Materials & Quantities

Split (Bifurcated) Stair Calculator (Imperial Staircase: Flights, Landing, Stringers and Treads)

A split stair from your rise and widths: the first flight, the half landing and two return flights, with stringers, treads, rails and the plan.

Risers: 18 risers for Total Rise 10 ft, Riser You Are Aiming For 7 in and Going 11 in, the page's opening figures; on the metric page, 3 m, 180 mm and 280 mm give 17 risers. Sources are cited below.

  • Answers as you type
  • 3 sources cited
  • Calculated in your browser
SettingsSettings for this calculationUS
Market
Imperial · sales tax
Who is doing the work?

The standard allowance most suppliers and estimating guides assume for ordinary work.

Finished floor below to finished floor above.

Measured on site with the finishes each floor will carry; the risers share it equally.

The rise per step you want.

Rounded up into whole risers, so none is taller.

The same on every flight.

Your code sets the least it may be.

Up to the half landing.

The two return flights share the rest, each the same.

The wide flight up the middle.

Often near twice a return flight.

Each of the two flights back up.

Both the same.

Between the first flight and each return.

A wall, a guard or a well.

In the direction of travel.

Read against each code's landing rule.

Tread past its riser.

Moves the top nosing out, where the opening is measured from.

On each notch.

Cuts each first riser short by it.

Your board, never recommended.

Sets the throat.

Your count.

A wide flight takes more.

Your count.

The same under both.

Upper floor to the ceiling below.

Sets the openings with the headroom.

Clear height over the flights.

Opens on the IRC's 6 ft 8 in.

Each board gives as many treads as fit whole.

The first flight's and the returns' treads are counted on their own widths.

On treads, risers and rail.

Stringers are whole members.

The code the risers, going, landing and headroom are read against.

Figures compared with the code's own, never compliance: the building official or building control body decides. Where this page does not read a code's figures it says so rather than guessing them.

Risers

18 risers

High confidence

WITHIN THE LIMITS CHECKED — US IRC 2024: riser height 6.67 in (169 mm) and tread depth 11.00 in (279 mm) are inside the limits this calculator checks. That is not a compliance determination: headroom, handrails, guards, nosings and width are not checked, and the building control body or inspector decides. On this page, headroom is read on its own: the opening is worked out for 2032 mm (80.0 in) of headroom over the pitch line, at or above the 6 ft 8 in (2032 mm) of IRC 2024 R311.7.2; the headroom as built is measured on site. The landing is 1524 mm (60.0 in) deep, at or over the stair's width and at least 36 in (914 mm) (IRC R311.7.6).

Riser height
6.67 in · 6 11/16 in
Risers in each return flight
9 risers
Landing height
5 ft
Stair width on plan
12.67 ft · 12 ft 8 in
Stair depth on plan
12.33 ft · 12 ft 4 in
First flight's stringer board
8.52 ft · 8 ft 6 1/4 in
Return flights' stringer board
8.52 ft · 8 ft 6 1/4 in
Treads in all
24 treads
Handrail, total with the allowance
58.58 ft · 58 ft 6 15/16 in
Open over each return flight
7.33 ft · 7 ft 4 in
Then change the inputs to see how far the answer moves.

Show calculation logic

How this was calculated

Formula source(s)

  • Risers shared equally over the total rise (this site's stair rise and run rule, rounded up); each flight's stringer from this site's full-size stringer template
  • US: IRC R311.7.5 and R311.7.6 (risers, treads, landings at least the stair's width and 36 in deep); UK: Approved Document K section 1 (landings at least the width of the flight); Australia: NCC Housing Provisions 11.2.5(1)(a) (landings at least 750 mm); Canada: NBC 9.8.6.3.(1)
  • The opening over each return flight = nosing + (headroom + floor depth) x going / riser, as this site's stair stringer page works it

Inputs used

Total Rise (floor to floor)
10 ft
Riser You Are Aiming For
7 in
Going (nosing to nosing)
11 in
Risers in the first flight
9
First flight width
5 ft
Return flight width
3.5 ft
Gap beside the first flight
4 in
Landing depth
5 ft
Nosing
1 in
Tread thickness
1.25 in
Stringer board depth
11.25 in
Stringers under the first flight
3
Stringers under each return flight
2
Floor depth at the opening
11.75 in
Headroom to keep
80 in
Tread board length
12 ft
Allowance (%)
10
Code for the readout
US — IRC

Intermediate steps

Riser height
6.67 in
Risers in each return flight
9 risers
Landing height
5 ft
Stair width on plan
12.67 ft
Stair depth on plan
12.33 ft
First flight's stringer board
8.52 ft
Return flights' stringer board
8.52 ft
Treads in all
24 treads
Handrail, total with the allowance
58.58 ft
Open over each return flight
7.33 ft
Final result18 risers

Confidence note: WITHIN THE LIMITS CHECKED — US IRC 2024: riser height 6.67 in (169 mm) and tread depth 11.00 in (279 mm) are inside the limits this calculator checks. That is not a compliance determination: headroom, handrails, guards, nosings and width are not checked, and the building control body or inspector decides. On this page, headroom is read on its own: the opening is worked out for 2032 mm (80.0 in) of headroom over the pitch line, at or above the 6 ft 8 in (2032 mm) of IRC 2024 R311.7.2; the headroom as built is measured on site. The landing is 1524 mm (60.0 in) deep, at or over the stair's width and at least 36 in (914 mm) (IRC R311.7.6).

