SettingsSettings for this calculationUS
The standard allowance most suppliers and estimating guides assume for ordinary work.
Finished floor below to finished floor above.
Measured on site with the finishes each floor will carry; the risers share it equally.
The rise per step you want.
Rounded up into whole risers, so none is taller.
The same on every flight.
Your code sets the least it may be.
Up to the half landing.
The two return flights share the rest, each the same.
The wide flight up the middle.
Often near twice a return flight.
Each of the two flights back up.
Both the same.
Between the first flight and each return.
A wall, a guard or a well.
In the direction of travel.
Read against each code's landing rule.
Tread past its riser.
Moves the top nosing out, where the opening is measured from.
On each notch.
Cuts each first riser short by it.
Your board, never recommended.
Sets the throat.
Your count.
A wide flight takes more.
Your count.
The same under both.
Upper floor to the ceiling below.
Sets the openings with the headroom.
Clear height over the flights.
Opens on the IRC's 6 ft 8 in.
Each board gives as many treads as fit whole.
The first flight's and the returns' treads are counted on their own widths.
On treads, risers and rail.
Stringers are whole members.
The code the risers, going, landing and headroom are read against.
Figures compared with the code's own, never compliance: the building official or building control body decides. Where this page does not read a code's figures it says so rather than guessing them.
Risers
18 risers
WITHIN THE LIMITS CHECKED — US IRC 2024: riser height 6.67 in (169 mm) and tread depth 11.00 in (279 mm) are inside the limits this calculator checks. That is not a compliance determination: headroom, handrails, guards, nosings and width are not checked, and the building control body or inspector decides. On this page, headroom is read on its own: the opening is worked out for 2032 mm (80.0 in) of headroom over the pitch line, at or above the 6 ft 8 in (2032 mm) of IRC 2024 R311.7.2; the headroom as built is measured on site. The landing is 1524 mm (60.0 in) deep, at or over the stair's width and at least 36 in (914 mm) (IRC R311.7.6).
- Riser height
- 6.67 in · 6 11/16 in
- Risers in each return flight
- 9 risers
- Landing height
- 5 ft
- Stair width on plan
- 12.67 ft · 12 ft 8 in
- Stair depth on plan
- 12.33 ft · 12 ft 4 in
- First flight's stringer board
- 8.52 ft · 8 ft 6 1/4 in
- Return flights' stringer board
- 8.52 ft · 8 ft 6 1/4 in
- Treads in all
- 24 treads
- Handrail, total with the allowance
- 58.58 ft · 58 ft 6 15/16 in
- Open over each return flight
- 7.33 ft · 7 ft 4 in
They open the calculator with your figures already in it
Split (Bifurcated) Stair Calculator (Imperial Staircase: Flights, Landing, Stringers and Treads): 18 risers — shown in imperial, US market. The link sets both, so the result they see is the one on your screen.
