Materials & Quantities

Fire-Rated Shaftwall Liner Panel Count Calculator

Calculate how many shaftwall liner panels are needed to fill the stud cavities of a shaft wall assembly.

  • Answers as you type
  • Every formula cited
  • Calculated in your browser
SettingsSettings for this calculationUS
Market
Imperial · sales tax
The total length of the shaft wall run.

Measure the full horizontal run of the shaftwall assembly along the floor track.

The width of one shaftwall liner panel.

Shaftwall liner panels are commonly 24 in (about 0.61 m) wide and 1 in thick, sized to friction-fit between the CH studs — check your specific manufacturer's panel width.

Liner panels needed

17 panels

High confidence
Then change the inputs to see how far the answer moves.

Show calculation logic

How this was calculated

Formula source(s)

  • Liner panel count = ceil(wall length ÷ liner panel width) — shaftwall liner panels are commonly 1 in thick and 24 in wide, friction-fit between the shaftwall studs

Inputs used

Wall Length
33 ft
Liner Panel Width
2 ft
Final result17 panels

What this calculation does not cover

  • Stud spacing is not an input, so the panel width is assumed to be the stud module — but a friction-fit liner only works when the two are the same. If the assembly listing calls for C-H studs at 406 mm (16 in) centres while the panel stays 610 mm (24 in) wide, a 10 m run has 25 bays to fill and this returns 17, because it counts panel widths along the wall rather than bays between studs.
  • Wall height is not an input, so the result assumes one panel per bay running floor to soffit in a single piece. Shaft liner is supplied in fixed lengths that stop well short of a tall storey — a 16 ft (about 4.9 m) maximum is common, and it varies by manufacturer — and a storey deeper than that needs panels stacked in the bay with an H-stud or a fire-stopped end joint at every splice, which multiplies the count per bay and adds a detail this number knows nothing about.
  • The length is treated as one straight, continuous run, so the rounding up happens once for the whole figure instead of once at each corner. Four 2.5 m shaft faces are 5 panels each and 20 in total, while entering their 10 m combined length returns 17. The input also stops at 60 m, so a long run or a whole shaft perimeter has to be split and each face counted on its own.
  • Nothing in the result responds to the fire rating being sought — a one-hour and a two-hour shaft of the same length return the same liner count. The rating is carried by the tested assembly as a whole: the stud section, the liner thickness, the number and orientation of finish-side gypsum layers, and the joint treatment. A correct panel count assembled outside that listing is not a rated wall.
  • The last panel is counted whole even when only a 100 mm strip is wanted, and the offcut is assumed to be scrap rather than carried to the next bay. No waste percentage, breakage allowance or spare panels are added on top, which matters for a 25 mm liner board that is slid in edgewise and damages easily at the edge, so runs with several returns or openings need an allowance set separately.
  • The count covers the liner only. C-H studs, J-runners and floor and head track, the finish-side board layers, fasteners, tape and the head-of-wall deflection detail are all outside it, as is any check that the assembly can carry the shaft pressure it will see in service.

Estimated cost — your price

This site holds no price list for this material — local prices vary too much to publish honestly. Enter your supplier's price and the result is costed with it.

10 ft2 m33 ft10.06 m2 ft0.61 m

Computed in your browser — nothing you enter is uploaded. Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.

Sources checked 2026-09-02 · in the site-wide review of 2026-09-06 · v1.0.1

Regulatory standards & verification citations1
  1. Liner panel count = ceil(wall length ÷ liner panel width) — shaftwall liner panels are commonly 1 in thick and 24 in wide, friction-fit between the shaftwall studs
Cite this page

Your workspace

Most jobs need more than one number. Add the calculators you need next and they open right here, underneath this one — your figures stay on screen and nothing is lost to a page change.

Now that you have the number

These guides cover the work this quantity is for — the first ones run this calculator inside the section that raises the question.

Still deciding? Shaftwall vs Conventional Fire-Rated Partition — the factors that actually differ, with no invented prices.

How to calculate fire-rated shaftwall liner panel count in 3 steps

  1. Wall LengthThe total length of the shaft wall run.
  2. Liner Panel WidthThe width of one shaftwall liner panel.
  3. Liner panels neededThe tool computes the liner panels needed from those figures and shows the formula, its sources, and a confidence rating alongside it.

Liner panels needed by wall length

Page defaults, not your figures above.

Wall LengthLiner panels needed (panels)
20 ft10
30 ft15
40 ft20
50 ft25
60 ft30

Frequently asked questions

Why is this panel installed from outside the shaft?
Because there is nowhere to stand inside one. A lift shaft or a service riser is an open drop for the height of the building, and the entire point of the shaftwall system is that it can be erected from the floor side: the liner panel slides edgewise into the C-H studs already standing, and the operative never enters the shaft or works off a platform inside it. That constraint shapes the product — the panels are typically 25 mm gypsum in a moisture-resistant core, sized to slide rather than to be screwed through, and their edges are what carry the fire rating at the joint. It is a safety-of-construction decision expressed as a board, which is why the quantity is counted by panel and by shaft height rather than by wall area.
Why are liner panels sized by wall length, not area?
Shaftwall liner panels stand vertically, friction-fit between adjacent CH studs to span the full height of the wall in one piece — so the quantity needed depends on how many panel widths fit along the wall's length, not the wall's total area.
How wide and thick is a standard shaftwall liner panel?
Shaftwall liner panels are commonly 1 in thick and 24 in (about 0.61 m) wide, but always confirm the exact width from your specific manufacturer's product data before finalizing a takeoff.
Does this account for door or louver openings in the shaft wall?
No — this calculates the base liner panel count for a continuous wall length only. Openings for doors, louvers, or access panels should be deducted from your layout separately.
Preliminary estimate, not certified engineering. This tool produces an indicative quantity calculation for planning purposes only — it is not a certified structural analysis, a guaranteed material takeoff, or a substitute for building department approval. Always verify measurements on-site and have a licensed contractor or structural engineer review any load-bearing, code-sensitive, or safety-critical work before purchasing materials or starting construction. Spotted an arithmetic or standards error? Report it to contact@craftquantities.com with your inputs — a confirmed fix gets a permanent check of its own, so the same mistake cannot come back.