no allowance in it: a stair cannot be built with a spare step. The waste on this job lives in the materials the layout calls for, the stringer timber, the treads and the balustrade, and each of those is counted by its own calculator with its own allowance. The one margin worth keeping here is in the height. Measure it twice, after the coverings are chosen, because a floor finish that adds even a little at the bottom or the top makes the first or last step differ from the rest, and that is the step people trip on.
The common mistake
Measuring the height before the floor finishes are chosen
The height is often taken from the top of the slab to the top of the upper floor's sheeting while the house is still a frame. Tiles and their bed at the bottom, and carpet and underlay at the top, are added later, and they do not cancel out. The stringers are then cut to a height that is no longer the height, and the first or last step ends up a different size from the others. A flight whose steps are equal except one is the stair a certifier is most likely to fail, and the one most likely to trip someone. Take the figure from finished floor to finished floor, and rerun the calculator if the finishes change.
Change the job, and see what moves
The same rise, at a taller target riser
Target Riser Height: 19 cm (7.48 in) → 14 risers
Start from a taller target of 19 cm and the calculator settles on 14 risers, each of 192.9 mm. One step fewer saves run on plan, but the shared rise now sits above the NCC ceiling of 190 mm, and twice the rise plus the going grows to 635.7 mm. The target is only a starting point; the rows below the count are what decide whether a target is usable.
The same rise, at a lower target riser
Target Riser Height: 16 cm (6.3 in) → 17 risers
Start lower, at 16 cm, and the flight becomes 17 risers of 158.8 mm, with 16 treads. Every limit still passes and the climb is easier, but two more treads at the same going lengthen the flight on plan; in a narrow hall that run is often what decides between the two.
What to run next
- Stair Stringer Calculator (Cuts, Floor Opening, Treads and Risers)
The riser and going settled here are what the stringer is marked out from, notch by notch, along with the length of board it is cut from.
- Deck Baluster Calculator
A stair this tall needs a balustrade along its open side, and the number of balusters follows from the flight's length and the gap the NCC allows between them.
- Handrail Length Calculator
The handrail runs the length of the flight on the slope, so its length comes from the same rise and run.
Sources
The method and every constant behind these figures belong to the Stair Rise & Run Calculator, version 1.3.0, last verified 2026-10-31. It rests on:
- Comfortable stair proportion rule of thumb: 2 x riser height + tread depth = 24-25 inches; a riser of about 175–190 mm (6.9–7.5 in) is a comfortable target that sits inside all four codes this page checks
- US: IRC 2024 R311.7.5 — maximum riser height 7.75 in, minimum tread depth (going) 10 in
- UK: Approved Document K (2013), Section 1, Table 1.1 — a private stair's rise 150–220 mm and going 220–300 mm, pitch at most 42°, and twice the rise plus the going between 550 and 700 mm
- Australia: ABCB Housing Provisions Standard, Part 11.2, clause 11.2.2 and Table 11.2.2a, called up by NCC Volume Two for houses; the same table in NCC 2022 and NCC 2025. A stairway other than a spiral stair has risers of 115–190 mm, goings of 240–355 mm and a slope relationship 2R + G of 550–700 mm; each flight has not more than 18 and not less than 2 risers (11.2.2(1)(a)); goings and risers are constant through a flight, within 5 mm between neighbours and 10 mm across the flight (11.2.2(1)(c)); and risers have no opening a 125 mm sphere can pass through (11.2.2(1)(d)). Under 11.2.2(2), a stairway serving only non-habitable rooms such as attics and storerooms that are not used on a regular or daily basis may use Table 11.2.2b instead: riser 130–225 mm, going 215–355 mm and 2R + G 540–700 mm. NCC Volume One, clause D3D14 and Table D3D14, gives a public stairway in other buildings a going of 250–355 mm with the same risers and 2R + G
- Canada: National Building Code of Canada 2020, Volume 2, Division B, Section 9.8, for a private stair (one serving a single dwelling unit, a house with a secondary suite, or a garage serving either): rise 125–200 mm (Article 9.8.4.1, Table 9.8.4.1), run 255–355 mm (Article 9.8.4.2, Table 9.8.4.2), each tread's depth between its run and its run plus 25 mm (Sentence 9.8.4.2.(2)), risers and runs uniform within 5 mm between neighbours and 10 mm across a flight (Article 9.8.4.4), no flight more than 3.7 m high (Article 9.8.3.3), and 1 950 mm of clear height over a stair serving a single dwelling unit (Sentence 9.8.2.2.(3)). A public stair has a rise of 125–180 mm and a run of at least 280 mm. Provinces and territories adopt the NBC with amendments of their own, so check the edition in force where you build
This job is one of that calculator’s published test vectors, which the test suite re-runs on every build.
Frequently asked questions
- How many steps does a 2.7 m stair need in Australia?
- At a target rise of 17.5 cm, the calculator divides the height into 15 risers of 180 mm each, with 14 treads between them. Each of those sits inside the NCC limits the calculator reads it against; the certifier on the job decides compliance.
- What is the 2R + G check on an Australian stair?
- Twice the rise plus the going, a test of how a step's two dimensions work together. On this flight it comes to 610 mm; the NCC Housing Provisions give the band it must fall in, and the calculator prints the sum for the reader to compare.
- Why does the calculator suggest a deeper going than the one entered?
- Its comfort figure, 275 mm, comes from the pace formula for the rise it settled on. It is advice for an easier climb, not a limit; the planned 25 cm already clears the NCC floor of 240 mm.