SettingsSettings for this calculationUS
How far the winders turn the stair.
A half turn is two quarter turns of winders round one newel.
Three is the common kite turn; two gives deeper winders.
The NCC allows at most 3 for a quarter landing; the NBC allows 30° or 45° each (3 or 2).
Where each nosing line meets the newel.
Fanned lines give equal angles; spaced lines give every winder the same narrow end; balanced treads spread the taper over the turn and into both flights, every one the straight going on the walk line. A balanced layout turns a quarter. Round an open well there is no newel: the winders fan from the well's centre and the inner string curves round it.
The flight's width from the newel's centre line to the wall.
The clear width is this less half the newel.
The post at the inside corner; 0 for a wall corner.
A bigger newel gives wider narrow ends.
0 sets it in the middle of the clear width.
Where the winders' goings are made equal; each code then reads them at its own point.
The stair's riser, each winder one up.
From the straight flights: the stair rise and run page gives it.
For the comparison with the winders.
Approved Document K 1.27 asks that tapered treads go no less than the straight ones.
Added to each blank's front edge if the treads overhang.
The blanks are drawn nosing to nosing; this is noted on them.
The code the winders are read against, each at its own measuring point.
Figures compared with the code's own, never compliance: the building official or building control body decides. Where this page does not read a code's figures it says so rather than guessing them.
Going of each winder on the walk line
14.5 in
≈ 14 9/16 in
WITHIN THE LIMITS CHECKED — 2 winders, 272 mm (10.72 in) each deep at the walk line, 12 in (305 mm) from the narrow side, narrow ends from 51 mm (2.00 in), inside the figures this page reads for IRC R311.7.5.2.1. Limits checked, not an approval. At the newel the narrowest end is 51 mm (2.00 in): the part of each winder under 6 in (152 mm) deep must be the newel's or outside the clear width (R311.7.5.2.1).
- Winders
- 2 winders
- Least going at the code's measuring point
- 10.72 in · 10 11/16 in
- Narrowest end at the newel
- 2 in
- Widest blank's wide end
- 36 in
- Largest blank, board length
- 49.5 in · 49 1/2 in
- Largest blank, board depth
- 36 in
- Area of all the blanks
- 8.97 sq ft
- Rise through the turn
- 14.5 in · 14 1/2 in
They open the calculator with your figures already in it
Winder Stair Calculator (Kite, Balanced and Dancing Winders, Quarter and Half Turns: Each Set Out): 14.54 in — shown in imperial, US market. The link sets both, so the result they see is the one on your screen.
Show calculation logicHide calculation logic
How this was calculated
Formula source(s)
- US: IRC R311.7.5.2.1 — winder treads at least 10 in deep at the walk line, 12 in from the narrow side, and at least 6 in at any point within the clear width
- UK: Approved Document K (2013 edition), paragraphs 1.25–1.27 and Diagram 1.9 — the going of tapered treads measured at the middle of a stair under 1 m wide (270 mm in from each side of a wider one), 50 mm least at the narrow end, consecutive tapered treads the same going, and not less than the straight treads' going; Table 1.1 for a private stair's going (220–300 mm)
- Australia: NCC 2022 Housing Provisions 11.2.2(3) — up to 3 consecutive winders in place of a quarter landing and up to 6 in place of a half, their going constant; Table 11.2.2a going 240–355 mm
- Canada: National Building Code 9.8.4.6 — winders turning 30° or 45°, a set turning no more than 90°, read as this site's L- and U-shaped stair page reads them
- Each nosing line through a point on the setting-out walk line at equal angles of the turn; the going at a radius is the distance between two lines' crossings of that circle
Inputs used
- Turn
- Quarter turn (90°, an L)
- Winders in each quarter turn
- 2
- Layout at the newel
- Fanned from the newel's centre (kite)
- Open well diameter
- 16 in
- Curved string depth
- 10.75 in
- Curved string thickness
- 1.75 in
- Ply thickness, if laminated
- 0.25 in
- Tread thickness
- 1.25 in
- Balanced treads in all
- 7
- Stair width (newel centre line to the wall)
- 3 ft
- Newel post (square)
- 4 in
- Setting-out walk line from the newel's face
- 0 in
- Riser height
- 7.25 in
- Going of the straight treads
- 10.25 in
- Nosing projection
- 1 in
- Code for the readout
- US — IRC
Intermediate steps
- Winders
- 2 winders
- Least going at the code's measuring point
- 10.72 in
- Narrowest end at the newel
- 2 in
- Widest blank's wide end
- 36 in
- Largest blank, board length
- 49.5 in
- Largest blank, board depth
- 36 in
- Area of all the blanks
- 8.97 sq ft
- Rise through the turn
- 14.5 in
Confidence note: WITHIN THE LIMITS CHECKED — 2 winders, 272 mm (10.72 in) each deep at the walk line, 12 in (305 mm) from the narrow side, narrow ends from 51 mm (2.00 in), inside the figures this page reads for IRC R311.7.5.2.1. Limits checked, not an approval. At the newel the narrowest end is 51 mm (2.00 in): the part of each winder under 6 in (152 mm) deep must be the newel's or outside the clear width (R311.7.5.2.1).
