  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "register-boot-duct-calculator",
  "category": "plumbing-hvac",
  "title": "Register, Boot and Branch Duct Calculator (Grilles and Diffusers, Boots, Take-Offs and Duct per Vent)",
  "description": "From a count of supply registers or vents: grilles, register boots, take-offs and branch duct on your own measured run.",
  "url": "https://craftquantities.com/calculators/plumbing-hvac/register-boot-duct-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/register-boot-duct-calculator.json",
  "inputCount": 4,
  "testCaseCount": 2,
  "sourceCount": 3,
  "lastVerified": "2026-10-31",
  "citation": {
    "author": "Craft Quantities",
    "title": "Register, Boot and Branch Duct Calculator (Grilles and Diffusers, Boots, Take-Offs and Duct per Vent)",
    "version": "1.0.0",
    "sourcesChecked": "2026-10-31",
    "url": "https://craftquantities.com/calculators/plumbing-hvac/register-boot-duct-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Register, Boot and Branch Duct Calculator (Grilles and Diffusers, Boots, Take-Offs and Duct per Vent). Version 1.0.0. Sources checked 2026-10-31. https://craftquantities.com/calculators/plumbing-hvac/register-boot-duct-calculator/",
      "apa": "Craft Quantities. (2026). Register, Boot and Branch Duct Calculator (Grilles and Diffusers, Boots, Take-Offs and Duct per Vent) (Version 1.0.0) [Web calculator]. Retrieved from https://craftquantities.com/calculators/plumbing-hvac/register-boot-duct-calculator/",
      "harvard": "Craft Quantities (2026) Register, Boot and Branch Duct Calculator (Grilles and Diffusers, Boots, Take-Offs and Duct per Vent) (Version 1.0.0). Available at: https://craftquantities.com/calculators/plumbing-hvac/register-boot-duct-calculator/",
      "bibtex": "@misc{craftquantities-calculators-plumbing-hvac-register-boot-duct-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Register, Boot and Branch Duct Calculator (Grilles and Diffusers, Boots, Take-Offs and Duct per Vent)},\n  version      = {1.0.0},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/plumbing-hvac/register-boot-duct-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "ventCount",
      "label": "Number of Vents",
      "type": "number",
      "defaultValue": 8,
      "min": 1,
      "max": 300,
      "step": 1,
      "help": "The supply registers, diffusers, return grilles or extract terminals shown on the drawing."
    },
    {
      "id": "branchRun",
      "label": "Branch Run per Vent",
      "type": "number",
      "dimension": "length",
      "defaultValue": 4,
      "min": 0.1,
      "max": 50,
      "step": 0.1,
      "help": "Your measured length from the trunk or plenum to the vent, along the joists or through the loft."
    },
    {
      "id": "takeOffs",
      "label": "Count a Take-Off at the Trunk",
      "type": "select",
      "defaultValue": "yes",
      "options": [
        {
          "value": "yes",
          "label": "Yes, one per branch"
        },
        {
          "value": "no",
          "label": "No, the box has spigots"
        }
      ],
      "help": "Each branch starts at a collar cut into the trunk, unless the box it leaves already carries one."
    },
    {
      "id": "allowancePercent",
      "label": "Duct Allowance (%)",
      "type": "number",
      "defaultValue": 10,
      "min": 0,
      "max": 50,
      "step": 1,
      "help": "Extra for the bends a branch takes and offcuts at each end."
    }
  ],
  "sources": [
    {
      "label": "ACCA Manual D, Residential Duct Systems (3rd edition): a trunk-and-branch system in which each supply outlet is fed by its own branch run, sized from the room's airflow",
      "url": "https://www.acca.org/standards/technical-manuals/manual-d"
    },
    {
      "label": "ACCA Manual T, Air Distribution Basics for Residential and Small Commercial Buildings: supply outlets and return grilles, the boot or plenum box each one is mounted on, and their selection",
      "url": "https://www.acca.org/standards/technical-manuals/manual-t"
    },
    {
      "label": "Air Diffusion Council, Flexible Duct Performance and Installation Standards (5th edition): flexible duct installed fully extended, supported, with as few and as gentle bends as practical",
      "url": "https://flexibleduct.org/"
    }
  ],
  "testCases": [
    {
      "name": "8 supply registers, 4 m branches, 10%: 35.2 m of duct",
      "inputs": {
        "ventCount": 8,
        "branchRun": 4,
        "takeOffs": "yes",
        "allowancePercent": 10
      },
      "expected": 35.2,
      "toleranceDecimalPlaces": 2,
      "unit": "m",
      "confidence": "medium",
      "steps": [
        {
          "label": "Grilles, registers or diffusers",
          "value": 8,
          "unit": "grilles"
        },
        {
          "label": "Register boots or plenum boxes",
          "value": 8,
          "unit": "boots"
        },
        {
          "label": "Take-offs at the trunk",
          "value": 8,
          "unit": "collars"
        },
        {
          "label": "Branch duct before the allowance",
          "value": 32,
          "unit": "m"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "10 vents, 12 ft branches, no allowance: 120 ft of duct",
      "inputs": {
        "ventCount": 10,
        "branchRun": 3.6576000000000004,
        "takeOffs": "no",
        "allowancePercent": 0
      },
      "expected": 36.576,
      "toleranceDecimalPlaces": 2,
      "unit": "m",
      "confidence": "medium",
      "steps": [
        {
          "label": "Grilles, registers or diffusers",
          "value": 10,
          "unit": "grilles"
        },
        {
          "label": "Register boots or plenum boxes",
          "value": 10,
          "unit": "boots"
        },
        {
          "label": "Take-offs at the trunk",
          "value": 0,
          "unit": "collars"
        },
        {
          "label": "Branch duct before the allowance",
          "value": 36.57600000000001,
          "unit": "m"
        }
      ],
      "basis": "cited",
      "sourceIndex": 2
    }
  ]
}