Show calculation logicHide calculation logic
How this was calculated
Formula source(s)
- Risers shared equally over the total rise (this site's stair rise and run rule, rounded up); each flight's stringer from this site's full-size stringer template
- US: IRC R311.7.5 and R311.7.6 (risers, treads, landings at least the stair's width and 36 in deep); UK: Approved Document K section 1 (landings at least the width of the flight); Australia: NCC Housing Provisions 11.2.5(1)(a) (landings at least 750 mm); Canada: NBC 9.8.6.3.(1)
- The opening over each return flight = nosing + (headroom + floor depth) x going / riser, as this site's stair stringer page works it
Inputs used
- Total Rise (floor to floor)
- 10 ft
- Riser You Are Aiming For
- 7 in
- Going (nosing to nosing)
- 11 in
- Risers in the first flight
- 9
- First flight width
- 5 ft
- Return flight width
- 3.5 ft
- Gap beside the first flight
- 4 in
- Landing depth
- 5 ft
- Nosing
- 1 in
- Tread thickness
- 1.25 in
- Stringer board depth
- 11.25 in
- Stringers under the first flight
- 3
- Stringers under each return flight
- 2
- Floor depth at the opening
- 11.75 in
- Headroom to keep
- 80 in
- Tread board length
- 12 ft
- Allowance (%)
- 10
- Code for the readout
- US — IRC
Intermediate steps
- Riser height
- 6.67 in
- Risers in each return flight
- 9 risers
- Landing height
- 5 ft
- Stair width on plan
- 12.67 ft
- Stair depth on plan
- 12.33 ft
- First flight's stringer board
- 8.52 ft
- Return flights' stringer board
- 8.52 ft
- Treads in all
- 24 treads
- Handrail, total with the allowance
- 58.58 ft
- Open over each return flight
- 7.33 ft
Confidence note: WITHIN THE LIMITS CHECKED — US IRC 2024: riser height 6.67 in (169 mm) and tread depth 11.00 in (279 mm) are inside the limits this calculator checks. That is not a compliance determination: headroom, handrails, guards, nosings and width are not checked, and the building control body or inspector decides. On this page, headroom is read on its own: the opening is worked out for 2032 mm (80.0 in) of headroom over the pitch line, at or above the 6 ft 8 in (2032 mm) of IRC 2024 R311.7.2; the headroom as built is measured on site. The landing is 1524 mm (60.0 in) deep, at or over the stair's width and at least 36 in (914 mm) (IRC R311.7.6).
What this calculation does not cover
- This lays a split stair out; it does not approve it. The riser, going, landing and headroom are read against your code; the widths a split stair's flights must keep for the people it serves (its occupancy) are your building official's call.
- The stringers' depth and count, the landing's framing and its posts are your engineer's or the stair maker's: entered or left out, never sized here.
- The return flights are drawn the same width and straight; a split stair whose returns curve, or whose first flight widens at its foot, is set out by the maker.
Computed in your browser — nothing you enter is uploaded. Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.
Sources checked 2026-11-14 · 5 test vectors · v1.0.0
Regulatory standards & verification citations3
- Risers shared equally over the total rise (this site's stair rise and run rule, rounded up); each flight's stringer from this site's full-size stringer template
- US: IRC R311.7.5 and R311.7.6 (risers, treads, landings at least the stair's width and 36 in deep); UK: Approved Document K section 1 (landings at least the width of the flight); Australia: NCC Housing Provisions 11.2.5(1)(a) (landings at least 750 mm); Canada: NBC 9.8.6.3.(1)
- The opening over each return flight = nosing + (headroom + floor depth) x going / riser, as this site's stair stringer page works it
Which documents these citations point at
- International Residential Code — R311.7.5 (United States)One- and two-family dwellings and townhouses up to three storeys — structure, fire safety, energy, plumbing, mechanical and electrical in a single document.
- Approved Documents to the Building Regulations (England) — K (United Kingdom)Practical guidance on meeting the Building Regulations, one lettered part per subject — Part A structure, Part B fire, Part K protection from falling, Part L conservation of fuel and power, and the rest.
A code or standard has force only where a jurisdiction has adopted it, usually with local amendments. This site holds no adoption data for any authority, so check what is in force with the authority where you build. Any section cited above without an edition should be checked against the edition in force where you build. What it would take to know.
Cite this page
Your workspace
Most jobs need more than one number. Add the calculators you need next and they open right here, underneath this one — your figures stay on screen and nothing is lost to a page change.
The split stair drawn and counted
A scaled plan of the first flight, the landing across the whole stair and the two return flights, with the risers, stringers, treads, risers and rails, the openings above and the code readout.
Full-size stringer templates
Print the first flight's stringer and the return flights' stringer at full size, each with every notch, its foot and its head, or the one-notch step gauge both flights repeat, tiled over A4 or Letter with a calibration square and cross-hairs to line the sheets up.