SettingsSettings for this calculationUS
Waste is set to 5% by hand. Pick a tier above to replace it, or keep your own figure.
Finished level to finished level.
The risers share it equally; the steel is cut to the slope it makes over the run.
The rise is divided into the whole number of risers nearest this.
The stair rise and run page's division.
Front of one tread to the front of the next, on plan.
Also each bracket's length.
Outside to outside of the two outer stringers.
The treads span between the stringers' webs, so each tread is this less the two flanges.
The rolled section your drawing calls for.
Chosen by you or your engineer; its mass per length is the section tables'. Nothing here checks that it spans.
Two at the sides, and any under the middle.
Each is the same cut length.
Extra length at the top and the bottom for the connection.
Added to both ends of every stringer; the cut detail is the fabricator's.
Plate is weighed here; grating is counted by the piece.
A grating tread's weight is its maker's.
The checker plate's thickness.
Its weight is its area times this times 7850 kg/m³ (490 lb/ft³).
How far each tread runs past the one below.
Added to the going for the tread's depth.
The length the section is bought in.
The page counts how many stringers each length gives whole.
Offcuts and cleats, as a percentage of the steel.
Added to the weight; the counts are as cut.
The limits the riser and the going are read against.
Limits checked, not compliance.
Steel in the flight, with the allowance
1,003 lb
WITHIN THE LIMITS CHECKED — US IRC 2024: riser height 7.20 in (183 mm) and tread depth 10.25 in (260 mm) are inside the limits this calculator checks. That is not a compliance determination: headroom, handrails, guards, nosings and width are not checked, and the building control body or inspector decides. The section and the fixings are the ones you chose; nothing here says they are adequate.
- Risers
- 15 risers
- Rise of each step
- 7.2 in · 7 3/16 in
- Treads
- 14 treads
- Pitch
- 35.09 °
- Stringer cut length, each
- 15.63 ft · 15 ft 7 5/8 in
- Stock lengths for the stringers
- 2 lengths
- Steel in the stringers
- 491.64 lb
- Tread length between the stringers
- 3.01 ft · 3 ft 0 1/8 in
- Steel in the tread plates
- 403.06 lb
- Brackets
- 28 angles
- Steel in the brackets
- 60.59 lb
- Bolts
- 112 bolts
- Steel as cut
- 955.29 lb
They open the calculator with your figures already in it
Steel Stair Calculator (Stringer Cut List, Tread Plates and Weight): 1,003 lb — shown in imperial, US market. The link sets both, so the result they see is the one on your screen.
Show calculation logicHide calculation logic
How this was calculated
Formula source(s)
- A stringer along the flight's slope, sqrt(rise² + run²), the steel stair stringer length page's geometry, plus the connection allowance at each end
- Section masses: parallel flange channels to BS EN 10365 as the UK steel makers' section tables print them (PFC 180 x 75 20.3 kg/m, 200 x 75 23.4, 230 x 75 25.7, 260 x 75 27.6); American Standard channels C8 x 11.5, C10 x 15.3 and C12 x 20.7, whose designation gives the weight in lb/ft (AISC Shapes Database); flats and plates at 7850 kg/m³; equal angle L50 x 50 x 5 at 3.77 kg/m (BS EN 10056-1)
- US: IRC 2024 R311.7.5; UK: Approved Document K Table 1.1; Australia: NCC Housing Provisions Table 11.2.2a; Canada: NBC 2020 Tables 9.8.4.1 and 9.8.4.2, as the stair rise and run page checks them
Inputs used
- Floor-to-floor rise
- 9 ft
- Riser to aim for
- 7.25 in
- Going
- 10.25 in
- Width over the stringers
- 3.5 ft
- Stringer section
- PFC 200 × 75 (23.4 kg/m)
- Stringers
- 2
- Allowance at each end
- 4 in
- Treads
- Checker plate
- Plate thickness
- 0.25 in
- Tread overhang
- 1 in
- Stock length of the section
- 20 ft
- Allowance on the weight
- 5
- Code for the readout
- US — IRC 2024
Intermediate steps
- Risers
- 15 risers
- Rise of each step
- 7.2 in
- Treads
- 14 treads
- Pitch
- 35.09 °
- Stringer cut length, each
- 15.63 ft
- Stock lengths for the stringers
- 2 lengths
- Steel in the stringers
- 491.64 lb
- Tread length between the stringers
- 3.01 ft
- Steel in the tread plates
- 403.06 lb
- Brackets
- 28 angles
- Steel in the brackets
- 60.59 lb
- Bolts
- 112 bolts
- Steel as cut
- 955.29 lb
Confidence note: WITHIN THE LIMITS CHECKED — US IRC 2024: riser height 7.20 in (183 mm) and tread depth 10.25 in (260 mm) are inside the limits this calculator checks. That is not a compliance determination: headroom, handrails, guards, nosings and width are not checked, and the building control body or inspector decides. The section and the fixings are the ones you chose; nothing here says they are adequate.
