Wood Load Duration Factor (CD) Adjustment Calculator
Apply the NDS load duration factor (CD) to adjust an allowable wood design value for the governing load type.
Computed in your browser — nothing you enter is uploaded. Figures are presented for United States against IRC 2024, and every formula is cited under regulatory standards below.
Last verified 2026-08-26 · v1.0.0
Adjusted design value
1150 (CD factor)
- CD factor applied
- 1.15
Running these inputs gives 1150 (CD factor) as the adjusted design value. Currently reading for United States under IRC 2024 — pick a different market above and the figures re-cast accordingly.
[Schema Verified] Computed in alignment with American Concrete Institute (ACI 318-19) formulas and International Residential Code (IRC 2024) spatial boundaries.
Regulatory standards & verification citations
- NDS (National Design Specification for Wood Construction) Table 2.3.2 load duration factors: CD = 0.9 (permanent/dead), 1.0 (ten-year/normal floor), 1.15 (two-month/snow), 1.25 (seven-day/construction & roof live), 1.6 (ten-minute/wind & seismic), 2.0 (impact)