Materials & Quantities

Steel and Concrete L- and U-Shaped Stair Calculator (Landings, Channel or Zigzag Stringers, Waist and Bars)

A steel or cast stair turning on landings: flights, channel or zigzag stringers, tread plates and weight, or concrete, formwork and bars.

Risers: 15 risers for Total Rise 9 ft, Riser You Are Aiming For 7.25 in and Going 10.25 in, the page's opening figures; on the metric page, 2.8 m, 185 mm and 260 mm give 16 risers. Sources are cited below.

  • Answers as you type
  • 3 sources cited
  • Calculated in your browser
SettingsSettings for this calculationUS
Market
Imperial · sales tax
Who is doing the work?

Waste is set to 5% by hand. Pick a tier above to replace it, or keep your own figure.

Steel flights on stringers, or cast flights and slabs.

The flights and landings are split the same way for both.

Where the stair turns.

A quarter landing is the stair's width square; a half landing twice the width by once.

Finished floor below to finished floor above.

Measured on site with the finishes each floor will carry; the risers share it equally.

The rise per step you want.

Rounded up into whole risers, so none is taller, as the L- and U-shaped page counts them.

The same on every flight.

Your code sets the least it may be.

Width of the flights, and of the landings' sides.

A steel stair's treads span between the stringers' flanges.

Up to the first landing.

The rest go in the flight after it.

Straight sections, or a strip folded up the steps.

A zigzag stringer follows every riser and tread; its developed length and bends are counted.

Your section, never chosen or checked here.

Also frames the steel landings' edges.

Two at the sides; a third under a wide stair.

Your engineer's count.

Checker plate.

Weighed at 7850 kg/m³.

Tread past its riser.

Deepens each tread plate.

At each end, for the connection.

Added to each channel stringer's cut length.

Upper floor to the ceiling below.

Sets the opening with the headroom.

Clear height over the flights.

Opens on the IRC's 6 ft 8 in.

On the steel weight, the concrete and the bars.

Offcuts and over-pour.

The code the flights, landings and headroom are read against.

Figures compared with the code's own, never compliance: the building official or building control body decides. Where this page does not read a code's figures it says so rather than guessing them.

Risers

15 risers

High confidence

WITHIN THE LIMITS CHECKED — US IRC 2024: riser height 7.20 in (183 mm) and tread depth 10.25 in (260 mm) are inside the limits this calculator checks. That is not a compliance determination: headroom, handrails, guards, nosings and width are not checked, and the building control body or inspector decides. On this page, headroom is read on its own: the opening is worked out for 2032 mm (80.0 in) of headroom over the pitch line, at or above the 6 ft 8 in (2032 mm) of IRC 2024 R311.7.2; the headroom as built is measured on site. Each landing is 1067 mm (42.00 in) long in the direction of travel, at or over the 36 in (914 mm) of IRC R311.7.6.

Riser height
7.2 in · 7 3/16 in
Flights
2 flights
Landings
1 landing
Steel, all flights and landings, with the allowance
1,330.53 lb
Longest stringer as cut
8.33 ft · 8 ft 4 in
Tread plates
13 plates
Floor opening, plan area
46.82 sq ft
Then change the inputs to see how far the answer moves.

Show calculation logic

How this was calculated

Formula source(s)

  • Flights and landings split as this site's L- and U-shaped stair page splits them; each flight worked as its steel stair and concrete stair pages work one (sections from BS EN 10365 and the American standard channel tables, steel at 7850 kg/m³)
  • Zigzag stringer: a strip folded riser, tread, riser…, its developed length n x riser + (n - 1) x going and 2n - 1 bends; mass = length x strip depth x thickness x 7850 kg/m³
  • US: IRC R311.7.5 (riser at most 7 3/4 in, tread at least 10 in), R311.7.6 (landings at least 36 in in the direction of travel), R311.7.2 (headroom 6 ft 8 in); UK: Approved Document K section 1; Australia: NCC Housing Provisions 11.2.2 and 11.2.5; Canada: NBC 9.8.4 and 9.8.6, as the L- and U-shaped stair page reads them

Inputs used

Material
Steel stringers
Shape
L — a quarter landing
Total Rise (floor to floor)
9 ft
Riser You Are Aiming For
7.25 in
Going (nosing to nosing)
10.25 in
Stair width
3.5 ft
Risers in the first flight
8
Risers in the middle flight
3
Stringers (steel)
Rolled section (channel or flat)
Stringer section
PFC 200 × 75 (23.4 kg/m)
Stringers per flight
2
Zigzag strip depth
7.75 in
Zigzag plate thickness
0.31 in
Tread and landing plate thickness
0.25 in
Nosing
1 in
Stringer end allowance
4 in
Waist (concrete)
6 in
Landing slab thickness
6 in
Cover
1 in
Main bar diameter
0.5 in
Main bar spacing
6 in
Distribution bar diameter
0.39 in
Distribution bar spacing
9.75 in
Anchorage at each end
11.75 in
Floor depth at the opening
9.75 in
Headroom to keep
80 in
Allowance (%)
5
Code for the readout
US — IRC

