SettingsSettings for this calculationUS
The standard allowance most suppliers and estimating guides assume for ordinary work.
A column at the centre, or an open well.
The geometry is the same; the codes read them differently. The IRC sets spiral stairs on their own (R311.7.10.1) and reads a curved stair's treads as winders.
Finished floor below to finished floor above.
Measured on site with the finishes each floor will carry; the risers share it equally.
The rise per step you want.
The count of risers is the total rise over this, rounded up, so no riser is taller; the IRC allows a spiral stair 9 1/2 in, the NCC's spiral row 220 mm.
Across the stair from tread end to tread end.
Kits are sold by this figure. The opening above is at least this across.
The column a spiral stair turns on, or a helical stair's well.
The treads run from this circle to the outer one; the narrow end of each tread is here.
Degrees the walking treads turn through, first riser to the landing's front edge.
Shared over the treads, it sets each tread's angle: the more the stair turns, the deeper each tread and the more headroom one turn up.
The angle the top landing sweeps; 0 if the upper floor's edge is the last step.
A 90° landing is common on kits. It sits over the first treads one turn down, so a longer landing costs headroom there.
The tread's own thickness, for the headroom under it.
A tread on brackets or a stringer takes the depth of those as well; enter the whole depth to read headroom to its underside.
Measured along the outer edge.
Adds to each blank's sweep; 0 for treads that meet edge to edge.
Upper floor to the ceiling below it.
With the headroom, it sets how much of the circle the floor above must leave open.
Clear height over the treads under the floor above.
Opens on 6 ft 6 in (1981 mm), the IRC's spiral figure; the opening is worked for the figure entered.
One baluster's face.
Spaced on the outer edge so the gap stays inside the 4 in (100 mm) sphere.
Rails to develop and buy.
A helical stair's well usually takes an inner rail too.
Spares on what is cut to length or counted.
Treads are cut to one blank and take none.
The code the riser, going, width and headroom are read against.
Figures compared with the code's own, never compliance: the building official or building control body decides. Where this page does not read a code's figures it says so rather than guessing them.
Treads
13 treads
WITHIN THE LIMITS CHECKED — clear width 692 mm (27.25 in), riser 196 mm (7.71 in), going 179 mm (7.06 in) at the walk line 12 in (305 mm) from the narrow edge, 2117 mm (83.36 in) of headroom one turn up, inside the figures this page reads for IRC R311.7.10.1. Limits checked, not an approval. Every tread here is the same blank, as R311.7.10.1 asks; the handrail's projection into the clear width is the maker's detail and is not taken off.
- Risers
- 14 risers
- Riser height
- 7.71 in · 7 11/16 in
- Tread angle, nosing to nosing
- 27.69 °
- Going at the code's measuring point
- 7.06 in · 7 1/16 in
- Going at the narrow end
- 1.32 in · 1 5/16 in
- Going at the outer edge
- 14.36 in · 14 3/8 in
- Clear width, column to outer edge
- 27.25 in · 27 1/4 in
- Least headroom one turn up
- 6.95 ft · 6 ft 11 3/8 in
- Opening in the floor above, sweep
- 360 °
- Outer handrail, developed
- 17.79 ft · 17 ft 9 1/2 in
- Tread blank, area each
- 1.63 sq ft
- Balusters on the outer edge
- 43 balusters
They open the calculator with your figures already in it
Spiral Staircase Calculator (Spiral, Helical and Curved Stairs: Treads, Going, Headroom and Handrail): 13 treads — shown in imperial, US market. The link sets both, so the result they see is the one on your screen.
Show calculation logicHide calculation logic
How this was calculated
Formula source(s)
- US: IRC R311.7.10.1 (2018 and later), spiral stairways — clear width at and below the handrail at least 26 in, walk-line radius at most 24 1/2 in, each tread at least 6 3/4 in deep at the walk line, treads identical, rise at most 9 1/2 in, headroom at least 6 ft 6 in; R311.7.5.2.1 for a curved stair's treads (winders: 10 in at the walk line, 6 in at any point)
- Australia: NCC 2022 Housing Provisions 11.2.2(4)(b) and Table 11.2.2a, spiral row — riser 140–220 mm, going 210–370 mm, 2R + G 590–680 mm, the going measured seven tenths of the unobstructed width out from the face of the centre pole
- UK: Approved Document K (2013 edition), paragraph 1.28 — spiral and helical stairs designed in accordance with BS 5395-2
- Developed helix length = sqrt((radius x rotation in radians)^2 + rise^2), the unrolled helix of this site's Spiral Stair Helix Geometry Calculator; a chord between two radial lines at radius r = 2 r sin(theta / 2)
Inputs used
- Kind of stair
- Spiral — treads round a centre column
- Total Rise (floor to floor)
- 9 ft
- Riser You Are Aiming For
- 8 in
- Outer diameter (to the treads' outer edge)
- 5 ft
- Inner diameter (column, or the open well)
- 5.5 in
- Rotation of the treads (°)
- 360
- Landing platform at the top (°)
- 60
- Tread thickness
- 1.5 in
- Overlap of each tread over the one below
- 1.25 in
- Floor depth at the opening
- 9.75 in
- Headroom to keep
- 78 in
- Baluster width
- 1 in
- Handrails
- Outer edge
- Curved string depth
- 10.75 in
- Curved string thickness
- 1.75 in
- Ply thickness, if laminated
- 0.25 in
- Allowance on balusters and rails (%)
- 10
- Code for the readout
- US — IRC
Intermediate steps
- Risers
- 14 risers
- Riser height
- 7.71 in
- Tread angle, nosing to nosing
- 27.69 °
- Going at the code's measuring point
- 7.06 in
- Going at the narrow end
- 1.32 in
- Going at the outer edge
- 14.36 in
- Clear width, column to outer edge
- 27.25 in
- Least headroom one turn up
- 6.95 ft
- Opening in the floor above, sweep
- 360 °
- Outer handrail, developed
- 17.79 ft
- Tread blank, area each
- 1.63 sq ft
- Balusters on the outer edge
- 43 balusters
Confidence note: WITHIN THE LIMITS CHECKED — clear width 692 mm (27.25 in), riser 196 mm (7.71 in), going 179 mm (7.06 in) at the walk line 12 in (305 mm) from the narrow edge, 2117 mm (83.36 in) of headroom one turn up, inside the figures this page reads for IRC R311.7.10.1. Limits checked, not an approval. Every tread here is the same blank, as R311.7.10.1 asks; the handrail's projection into the clear width is the maker's detail and is not taken off.
