Materials & Quantities

Spiral Staircase Calculator (Spiral, Helical and Curved Stairs: Treads, Going, Headroom and Handrail)

Spiral or helical stair from your rise, diameters and turn: risers, tread angle, walk-line going, headroom one turn up, rails and a full-size tread.

Treads: 13 treads for Total Rise 9 ft, Riser You Are Aiming For 8 in and Outer diameter 5 ft, the page's opening figures; on the metric page, 2.7 m, 205 mm and 1.6 m give 13 treads. Source: US.

  • Answers as you type
  • 4 sources cited
  • Calculated in your browser
SettingsSettings for this calculationUS
Market
Imperial · sales tax
Who is doing the work?

The standard allowance most suppliers and estimating guides assume for ordinary work.

A column at the centre, or an open well.

The geometry is the same; the codes read them differently. The IRC sets spiral stairs on their own (R311.7.10.1) and reads a curved stair's treads as winders.

Finished floor below to finished floor above.

Measured on site with the finishes each floor will carry; the risers share it equally.

The rise per step you want.

The count of risers is the total rise over this, rounded up, so no riser is taller; the IRC allows a spiral stair 9 1/2 in, the NCC's spiral row 220 mm.

Across the stair from tread end to tread end.

Kits are sold by this figure. The opening above is at least this across.

The column a spiral stair turns on, or a helical stair's well.

The treads run from this circle to the outer one; the narrow end of each tread is here.

Degrees the walking treads turn through, first riser to the landing's front edge.

Shared over the treads, it sets each tread's angle: the more the stair turns, the deeper each tread and the more headroom one turn up.

The angle the top landing sweeps; 0 if the upper floor's edge is the last step.

A 90° landing is common on kits. It sits over the first treads one turn down, so a longer landing costs headroom there.

The tread's own thickness, for the headroom under it.

A tread on brackets or a stringer takes the depth of those as well; enter the whole depth to read headroom to its underside.

Measured along the outer edge.

Adds to each blank's sweep; 0 for treads that meet edge to edge.

Upper floor to the ceiling below it.

With the headroom, it sets how much of the circle the floor above must leave open.

Clear height over the treads under the floor above.

Opens on 6 ft 6 in (1981 mm), the IRC's spiral figure; the opening is worked for the figure entered.

One baluster's face.

Spaced on the outer edge so the gap stays inside the 4 in (100 mm) sphere.

Rails to develop and buy.

A helical stair's well usually takes an inner rail too.

Spares on what is cut to length or counted.

Treads are cut to one blank and take none.

The code the riser, going, width and headroom are read against.

Figures compared with the code's own, never compliance: the building official or building control body decides. Where this page does not read a code's figures it says so rather than guessing them.

Treads

13 treads

High confidence

WITHIN THE LIMITS CHECKED — clear width 692 mm (27.25 in), riser 196 mm (7.71 in), going 179 mm (7.06 in) at the walk line 12 in (305 mm) from the narrow edge, 2117 mm (83.36 in) of headroom one turn up, inside the figures this page reads for IRC R311.7.10.1. Limits checked, not an approval. Every tread here is the same blank, as R311.7.10.1 asks; the handrail's projection into the clear width is the maker's detail and is not taken off.

Risers
14 risers
Riser height
7.71 in · 7 11/16 in
Tread angle, nosing to nosing
27.69 °
Going at the code's measuring point
7.06 in · 7 1/16 in
Going at the narrow end
1.32 in · 1 5/16 in
Going at the outer edge
14.36 in · 14 3/8 in
Clear width, column to outer edge
27.25 in · 27 1/4 in
Least headroom one turn up
6.95 ft · 6 ft 11 3/8 in
Opening in the floor above, sweep
360 °
Outer handrail, developed
17.79 ft · 17 ft 9 1/2 in
Tread blank, area each
1.63 sq ft
Balusters on the outer edge
43 balusters
Then change the inputs to see how far the answer moves.

