  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "hvac-duct-cfm-calculator",
  "category": "plumbing-hvac",
  "title": "HVAC Duct Size Calculator",
  "description": "Find the recommended round duct diameter for a given airflow (CFM or L/s) and target air velocity.",
  "url": "https://craftquantities.com/calculators/plumbing-hvac/hvac-duct-cfm-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/hvac-duct-cfm-calculator.json",
  "inputCount": 2,
  "testCaseCount": 2,
  "sourceCount": 2,
  "lastVerified": "2026-09-02",
  "translations": {
    "es-US": "https://craftquantities.com/es/calculators/plumbing-hvac/hvac-duct-cfm-calculator/"
  },
  "citation": {
    "author": "Craft Quantities",
    "title": "HVAC Duct Size Calculator",
    "version": "1.0.1",
    "sourcesChecked": "2026-09-02",
    "url": "https://craftquantities.com/calculators/plumbing-hvac/hvac-duct-cfm-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. HVAC Duct Size Calculator. Version 1.0.1. Sources checked 2026-09-02. https://craftquantities.com/calculators/plumbing-hvac/hvac-duct-cfm-calculator/",
      "apa": "Craft Quantities. (2026). HVAC Duct Size Calculator (Version 1.0.1) [Web calculator]. Retrieved from https://craftquantities.com/calculators/plumbing-hvac/hvac-duct-cfm-calculator/",
      "harvard": "Craft Quantities (2026) HVAC Duct Size Calculator (Version 1.0.1). Available at: https://craftquantities.com/calculators/plumbing-hvac/hvac-duct-cfm-calculator/",
      "bibtex": "@misc{craftquantities-calculators-plumbing-hvac-hvac-duct-cfm-calculator,\n  author       = {{Craft Quantities}},\n  title        = {HVAC Duct Size Calculator},\n  version      = {1.0.1},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/plumbing-hvac/hvac-duct-cfm-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "cfm",
      "label": "Airflow",
      "type": "number",
      "dimension": "airflow",
      "defaultValue": 188.779,
      "min": 9.4389,
      "max": 2359.7372,
      "step": 4.7195,
      "help": "The required airflow for this duct run."
    },
    {
      "id": "targetVelocityFpm",
      "label": "Target air velocity",
      "type": "number",
      "dimension": "velocity",
      "defaultValue": 3.556,
      "min": 1.524,
      "max": 7.62,
      "step": 0.254,
      "help": "The design airflow speed through the duct."
    }
  ],
  "sources": [
    {
      "label": "Standard duct sizing formula: cross-sectional area (sq ft) = CFM / velocity (ft/min); round duct diameter = sqrt(4 x area / pi)"
    },
    {
      "label": "Common design velocity for residential supply ducts is roughly 700-900 ft/min; return ducts are often designed slightly lower"
    }
  ],
  "testCases": [
    {
      "name": "400 CFM at 700 fpm",
      "inputs": {
        "cfm": 188.779,
        "targetVelocityFpm": 3.556
      },
      "expected": 10.236,
      "toleranceDecimalPlaces": 0.2,
      "unit": "in (round duct diameter)",
      "confidence": "medium",
      "steps": [
        {
          "label": "Required cross-sectional area",
          "value": 0.5714286402013624,
          "unit": "sq ft"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "800 CFM at 900 fpm",
      "inputs": {
        "cfm": 377.558,
        "targetVelocityFpm": 4.572
      },
      "expected": 12.767,
      "toleranceDecimalPlaces": 0.2,
      "unit": "in (round duct diameter)",
      "confidence": "medium",
      "steps": [
        {
          "label": "Required cross-sectional area",
          "value": 0.8888889958687859,
          "unit": "sq ft"
        }
      ],
      "basis": "ambiguous"
    }
  ]
}