What this calculation does not cover
- This sets winders out; it does not approve a turn. Each code measures winders at its own point and some limit how many may replace a landing: the readout compares, your building official decides.
- The newel, the bearers or carriages under the winders and their housings are the joiner's or your engineer's to size; the newel's size here only places the narrow ends.
- The winders fill a square turn (two for a half turn) the stair's width on a side, round a square newel or a circular open well; balanced (dancing) winders are set out for a quarter turn only, and a well that is not circular is not set out here.
- Round an open well the nosings are radial from the well's centre and the inner string is a wreath bent or cut to the well: its unrolled template, plies and plank are geometry; whether a string of that depth and thickness carries the stair, and its joints to the straight strings, are the stair maker's or your engineer's.
- Distances "from the narrow side" are read as radii from the newel's centre, half the newel plus the code's distance; on a square newel the true distance differs a little near the corner.
- Blanks are the walking surfaces nosing to nosing; the nosing projection, the housing into the walls and the newel, and the bearers under each winder are the joiner's.
Add the equipment this sizes
This result is a specification — 14.5 in — not a quantity. Put the thing it sizes into your project: how many, what you call it, and your supplier’s price.
Computed in your browser — nothing you enter is uploaded. Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.
Sources checked 2026-11-13 · 8 test vectors · v1.0.0
Regulatory standards & verification citations5
- US: IRC R311.7.5.2.1 — winder treads at least 10 in deep at the walk line, 12 in from the narrow side, and at least 6 in at any point within the clear width
- UK: Approved Document K (2013 edition), paragraphs 1.25–1.27 and Diagram 1.9 — the going of tapered treads measured at the middle of a stair under 1 m wide (270 mm in from each side of a wider one), 50 mm least at the narrow end, consecutive tapered treads the same going, and not less than the straight treads' going; Table 1.1 for a private stair's going (220–300 mm)
- Australia: NCC 2022 Housing Provisions 11.2.2(3) — up to 3 consecutive winders in place of a quarter landing and up to 6 in place of a half, their going constant; Table 11.2.2a going 240–355 mm
- Canada: National Building Code 9.8.4.6 — winders turning 30° or 45°, a set turning no more than 90°, read as this site's L- and U-shaped stair page reads them
- Each nosing line through a point on the setting-out walk line at equal angles of the turn; the going at a radius is the distance between two lines' crossings of that circle
Which documents these citations point at
- International Residential Code — R311.7.5.2.1 (United States)One- and two-family dwellings and townhouses up to three storeys — structure, fire safety, energy, plumbing, mechanical and electrical in a single document.
- Approved Documents to the Building Regulations (England) — K (United Kingdom)Practical guidance on meeting the Building Regulations, one lettered part per subject — Part A structure, Part B fire, Part K protection from falling, Part L conservation of fuel and power, and the rest.
A code or standard has force only where a jurisdiction has adopted it, usually with local amendments. This site holds no adoption data for any authority, so check what is in force with the authority where you build. Any section cited above without an edition should be checked against the edition in force where you build. What it would take to know.
Cite this page
Your workspace
Most jobs need more than one number. Add the calculators you need next and they open right here, underneath this one — your figures stay on screen and nothing is lost to a page change.
The turn drawn and every winder set out
A scaled plan of the turn with each winder numbered round the newel, every blank's angle, narrow and wide ends, nosing edge and the board it is cut from, and each code's going at its own measuring point.
Full-size winder templates
Print every winder blank at full size, numbered, with its nosing edge and walk line marked, or the whole turn on plan as a setting-out board, tiled over A4 or Letter with a calibration square on every sheet.