What this calculation does not cover
- This lays a spiral or helical stair out; it does not approve one. The width, riser, going and headroom it reads are your code's, checked by your building official, and a kit maker's own figures govern a kit.
- The column, the treads' thickness, their brackets and the landing's fixing to the floor are the maker's or your engineer's: entered, never sized, and nothing here says they carry the stair.
- Goings are chords between radial nosings; a tread cut with a curved or skewed nosing has other goings, and a kit's own drawing governs a kit.
- Headroom one turn up is to the underside of the tread overhead as entered (its thickness); a stringer, a soffit or a bracket under it takes more, and the floor opening is worked for the headroom you enter, measured on site.
- The rail lengths are developed helices at the outer edge and the inner line; a rail set in from the edge, its returns at the landing and the guard round the opening are not added.
- A helical stair's curved strings are unrolled on the faces the treads are housed into, plumb-cut where they spring; the joints to the floor and the landing, the former they are bent on and whether their depth and thickness carry the stair are the maker's or your engineer's.
Estimated cost — your price
This site holds no price list for this material — local prices vary too much to publish honestly. Enter your supplier's price and the result is costed with it.
Part of a bigger job
Or plan the space itself: measure it once, doors and windows included, and this figure comes back worked out on that space, with what goes with it.
Computed in your browser — nothing you enter is uploaded. Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.
Sources checked 2026-11-13 · 6 test vectors · v1.0.0
Regulatory standards & verification citations4
- US: IRC R311.7.10.1 (2018 and later), spiral stairways — clear width at and below the handrail at least 26 in, walk-line radius at most 24 1/2 in, each tread at least 6 3/4 in deep at the walk line, treads identical, rise at most 9 1/2 in, headroom at least 6 ft 6 in; R311.7.5.2.1 for a curved stair's treads (winders: 10 in at the walk line, 6 in at any point)
- Australia: NCC 2022 Housing Provisions 11.2.2(4)(b) and Table 11.2.2a, spiral row — riser 140–220 mm, going 210–370 mm, 2R + G 590–680 mm, the going measured seven tenths of the unobstructed width out from the face of the centre pole
- UK: Approved Document K (2013 edition), paragraph 1.28 — spiral and helical stairs designed in accordance with BS 5395-2
- Developed helix length = sqrt((radius x rotation in radians)^2 + rise^2), the unrolled helix of this site's Spiral Stair Helix Geometry Calculator; a chord between two radial lines at radius r = 2 r sin(theta / 2)
Which documents these citations point at
- International Residential Code — R311.7.10.1 (United States)One- and two-family dwellings and townhouses up to three storeys — structure, fire safety, energy, plumbing, mechanical and electrical in a single document.
- Approved Documents to the Building Regulations (England) — K (United Kingdom)Practical guidance on meeting the Building Regulations, one lettered part per subject — Part A structure, Part B fire, Part K protection from falling, Part L conservation of fuel and power, and the rest.
A code or standard has force only where a jurisdiction has adopted it, usually with local amendments. This site holds no adoption data for any authority, so check what is in force with the authority where you build. Any section cited above without an edition should be checked against the edition in force where you build. What it would take to know.
Cite this page
Your workspace
Most jobs need more than one number. Add the calculators you need next and they open right here, underneath this one — your figures stay on screen and nothing is lost to a page change.
The stair drawn, set out and counted
A scaled elevation and plan of the stair, each tread numbered with the walk line and the landing, the going at your code's measuring point, the headroom one turn up, the opening above, the developed rails, and the parts, with the code readout.
Full-size tread template
Print one tread blank at full size — cut it, repeat it for every tread — with the overlap line, the walk line and the column's centre marked, or the landing platform, tiled over A4 or Letter with a calibration square on every sheet.