Show calculation logic

How this was calculated

Formula source(s)

  • US: IRC R311.7.10.1 (2018 and later), spiral stairways — clear width at and below the handrail at least 26 in, walk-line radius at most 24 1/2 in, each tread at least 6 3/4 in deep at the walk line, treads identical, rise at most 9 1/2 in, headroom at least 6 ft 6 in; R311.7.5.2.1 for a curved stair's treads (winders: 10 in at the walk line, 6 in at any point)
  • Australia: NCC 2022 Housing Provisions 11.2.2(4)(b) and Table 11.2.2a, spiral row — riser 140–220 mm, going 210–370 mm, 2R + G 590–680 mm, the going measured seven tenths of the unobstructed width out from the face of the centre pole
  • UK: Approved Document K (2013 edition), paragraph 1.28 — spiral and helical stairs designed in accordance with BS 5395-2
  • Developed helix length = sqrt((radius x rotation in radians)^2 + rise^2), the unrolled helix of this site's Spiral Stair Helix Geometry Calculator; a chord between two radial lines at radius r = 2 r sin(theta / 2)

Inputs used

Kind of stair
Spiral — treads round a centre column
Total Rise (floor to floor)
9 ft
Riser You Are Aiming For
8 in
Outer diameter (to the treads' outer edge)
5 ft
Inner diameter (column, or the open well)
5.5 in
Rotation of the treads (°)
360
Landing platform at the top (°)
60
Tread thickness
1.5 in
Overlap of each tread over the one below
1.25 in
Floor depth at the opening
9.75 in
Headroom to keep
78 in
Baluster width
1 in
Handrails
Outer edge
Curved string depth
10.75 in
Curved string thickness
1.75 in
Ply thickness, if laminated
0.25 in
Allowance on balusters and rails (%)
10
Code for the readout
US — IRC

Intermediate steps

Risers
14 risers
Riser height
7.71 in
Tread angle, nosing to nosing
27.69 °
Going at the code's measuring point
7.06 in
Going at the narrow end
1.32 in
Going at the outer edge
14.36 in
Clear width, column to outer edge
27.25 in
Least headroom one turn up
6.95 ft
Opening in the floor above, sweep
360 °
Outer handrail, developed
17.79 ft
Tread blank, area each
1.63 sq ft
Balusters on the outer edge
43 balusters
Final result13 treads

Confidence note: WITHIN THE LIMITS CHECKED — clear width 692 mm (27.25 in), riser 196 mm (7.71 in), going 179 mm (7.06 in) at the walk line 12 in (305 mm) from the narrow edge, 2117 mm (83.36 in) of headroom one turn up, inside the figures this page reads for IRC R311.7.10.1. Limits checked, not an approval. Every tread here is the same blank, as R311.7.10.1 asks; the handrail's projection into the clear width is the maker's detail and is not taken off.

What this calculation does not cover

  • This lays a spiral or helical stair out; it does not approve one. The width, riser, going and headroom it reads are your code's, checked by your building official, and a kit maker's own figures govern a kit.
  • The column, the treads' thickness, their brackets and the landing's fixing to the floor are the maker's or your engineer's: entered, never sized, and nothing here says they carry the stair.
  • Goings are chords between radial nosings; a tread cut with a curved or skewed nosing has other goings, and a kit's own drawing governs a kit.
  • Headroom one turn up is to the underside of the tread overhead as entered (its thickness); a stringer, a soffit or a bracket under it takes more, and the floor opening is worked for the headroom you enter, measured on site.
  • The rail lengths are developed helices at the outer edge and the inner line; a rail set in from the edge, its returns at the landing and the guard round the opening are not added.
  • A helical stair's curved strings are unrolled on the faces the treads are housed into, plumb-cut where they spring; the joints to the floor and the landing, the former they are bent on and whether their depth and thickness carry the stair are the maker's or your engineer's.

Estimated cost — your price

This site holds no price list for this material — local prices vary too much to publish honestly. Enter your supplier's price and the result is costed with it.

5 ft
Schematic, drawn to the proportions you entered — not to scale on screen.

Part of a bigger job

Or plan the space itself: measure it once, doors and windows included, and this figure comes back worked out on that space, with what goes with it.

Computed in your browser — nothing you enter is uploaded. Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.

Sources checked 2026-11-13 · 6 test vectors · v1.0.0

Regulatory standards & verification citations4
  1. US: IRC R311.7.10.1 (2018 and later), spiral stairways — clear width at and below the handrail at least 26 in, walk-line radius at most 24 1/2 in, each tread at least 6 3/4 in deep at the walk line, treads identical, rise at most 9 1/2 in, headroom at least 6 ft 6 in; R311.7.5.2.1 for a curved stair's treads (winders: 10 in at the walk line, 6 in at any point)
  2. Australia: NCC 2022 Housing Provisions 11.2.2(4)(b) and Table 11.2.2a, spiral row — riser 140–220 mm, going 210–370 mm, 2R + G 590–680 mm, the going measured seven tenths of the unobstructed width out from the face of the centre pole
  3. UK: Approved Document K (2013 edition), paragraph 1.28 — spiral and helical stairs designed in accordance with BS 5395-2
  4. Developed helix length = sqrt((radius x rotation in radians)^2 + rise^2), the unrolled helix of this site's Spiral Stair Helix Geometry Calculator; a chord between two radial lines at radius r = 2 r sin(theta / 2)

