SettingsSettings for this calculationUS
The supply registers, diffusers, return grilles or extract terminals shown on the drawing.
The plan takeoff's vent layer sends its count here. Count supplies and returns as separate runs if their branch lengths differ much.
Your measured length from the trunk or plenum to the vent, along the joists or through the loft.
Measure the route, with the rise to the ceiling or the drop through a floor. The opening figure is a stand-in for your own; an average of a few branches measured on the plan serves for a floor of similar rooms.
Tools needed: Scale rule or the plan takeoff
Each branch starts at a collar cut into the trunk, unless the box it leaves already carries one.
A radial system fed from a plenum box with factory spigots needs no separate take-off.
Extra for the bends a branch takes and offcuts at each end.
Zero if your measured runs already include them.
Branch duct
114 ft
8 vents on their own branches, each the run you entered. The airflow, the duct sizes and the grilles' face sizes come from an HVAC design this page does not do.
- Grilles, registers or diffusers
- 8 grilles
- Register boots or plenum boxes
- 8 boots
- Take-offs at the trunk
- 8 collars
- Branch duct before the allowance
- 104 ft
They open the calculator with your figures already in it
Register, Boot and Branch Duct Calculator (Grilles and Diffusers, Boots, Take-Offs and Duct per Vent): 114 ft — shown in imperial, US market. The link sets both, so the result they see is the one on your screen.
Show calculation logicHide calculation logic
How this was calculated
Formula source(s)
- ACCA Manual D, Residential Duct Systems (3rd edition): a trunk-and-branch system in which each supply outlet is fed by its own branch run, sized from the room's airflow
- ACCA Manual T, Air Distribution Basics for Residential and Small Commercial Buildings: supply outlets and return grilles, the boot or plenum box each one is mounted on, and their selection
- Air Diffusion Council, Flexible Duct Performance and Installation Standards (5th edition): flexible duct installed fully extended, supported, with as few and as gentle bends as practical
Inputs used
- Number of Vents
- 8
- Branch Run per Vent
- 13 ft
- Count a Take-Off at the Trunk
- Yes, one per branch
- Duct Allowance (%)
- 10
Intermediate steps
- Grilles, registers or diffusers
- 8 grilles
- Register boots or plenum boxes
- 8 boots
- Take-offs at the trunk
- 8 collars
- Branch duct before the allowance
- 104 ft
Confidence note: 8 vents on their own branches, each the run you entered. The airflow, the duct sizes and the grilles' face sizes come from an HVAC design this page does not do.
What this calculation does not cover
- Nothing is sized. The airflow each terminal delivers, the branch duct's diameter and the grille's face size come from a heat-loss and duct design; the duct size, friction rate and return grille pages work those, and the design is the HVAC designer's.
- One branch per terminal, each the run you enter. A trunk duct, a shared branch that splits to two grilles, or a run of ductwork in a commercial ceiling grid is not this layout; measure the trunk on its own.
- The duct is a length, not a product. Flexible duct comes in packs and rigid duct in fixed lengths with elbows, and this page counts neither the packs nor the fittings along a branch.
- Dampers, sealing tape and mastic, hangers and insulation along the branch are separate counts; the hanger spacing and mastic pages cover two of them.
- Boots are counted at every terminal, return grilles included. A return grille fixed straight onto a framed cavity or a filter grille in a door has no boot; enter it as its own run with no take-off.
Estimated cost — your price
This site holds no price list for this material — local prices vary too much to publish honestly. Enter your supplier's price and the result is costed with it.
Computed in your browser — nothing you enter is uploaded. Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.
Sources checked 2026-10-31 · 2 test vectors · v1.0.0
Regulatory standards & verification citations3
- ACCA Manual D, Residential Duct Systems (3rd edition): a trunk-and-branch system in which each supply outlet is fed by its own branch run, sized from the room's airflow
- ACCA Manual T, Air Distribution Basics for Residential and Small Commercial Buildings: supply outlets and return grilles, the boot or plenum box each one is mounted on, and their selection
- Air Diffusion Council, Flexible Duct Performance and Installation Standards (5th edition): flexible duct installed fully extended, supported, with as few and as gentle bends as practical
Which documents these citations point at
Standards referenced: ACCA Manual D, ACCA Manual T (Air Conditioning Contractors of America, United States).
Cite this page
Your workspace
Most jobs need more than one number. Add the calculators you need next and they open right here, underneath this one — your figures stay on screen and nothing is lost to a page change.