Intermediate steps

Riser height
7.2 in
Flights
2 flights
Landings
1 landing
Steel, all flights and landings, with the allowance
1,330.53 lb
Longest stringer as cut
8.33 ft
Tread plates
13 plates
Floor opening, plan area
46.82 sq ft
Final result15 risers

Confidence note: WITHIN THE LIMITS CHECKED — US IRC 2024: riser height 7.20 in (183 mm) and tread depth 10.25 in (260 mm) are inside the limits this calculator checks. That is not a compliance determination: headroom, handrails, guards, nosings and width are not checked, and the building control body or inspector decides. On this page, headroom is read on its own: the opening is worked out for 2032 mm (80.0 in) of headroom over the pitch line, at or above the 6 ft 8 in (2032 mm) of IRC 2024 R311.7.2; the headroom as built is measured on site. Each landing is 1067 mm (42.00 in) long in the direction of travel, at or over the 36 in (914 mm) of IRC R311.7.6.

What this calculation does not cover

  • This counts and draws a steel or cast stair that turns; it does not approve it. The riser, going, landings and headroom are read against your code by the L- and U-shaped page's own readout; your building official decides.
  • Sections, plate and zigzag thicknesses, waists and bars are your engineer's: entered here, never chosen or checked, and nothing here says a member, a weld, a connection or a bar is adequate.
  • A zigzag stringer's length is its folded strip along its line; the bend allowance at each fold is the fabricator's, and the plate it is cut from is the strip's depth wide.
  • Landings are flat plates or slabs the stair's width square (a half landing twice the width by once); posts, hangers and the landing's bearing on walls are not counted.
3.5 ft
Schematic, drawn to the proportions you entered — not to scale on screen.

Computed in your browser — nothing you enter is uploaded. Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.

Sources checked 2026-11-14 · 9 test vectors · v1.0.0

Regulatory standards & verification citations3
  1. Flights and landings split as this site's L- and U-shaped stair page splits them; each flight worked as its steel stair and concrete stair pages work one (sections from BS EN 10365 and the American standard channel tables, steel at 7850 kg/m³)
  2. Zigzag stringer: a strip folded riser, tread, riser…, its developed length n x riser + (n - 1) x going and 2n - 1 bends; mass = length x strip depth x thickness x 7850 kg/m³
  3. US: IRC R311.7.5 (riser at most 7 3/4 in, tread at least 10 in), R311.7.6 (landings at least 36 in in the direction of travel), R311.7.2 (headroom 6 ft 8 in); UK: Approved Document K section 1; Australia: NCC Housing Provisions 11.2.2 and 11.2.5; Canada: NBC 9.8.4 and 9.8.6, as the L- and U-shaped stair page reads them

Which documents these citations point at

  • International Residential Code — R311.7.5 (United States)One- and two-family dwellings and townhouses up to three storeys — structure, fire safety, energy, plumbing, mechanical and electrical in a single document.
  • Approved Documents to the Building Regulations (England) — K (United Kingdom)Practical guidance on meeting the Building Regulations, one lettered part per subject — Part A structure, Part B fire, Part K protection from falling, Part L conservation of fuel and power, and the rest.

Standards referenced: BS EN 10365 (European Committee for Standardization, as published in the UK by BSI, European (EN)).

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments. This site holds no adoption data for any authority, so check what is in force with the authority where you build. Any section cited above without an edition should be checked against the edition in force where you build. What it would take to know.

Cite this page

Your workspace

Most jobs need more than one number. Add the calculators you need next and they open right here, underneath this one — your figures stay on screen and nothing is lost to a page change.

Tools and safety for this job

To place and finish concrete, erect formwork and saw-cut cured concrete. Generic types, no brands, no prices.

