SettingsSettings for this calculationUS
Your household's estimated daily wastewater flow, in the unit shown.
A common rule of thumb is about 570 L (150 gallons) per bedroom per day — check the Septic Tank Sizing Calculator's bedroom-based tank sizing for a related reference point.
How quickly water drains through your soil, from a percolation ('perc') test.
A licensed soil evaluator or septic installer performs a percolation test as part of the permitting process — slower-draining soil needs a larger absorption area for the same wastewater flow.
Estimated drain field area needed
670 sq ft (estimated absorption area)
This is a very general planning estimate using broad percolation categories — actual drain field design requires a licensed soil evaluator's specific percolation test results and must follow your local health department's exact sizing tables and setback requirements before any permit is issued.
They open the calculator with your figures already in it
Septic Drain Field Sizing Calculator: 667 sq ft (estimated absorption area) — shown in imperial, US market. The link sets both, so the result they see is the one on your screen.
Show calculation logicHide calculation logic
How this was calculated
Formula source(s)
- Required absorption area = daily wastewater flow ÷ soil application rate (the rate tables are published in gal/day/sq ft; metric inputs convert at the boundary); application rate is commonly categorized by percolation test results (faster-draining soil allows a higher application rate)
Inputs used
- Estimated Daily Wastewater Flow
- 400 gal
- Soil Percolation Rate
- Moderate (10-30 min/in)
Confidence note: This is a very general planning estimate using broad percolation categories — actual drain field design requires a licensed soil evaluator's specific percolation test results and must follow your local health department's exact sizing tables and setback requirements before any permit is issued.
What this calculation does not cover
- This does not replace a percolation test, and it applies none of the site checks that decide whether a conventional gravity field is allowed at all — depth to the seasonal high water table, to bedrock or to a hardpan layer, and the vertical separation required beneath the trench bottom. The permitted area is whatever the governing health authority's own loading table returns for a measured rate, and that table overrides this figure.
- The four soil options each carry one flat loading rate, so every measured rate inside a band returns the same area and the answer only moves when a band edge is crossed. Nothing bounds the extremes either: 'fast draining' has no lower limit, and the 'very slow' option still returns a number for soil beyond 60 min/in, where a conventional gravity field frequently is not the design that gets permitted.
- The figure is infiltrative surface — trench-bottom or bed area on undisturbed soil — and nothing more. It carries no trench width, length, spacing or lateral count, no stone or chamber depth, and no distribution or dosing arrangement, and it applies none of the area credits some jurisdictions allow for sidewall or for chamber and gravelless products. It also excludes the reserve area and the setbacks from wells, water bodies, property lines and foundations that decide whether the field fits the lot.
- Daily flow enters as one flat average. No peaking factor is applied, and nothing adjusts for a garbage disposal, water softener backwash, a hot tub, seasonal or intermittent occupancy, or clear-water sources leaking into the system. Most codes set design flow from bedroom count rather than from metered use, so entering a low real-world figure does not earn a smaller field.
- Nothing here accounts for how the field ages or how the ground is treated. The biomat that forms at the infiltrative surface, effluent quality from a tank with no working filter or an overdue pump-out, slope and landscape position, depth of cover, and compaction from plant or construction traffic all change what the soil will keep accepting, and none of them is an input.
Estimated cost — your price
This site holds no price list for this material — local prices vary too much to publish honestly. Enter your supplier's price and the result is costed with it.
Computed in your browser — nothing you enter is uploaded. Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.
Sources checked 2026-09-02 · in the site-wide review of 2026-09-06 · v1.1.1
Regulatory standards & verification citations1
- Required absorption area = daily wastewater flow ÷ soil application rate (the rate tables are published in gal/day/sq ft; metric inputs convert at the boundary); application rate is commonly categorized by percolation test results (faster-draining soil allows a higher application rate)
Cite this page
Your workspace
Most jobs need more than one number. Add the calculators you need next and they open right here, underneath this one — your figures stay on screen and nothing is lost to a page change.
Tools and safety for this job
To cut and join plastic pipe. Generic types, no brands, no prices.
Protection this work requires
- Knives cause more site injuries than any power tool: cut away from your body, change blades often, and wear cut-resistant gloves to EN 388 level C for repeated cutting.
Cut and join plastic pipe: Push-fit and solvent-weld plumbing is within reach of a competent DIYer. The regulated parts of the system — gas, unvented hot water, and anything notifiable — are not, whatever tools are to hand.
Show the 3 tools this job needsHide tools
Essential
Plastic pipe shears
Tape measure
Recommended
Deburring tool and wire wool
what each plumbing tool is for, and the spec that decides which to buy where one does.