Which documents these citations point at

  • International Residential Code — R311.7.10.1 (United States)One- and two-family dwellings and townhouses up to three storeys — structure, fire safety, energy, plumbing, mechanical and electrical in a single document.
  • Approved Documents to the Building Regulations (England) — K (United Kingdom)Practical guidance on meeting the Building Regulations, one lettered part per subject — Part A structure, Part B fire, Part K protection from falling, Part L conservation of fuel and power, and the rest.

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments. This site holds no adoption data for any authority, so check what is in force with the authority where you build. Any section cited above without an edition should be checked against the edition in force where you build. What it would take to know.

Cite this page

Your workspace

Most jobs need more than one number. Add the calculators you need next and they open right here, underneath this one — your figures stay on screen and nothing is lost to a page change.

The stair drawn, set out and counted

A scaled elevation and plan of the stair, each tread numbered with the walk line and the landing, the going at your code's measuring point, the headroom one turn up, the opening above, the developed rails, and the parts, with the code readout.

Full-size tread template

Print one tread blank at full size — cut it, repeat it for every tread — with the overlap line, the walk line and the column's centre marked, or the landing platform, tiled over A4 or Letter with a calibration square on every sheet.

Every stair type, the planner and the templates: the Stairs hub

How to calculate spiral staircase (spiral, helical and curved stairs: treads, going, headroom and handrail) in 19 steps

  1. Kind of stairA column at the centre, or an open well.
  2. Total Rise (floor to floor)Finished floor below to finished floor above.
  3. Riser You Are Aiming ForThe rise per step you want.
  4. Outer diameter (to the treads' outer edge)Across the stair from tread end to tread end.
  5. Inner diameter (column, or the open well)The column a spiral stair turns on, or a helical stair's well.
  6. Rotation of the treads (°)Degrees the walking treads turn through, first riser to the landing's front edge.
  7. Landing platform at the top (°)The angle the top landing sweeps; 0 if the upper floor's edge is the last step.
  8. Tread thicknessThe tread's own thickness, for the headroom under it.
  9. Overlap of each tread over the one belowMeasured along the outer edge.
  10. Floor depth at the openingUpper floor to the ceiling below it.
  11. Headroom to keepClear height over the treads under the floor above.
  12. Baluster widthOne baluster's face.
  13. HandrailsRails to develop and buy.
  14. Curved string depthA helical stair's strings, square to their pitch.
  15. Curved string thicknessEach finished string's thickness.
  16. Ply thickness, if laminatedOne lamination, bent round a former.
  17. Allowance on balusters and rails (%)Spares on what is cut to length or counted.
  18. Code for the readoutThe code the riser, going, width and headroom are read against.
  19. TreadsThe tool computes the treads from those figures and shows the formula, its sources, and a confidence rating alongside it.

Treads by total rise (floor to floor)

Page defaults, not your figures above.

Total Rise (floor to floor)Treads (treads)
4 ft5
6 ft8
8 ft11
10 ft14
12 ft17
14 ft20
16 ft23

Frequently asked questions

How many steps does a spiral staircase need?
The total rise divided by the riser you aim for, rounded up, gives the risers; the treads are one fewer, because the landing or the upper floor is the last step. A 2.70 m storey at 210 mm is 13 risers and 12 treads.
Where is the going of a spiral stair measured?
Each code picks its own radius: the IRC at the walk line 12 in from the narrow edge, the NCC seven tenths of the width out from the column. This page gives the going at that radius for the code chosen, and at the narrow end and the outer edge.
Why does the landing cost headroom?
The landing sits one turn above the first treads. Over a tread three risers up, a 90° landing at the top of a 2.70 m stair leaves 2.66 m less those three risers; a shorter landing, or a stair that turns further before it, leaves more.
Preliminary estimate, not certified engineering. This tool produces an indicative quantity calculation for planning purposes only — it is not a certified structural analysis, a guaranteed material takeoff, or a substitute for building department approval. Always verify measurements on-site and have a licensed contractor or structural engineer review any load-bearing, code-sensitive, or safety-critical work before purchasing materials or starting construction. Spotted an arithmetic or standards error? Report it to contact@craftquantities.com with your inputs — a confirmed fix gets a permanent check of its own, so the same mistake cannot come back.