HVAC Duct Size Calculator

Find the recommended round duct diameter for a given airflow (CFM or L/s) and target air velocity.

  • Answers as you type
  • Every formula cited
  • Calculated in your browser
SettingsSettings for this calculationUS
Market
Imperial · sales tax
The required airflow for this duct run.

This typically comes from a room-by-room load calculation or the equipment's rated CFM divided across its duct runs.

The design airflow speed through the duct.

Lower velocities (500-700 fpm) reduce noise but need larger ducts; higher velocities (800-900+ fpm) allow smaller ducts but can be noisier — main trunk lines and branch runs are often designed differently.

Recommended round duct diameter

10.2 in (round duct diameter)

Medium confidence

This sizes for velocity only — a full duct design also accounts for static pressure and total system friction loss (duct length, fittings, filters) using manufacturer duct-sizing charts.

Required cross-sectional area
0.57 sq ft
Then change the inputs to see how far the answer moves.

Show calculation logic

How this was calculated

Formula source(s)

  • Standard duct sizing formula: cross-sectional area (sq ft) = CFM / velocity (ft/min); round duct diameter = sqrt(4 x area / pi)
  • Common design velocity for residential supply ducts is roughly 700-900 ft/min; return ducts are often designed slightly lower

Inputs used

Airflow
400 CFM
Target air velocity
700 ft/min

Intermediate steps

Required cross-sectional area
0.57 sq ft
Final result10.24 in (round duct diameter)

Confidence note: This sizes for velocity only — a full duct design also accounts for static pressure and total system friction loss (duct length, fittings, filters) using manufacturer duct-sizing charts.

What this calculation does not cover

  • Velocity is the entire model. The diameter comes from airflow divided by the speed you type, with no friction rate, no duct length, no elbows or takeoffs and no filter or coil resistance in it, so a run sized here can still be one the blower cannot push its rated air through.
  • This sizes one duct run; it is not a duct system design and not an ACCA Manual D. It produces no total effective length, no available static pressure and no friction rate, so where a permit, an energy-code compliance path or an equipment warranty calls for a documented duct design, this does not stand in for one.
  • The answer is a theoretical diameter, not a size you can buy. Round pipe and flex come in fixed increments and nothing here steps the result onto one — take the next size up, because dropping to the size below raises velocity, noise and pressure loss at the same time.
  • Duct material and condition are not part of the calculation. Flexible duct is rougher than smooth galvanised pipe at the same nominal diameter, and rougher again where it is left compressed, sagging or coiled between supports, so the same figure on this page does not deliver the same air in every material.
  • Nothing checks the velocity you entered against a noise limit. The number is taken as a design choice, and whether the run will be audible in the room depends on the fittings, the register and how close the duct passes to occupied space — none of which this calculation sees.

Add the equipment this sizes

This result is a specification — 10.2 in (round duct diameter) — not a quantity. Put the thing it sizes into your project: how many, what you call it, and your supplier’s price.

Computed in your browser — nothing you enter is uploaded. Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.

Sources checked 2026-09-02 · in the site-wide review of 2026-09-06 · v1.0.1

Regulatory standards & verification citations2
  1. Standard duct sizing formula: cross-sectional area (sq ft) = CFM / velocity (ft/min); round duct diameter = sqrt(4 x area / pi)
  2. Common design velocity for residential supply ducts is roughly 700-900 ft/min; return ducts are often designed slightly lower
Cite this page

Your workspace

Most jobs need more than one number. Add the calculators you need next and they open right here, underneath this one — your figures stay on screen and nothing is lost to a page change.

Now that you have the number

These guides cover the work this quantity is for — the first ones run this calculator inside the section that raises the question.

How to calculate HVAC duct size in 3 steps

  1. AirflowThe required airflow for this duct run.
  2. Target air velocityThe design airflow speed through the duct.
  3. Recommended round duct diameterThe tool computes the recommended round duct diameter from those figures and shows the formula, its sources, and a confidence rating alongside it.

Recommended round duct diameter by airflow

Page defaults, not your figures above.

AirflowRecommended round duct diameter (in (round duct diameter))
200 CFM7.24
300 CFM8.86
400 CFM10.2
500 CFM11.4
600 CFM12.5
700 CFM13.5
800 CFM14.5

Frequently asked questions

How do I convert this to a rectangular duct size?
Use a duct equivalent-diameter conversion chart or calculator to find a rectangular duct (e.g. for tight spaces above a ceiling) with the same effective cross-sectional airflow capacity as this round diameter.
Why does velocity choice matter beyond just fitting the duct?
Higher velocities let you use smaller, cheaper ducts but increase both noise and static pressure (which taxes the blower motor) — main trunk lines and long branch runs are often designed toward the lower end of the velocity range for this reason.
Does this replace a Manual D duct design?
No — this estimates one duct run's size from velocity alone. A full residential duct system design (ACCA Manual D) also balances total system static pressure, fitting losses, and blower capability across all runs together.
Preliminary estimate, not certified engineering. This tool produces an indicative quantity calculation for planning purposes only — it is not a certified structural analysis, a guaranteed material takeoff, or a substitute for building department approval. Always verify measurements on-site and have a licensed contractor or structural engineer review any load-bearing, code-sensitive, or safety-critical work before purchasing materials or starting construction. Spotted an arithmetic or standards error? Report it to contact@craftquantities.com with your inputs — a confirmed fix gets a permanent check of its own, so the same mistake cannot come back.