What this calculation does not cover

  • This lays a split stair out; it does not approve it. The riser, going, landing and headroom are read against your code; the widths a split stair's flights must keep for the people it serves (its occupancy) are your building official's call.
  • The stringers' depth and count, the landing's framing and its posts are your engineer's or the stair maker's: entered or left out, never sized here.
  • The return flights are drawn the same width and straight; a split stair whose returns curve, or whose first flight widens at its foot, is set out by the maker.
5 ft
Schematic, drawn to the proportions you entered — not to scale on screen.

Computed in your browser — nothing you enter is uploaded. Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.

Sources checked 2026-11-14 · 5 test vectors · v1.0.0

Regulatory standards & verification citations3
  1. Risers shared equally over the total rise (this site's stair rise and run rule, rounded up); each flight's stringer from this site's full-size stringer template
  2. US: IRC R311.7.5 and R311.7.6 (risers, treads, landings at least the stair's width and 36 in deep); UK: Approved Document K section 1 (landings at least the width of the flight); Australia: NCC Housing Provisions 11.2.5(1)(a) (landings at least 750 mm); Canada: NBC 9.8.6.3.(1)
  3. The opening over each return flight = nosing + (headroom + floor depth) x going / riser, as this site's stair stringer page works it

Which documents these citations point at

  • International Residential Code — R311.7.5 (United States)One- and two-family dwellings and townhouses up to three storeys — structure, fire safety, energy, plumbing, mechanical and electrical in a single document.
  • Approved Documents to the Building Regulations (England) — K (United Kingdom)Practical guidance on meeting the Building Regulations, one lettered part per subject — Part A structure, Part B fire, Part K protection from falling, Part L conservation of fuel and power, and the rest.

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments. This site holds no adoption data for any authority, so check what is in force with the authority where you build. Any section cited above without an edition should be checked against the edition in force where you build. What it would take to know.

Cite this page

Your workspace

Most jobs need more than one number. Add the calculators you need next and they open right here, underneath this one — your figures stay on screen and nothing is lost to a page change.

The split stair drawn and counted

A scaled plan of the first flight, the landing across the whole stair and the two return flights, with the risers, stringers, treads, risers and rails, the openings above and the code readout.

Full-size stringer templates

Print the first flight's stringer and the return flights' stringer at full size, each with every notch, its foot and its head, or the one-notch step gauge both flights repeat, tiled over A4 or Letter with a calibration square and cross-hairs to line the sheets up.

Every stair type, the planner and the templates: the Stairs hub

How to calculate split (bifurcated) stair (imperial staircase: flights, landing, stringers and treads) in 19 steps

  1. Total Rise (floor to floor)Finished floor below to finished floor above.
  2. Riser You Are Aiming ForThe rise per step you want.
  3. Going (nosing to nosing)The same on every flight.
  4. Risers in the first flightUp to the half landing.
  5. First flight widthThe wide flight up the middle.
  6. Return flight widthEach of the two flights back up.
  7. Gap beside the first flightBetween the first flight and each return.
  8. Landing depthIn the direction of travel.
  9. NosingTread past its riser.
  10. Tread thicknessOn each notch.
  11. Stringer board depthYour board, never recommended.
  12. Stringers under the first flightYour count.
  13. Stringers under each return flightYour count.
  14. Floor depth at the openingUpper floor to the ceiling below.
  15. Headroom to keepClear height over the flights.
  16. Tread board lengthEach board gives as many treads as fit whole.
  17. Allowance (%)On treads, risers and rail.
  18. Code for the readoutThe code the risers, going, landing and headroom are read against.
  19. RisersThe tool computes the risers from those figures and shows the formula, its sources, and a confidence rating alongside it.

Frequently asked questions

What is a bifurcated stair?
A split or imperial stair: one wide flight rises to a half landing and two narrower flights turn back up on either side of it to the floor above.
How are the risers split?
All risers are the same height. The first flight takes the count you enter and the two return flights share the rest equally: 17 risers of 176 mm split 9 up the middle and 8 up each side.
How big is the landing?
As wide as the whole stair, the first flight plus both gaps and both returns, and as deep as you enter; each code's landing rule is read against that depth.
Preliminary estimate, not certified engineering. This tool produces an indicative quantity calculation for planning purposes only — it is not a certified structural analysis, a guaranteed material takeoff, or a substitute for building department approval. Always verify measurements on-site and have a licensed contractor or structural engineer review any load-bearing, code-sensitive, or safety-critical work before purchasing materials or starting construction. Spotted an arithmetic or standards error? Report it to contact@craftquantities.com with your inputs — a confirmed fix gets a permanent check of its own, so the same mistake cannot come back.