Heavy Civil & Infrastructure

SPT N-Value Overburden Correction Calculator

Correct a field Standard Penetration Test (SPT) N-value for overburden pressure, per the Liao-Whitman method.

  • Answers as you type
  • Every formula cited
  • Calculated in your browser
SettingsSettings for this calculationUS
Market
Imperial · sales tax
The energy-corrected field SPT blow count (already corrected to 60% hammer efficiency).

Most modern SPT equipment and reporting already applies the 60% energy correction — check your boring log.

The effective vertical stress at the test depth.

Computed from the soil unit weight(s) above the test depth, accounting for groundwater (buoyant unit weight below the water table).

Corrected N-value (N1,60)

21.2 (N1,60)

Medium confidence

This applies overburden correction only — a complete SPT interpretation for liquefaction or bearing capacity analysis often needs additional corrections for borehole diameter, rod length, and sampler type, per the specific design method being used.

Overburden correction factor (CN)
1.41
Then change the inputs to see how far the answer moves.

Show calculation logic

How this was calculated

Formula source(s)

  • Liao, S. S. C. and Whitman, R. V. (1986), Overburden Correction Factors for SPT in Sand, ASCE Journal of Geotechnical Engineering: CN = sqrt(Pa / σ'v), capped at 2.0; corrected N-value N1(60) = CN x N60, where Pa is atmospheric pressure (~100 kPa) and σ'v is the effective vertical overburden stress

Inputs used

Field N60 Value
15
Effective Overburden Stress (σ'v)
1044.27 psf

Intermediate steps

Overburden correction factor (CN)
1.41
Final result21.21 (N1,60)

Confidence note: This applies overburden correction only — a complete SPT interpretation for liquefaction or bearing capacity analysis often needs additional corrections for borehole diameter, rod length, and sampler type, per the specific design method being used.

What this calculation does not cover

  • This applies the overburden correction and nothing else. It assumes the value you type is already energy-corrected to 60 per cent hammer efficiency, and it does not apply the rod length, borehole diameter or sampler liner corrections a full interpretation needs. A log that quotes N without saying which correction it already carries leaves that question open — settle it before entering the number, because correcting a raw field N here puts two errors in one figure with no way to separate them.
  • The overburden correction and N1,60 are granular-soil tools. A blow count taken in soft clay, silt or organic ground and corrected this way is arithmetic with no soil property behind it — cohesive strength comes from a field vane, an undrained triaxial or a piezocone sounding, not from a corrected N.
  • N1,60 is an input to liquefaction and settlement procedures, not the assessment itself. It does not apply the fines-content adjustment to an equivalent clean-sand value, and it says nothing about cyclic stress ratio, earthquake magnitude, or the seismic demand at your site.
  • The 2.0 ceiling on CN binds at any effective stress below 25 kPa, so every reading from the shallowest part of the log comes back as exactly twice the entered N60 and stops responding to depth at all. That ceiling is a practice convention rather than part of the original correction relation, and some procedures cap it lower — a shallow result here can sit above what those methods would allow.
  • It takes the effective vertical stress as given. It does not derive it from depth, unit weights and the water table, and it does not check that you used buoyant unit weight below the water table — entering total stress instead of effective overstates the stress and understates the corrected N-value. The field is in kPa and does not follow the site's metric/imperial switch, so convert a stress quoted in psf or tsf before it goes in.

Computed in your browser — nothing you enter is uploaded. Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.

Sources checked 2026-09-06 · in the site-wide review of 2026-09-06 · v1.0.1

Regulatory standards & verification citations1
  1. Liao, S. S. C. and Whitman, R. V. (1986), Overburden Correction Factors for SPT in Sand, ASCE Journal of Geotechnical Engineering: CN = sqrt(Pa / σ'v), capped at 2.0; corrected N-value N1(60) = CN x N60, where Pa is atmospheric pressure (~100 kPa) and σ'v is the effective vertical overburden stress
Cite this page

Your workspace

Most jobs need more than one number. Add the calculators you need next and they open right here, underneath this one — your figures stay on screen and nothing is lost to a page change.

Now that you have the number

These guides cover the work this quantity is for — the first ones run this calculator inside the section that raises the question.

Called something else where you work? Trench support — the term in each market, how close the equivalence really is, and the standard that governs it.

Still deciding? SPT N-Value vs Relative Density — the factors that actually differ, with no invented prices.

How to calculate SPT N-value overburden correction in 3 steps

  1. Field N60 ValueThe energy-corrected field SPT blow count (already corrected to 60% hammer efficiency).
  2. Effective Overburden Stress (σ'v)The effective vertical stress at the test depth.
  3. Corrected N-value (N1,60)The tool computes the corrected N-value (N1,60) from those figures and shows the formula, its sources, and a confidence rating alongside it.

Corrected N-value (N1,60) by effective overburden stress (σ'v)

Page defaults, not your figures above.

Effective Overburden Stress (σ'v)Corrected N-value (N1,60) ((N1,60))
500 psf30
1,000 psf21.7
1,500 psf17.7
2,000 psf15.3

Frequently asked questions

Why does the N-value need overburden correction?
The same soil density gives a higher blow count at greater depth simply because of the extra confining pressure — normalizing to a standard reference overburden (1 atmosphere) lets you compare N-values from different depths on equal footing.
Why is CN capped at 2.0?
The correction factor formula would grow indefinitely for very shallow (low overburden) tests, producing physically unrealistic results — the widely-used 2.0 cap keeps the correction from over-amplifying near-surface readings.
What is N1,60 used for?
It's the standard normalized blow count used in most simplified liquefaction assessment procedures and several bearing capacity and settlement correlations for granular soils.
Preliminary estimate, not certified engineering. This tool produces an indicative quantity calculation for planning purposes only — it is not a certified structural analysis, a guaranteed material takeoff, or a substitute for building department approval. Always verify measurements on-site and have a licensed contractor or structural engineer review any load-bearing, code-sensitive, or safety-critical work before purchasing materials or starting construction. Spotted an arithmetic or standards error? Report it to contact@craftquantities.com with your inputs — a confirmed fix gets a permanent check of its own, so the same mistake cannot come back.