SettingsSettings for this calculationUS
The building's average daily greywater generation.
Base this on the number and type of greywater-generating fixtures (showers, laundry, lavatories) served and their typical daily usage.
The multiplier applied to the daily average to size for short-duration peak demand.
Peaking factor depends on the building's occupancy pattern and fixture usage profile — a household with concentrated morning fixture use needs a higher factor than one with steady usage through the day.
Peak inflow rate
325 gal/day
Peaking factor depends on the building's occupancy pattern and fixture usage profile — confirm the appropriate factor for your specific application against local greywater reuse code requirements.
They open the calculator with your figures already in it
Greywater Collection Cistern Peak Inflow Calculator: 325 gal/day — shown in imperial, US market. The link sets both, so the result they see is the one on your screen.
Show calculation logicHide calculation logic
How this was calculated
Formula source(s)
- Peak inflow rate = average daily flow × peaking factor, the standard method for sizing detention/collection systems to handle short-duration peak demand rather than just the daily average
Inputs used
- Average Daily Greywater Flow
- 130 gal
- Peaking Factor
- 2.5
Confidence note: Peaking factor depends on the building's occupancy pattern and fixture usage profile — confirm the appropriate factor for your specific application against local greywater reuse code requirements.
What this calculation does not cover
- The answer is a flow per day, not the flow an inlet actually sees. Multiplying a daily average by a peaking factor carries no duration, so it cannot tell you the flow per minute arriving when two showers and a washing machine discharge at once — size inlet pipework, filters, diverters and transfer pumps from fixture discharge rates, not from this figure.
- Nothing here sizes the cistern itself. Storage volume, retention time, drawdown against reuse demand, overflow to sewer and any make-up water arrangement are separate calculations, and greywater codes generally cap how long untreated greywater may be held before it must be used or discharged.
- No treatment or water-quality content: screening, settling, filtration, disinfection and the rules on which fixtures may feed the system (kitchen sink and dishwasher waste is excluded in many jurisdictions) are all outside the model. It is also not a compliance check — permits, cross-connection control, backflow protection and non-potable pipe labelling are set by your local greywater code.
- The peaking factor is never checked against anything: no fixture count, occupancy schedule, or code table. The result is a straight multiplication, so a factor borrowed from a different building type — or from a different peak definition, peak day versus peak hour — passes straight through to the answer with nothing flagging it.
- Daily flows outside 50–5,000 L/day (13–1,320 gal/day) and factors outside 1.5–4 are pulled back to those bounds rather than calculated. A building generating more than about 5,000 L/day of greywater cannot be entered whole; it has to be split and run per wing or per riser.
Add the equipment this sizes
This result is a specification — 325 gal/day — not a quantity. Put the thing it sizes into your project: how many, what you call it, and your supplier’s price.
Computed in your browser — nothing you enter is uploaded. Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.
Sources checked 2026-09-06 · in the site-wide review of 2026-09-06 · v1.0.1
Regulatory standards & verification citations1
- Peak inflow rate = average daily flow × peaking factor, the standard method for sizing detention/collection systems to handle short-duration peak demand rather than just the daily average
Cite this page