What this calculation does not cover
- The section, the plate and the fixings are yours or your engineer's: this counts and weighs what you choose and never says the stringer spans, the tread carries its load or the connections hold.
- One straight flight between two levels, with each stringer cut to the slope plus the allowance you enter at each end for its connection; the end plates, the cleats, the welds and the landing's steel are not counted.
- Treads are counted as one plate or grating a step between the outer stringers' flanges, carried on two angle brackets each, bolted twice to the stringer and twice to the tread. Grating is counted by the piece; its own weight is the supplier's.
- Weights are of bare steel. Galvanising adds to them, and paint or galvanising areas are not worked out here.
Estimated cost — your price
This site holds no price list for this material — local prices vary too much to publish honestly. Enter your supplier's price and the result is costed with it.
Part of a bigger job
This trade is one line of a job takeoff. Run the whole job and every other trade comes back with it, off the same measurements.
Computed in your browser — nothing you enter is uploaded. Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.
Sources checked 2026-10-31 · 10 test vectors · v1.0.1
Regulatory standards & verification citations3
- A stringer along the flight's slope, sqrt(rise² + run²), the steel stair stringer length page's geometry, plus the connection allowance at each end
- Section masses: parallel flange channels to BS EN 10365 as the UK steel makers' section tables print them (PFC 180 x 75 20.3 kg/m, 200 x 75 23.4, 230 x 75 25.7, 260 x 75 27.6); American Standard channels C8 x 11.5, C10 x 15.3 and C12 x 20.7, whose designation gives the weight in lb/ft (AISC Shapes Database); flats and plates at 7850 kg/m³; equal angle L50 x 50 x 5 at 3.77 kg/m (BS EN 10056-1)
- US: IRC 2024 R311.7.5; UK: Approved Document K Table 1.1; Australia: NCC Housing Provisions Table 11.2.2a; Canada: NBC 2020 Tables 9.8.4.1 and 9.8.4.2, as the stair rise and run page checks them
Which documents these citations point at
- International Residential Code — 2024 R311.7.5 (United States)One- and two-family dwellings and townhouses up to three storeys — structure, fire safety, energy, plumbing, mechanical and electrical in a single document.
- Approved Documents to the Building Regulations (England) — K (United Kingdom)Practical guidance on meeting the Building Regulations, one lettered part per subject — Part A structure, Part B fire, Part K protection from falling, Part L conservation of fuel and power, and the rest.
Standards referenced: BS EN 10365, BS EN 10056-1 (European Committee for Standardization, as published in the UK by BSI, European (EN)).
A code or standard has force only where a jurisdiction has adopted it, usually with local amendments. This site holds no adoption data for any authority, so check what is in force with the authority where you build. Any section cited above without an edition should be checked against the edition in force where you build. What it would take to know.
Cite this page
Your workspace
Most jobs need more than one number. Add the calculators you need next and they open right here, underneath this one — your figures stay on screen and nothing is lost to a page change.
Tools and safety for this job
To fit the staircase. Generic types, no brands, no prices.
Protection this work requires
- Hardwood dust is a recognised carcinogen: extract at the tool and wear a P2/N95 respirator when cutting or sanding indoors.
- Boards, blocks and bagged material cause most lasting back injuries on small sites: two people or a lifter for full sheets, and never a bag on one shoulder up a ladder.
- Most fatal falls on small jobs are from under three metres: use a tower or a ladder tied at the top, and never work off the top two rungs.
Fit the staircase: Fitting a flight is joinery. Its rise, going (run), pitch, headroom and guarding are set by the building regulations or code the work falls under, and this site flags a geometry that falls outside them rather than approving any stair.
Show the 5 tools this job needsHide tools
Essential
Hand saw
Impact driver
Spirit level
Tape measure
Recommended
Combination or framing square
Also needed as materials: impact driver bits.
what each carpentry tool is for, and the spec that decides which to buy where one does.
The steel flight drawn and listed
A scaled elevation and plan of the stringers and treads, and the cut list: each stringer's length and stock, the tread plates, brackets and bolts, and the weight, with the code readout.