Protection this work requires

  • Cutting or grinding concrete, masonry, screed, tile or fibre-cement board releases respirable silica: cut wet or extract at the tool, and wear a P2/N95 respirator at minimum — a nuisance dust mask does not filter it.
  • Hardwood dust is a recognised carcinogen: extract at the tool and wear a P2/N95 respirator when cutting or sanding indoors.
  • Wet cement and lime burn skin and eyes painlessly until the damage is done: waterproof gloves to EN 374, safety glasses whenever the mix can splash, and never kneel in wet mix in permeable trousers.
  • Saws, grinders and breakers run above 85 dB, where hearing damage accumulates and does not recover: defenders or plugs for every cut, not just the long ones.
  • Breakers and grinders cause permanent nerve damage: limit continuous trigger time, keep hands warm, and stop if fingers tingle or blanch.
  • Boards, blocks and bagged material cause most lasting back injuries on small sites: two people or a lifter for full sheets, and never a bag on one shoulder up a ladder.
Show the 17 tools this job needs

Essential

  • Angle grinder

  • Bull float and edger

  • Circular saw

  • Claw hammer

  • Dust extractor or vacuum with a fine filter

  • Screed bar or rail

  • Shovel and spade

  • Spirit level

  • String line and pins

  • Tape measure

  • Wheelbarrow

Recommended

  • Chalk line

  • Cordless drill/driver

  • Floor or cut-off saw

  • Plate compactor

  • SDS rotary hammer

Optional

  • Power float

Also needed as materials: chalk refill, circular saw blades, cutting and diamond discs, diamond blades, drill and driver bits, SDS bits and chisels.

what each concrete tool is for, and the spec that decides which to buy where one does.

The stair drawn, its flights and landings listed

A scaled plan and unfolded elevation of the flights and landings, the opening above, and each flight's stringers or cast section with each landing's plate or slab, by weight or volume and bars, with the code readout.

The data behind it: Bulk densities of construction materials

Every stair type, the planner and the templates: the Stairs hub

How to calculate steel and concrete L- and U-shaped stair (landings, channel or zigzag stringers, waist and bars) in 29 steps

  1. MaterialSteel flights on stringers, or cast flights and slabs.
  2. ShapeWhere the stair turns.
  3. Total Rise (floor to floor)Finished floor below to finished floor above.
  4. Riser You Are Aiming ForThe rise per step you want.
  5. Going (nosing to nosing)The same on every flight.
  6. Stair widthWidth of the flights, and of the landings' sides.
  7. Risers in the first flightUp to the first landing.
  8. Risers in the middle flightBetween the two quarter landings.
  9. Stringers (steel)Straight sections, or a strip folded up the steps.
  10. Stringer sectionYour section, never chosen or checked here.
  11. Stringers per flightTwo at the sides; a third under a wide stair.
  12. Zigzag strip depthWidth of the folded strip.
  13. Zigzag plate thicknessThe plate's thickness.
  14. Tread and landing plate thicknessChecker plate.
  15. NosingTread past its riser.
  16. Stringer end allowanceAt each end, for the connection.
  17. Waist (concrete)Square to the soffit.
  18. Landing slab thicknessThe landings' slab.
  19. CoverTo the bars.
  20. Main bar diameterAlong each flight and both ways in the landings.
  21. Main bar spacingCentre to centre, along the flights and both ways in the landings.
  22. Distribution bar diameterAcross each flight.
  23. Distribution bar spacingCentre to centre, across each flight.
  24. Anchorage at each endMain bars carried into the floor or landing.
  25. Floor depth at the openingUpper floor to the ceiling below.
  26. Headroom to keepClear height over the flights.
  27. Allowance (%)On the steel weight, the concrete and the bars.
  28. Code for the readoutThe code the flights, landings and headroom are read against.
  29. RisersThe tool computes the risers from those figures and shows the formula, its sources, and a confidence rating alongside it.

Risers by total rise (floor to floor)

Page defaults, not your figures above.

Total Rise (floor to floor)Risers (risers)
4 ft0
6 ft10
8 ft14
10 ft17
12 ft20
14 ft24
16 ft27

Frequently asked questions

How long is a zigzag stair stringer?
Along its line, every riser and every tread it folds round: n risers and n - 1 goings. Sixteen risers split 8 and 8 at 175 mm on a 260 mm going make each flight's strip 8 x 0.175 + 7 x 0.26 = 3.22 m with 15 bends.
How much does a steel L-shaped stair weigh?
Add each flight's stringers, tread plates and brackets to the landing's plate and its frame. A 1 m wide, 2.80 m stair on PFC 200 channels with 6 mm plates comes to about 117 kg of channel and 80 kg of plate a flight, and 141 kg for the landing, before brackets and the allowance.
Can it work out a cast concrete U-shaped stair?
Yes: each flight is the cast flight page's section at its own rise, and each landing a slab of your thickness with bars both ways, so the concrete, the formwork and the bars come out for the whole stair.
Preliminary estimate, not certified engineering. This tool produces an indicative quantity calculation for planning purposes only — it is not a certified structural analysis, a guaranteed material takeoff, or a substitute for building department approval. Always verify measurements on-site and have a licensed contractor or structural engineer review any load-bearing, code-sensitive, or safety-critical work before purchasing materials or starting construction. Spotted an arithmetic or standards error? Report it to contact@craftquantities.com with your inputs — a confirmed fix gets a permanent check of its own, so the same mistake cannot come back.