  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "spt-overburden-correction-calculator",
  "category": "heavy-civil",
  "title": "SPT N-Value Overburden Correction Calculator",
  "description": "Correct a field Standard Penetration Test (SPT) N-value for overburden pressure, per the Liao-Whitman method.",
  "url": "https://craftquantities.com/calculators/heavy-civil/spt-overburden-correction-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/spt-overburden-correction-calculator.json",
  "inputCount": 2,
  "testCaseCount": 2,
  "sourceCount": 1,
  "lastVerified": "2026-09-06",
  "citation": {
    "author": "Craft Quantities",
    "title": "SPT N-Value Overburden Correction Calculator",
    "version": "1.0.1",
    "sourcesChecked": "2026-09-06",
    "url": "https://craftquantities.com/calculators/heavy-civil/spt-overburden-correction-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. SPT N-Value Overburden Correction Calculator. Version 1.0.1. Sources checked 2026-09-06. https://craftquantities.com/calculators/heavy-civil/spt-overburden-correction-calculator/",
      "apa": "Craft Quantities. (2026). SPT N-Value Overburden Correction Calculator (Version 1.0.1) [Web calculator]. Retrieved from https://craftquantities.com/calculators/heavy-civil/spt-overburden-correction-calculator/",
      "harvard": "Craft Quantities (2026) SPT N-Value Overburden Correction Calculator (Version 1.0.1). Available at: https://craftquantities.com/calculators/heavy-civil/spt-overburden-correction-calculator/",
      "bibtex": "@misc{craftquantities-calculators-heavy-civil-spt-overburden-correction-calculator,\n  author       = {{Craft Quantities}},\n  title        = {SPT N-Value Overburden Correction Calculator},\n  version      = {1.0.1},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/heavy-civil/spt-overburden-correction-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "fieldN60",
      "label": "Field N60 Value",
      "type": "number",
      "defaultValue": 15,
      "min": 1,
      "max": 100,
      "step": 1,
      "help": "The energy-corrected field SPT blow count (already corrected to 60% hammer efficiency)."
    },
    {
      "id": "effectiveOverburdenStress",
      "label": "Effective Overburden Stress (σ'v)",
      "type": "number",
      "dimension": "pressure",
      "defaultValue": 50000,
      "min": 5000,
      "max": 400000,
      "step": 1000,
      "help": "The effective vertical stress at the test depth."
    }
  ],
  "sources": [
    {
      "label": "Liao, S. S. C. and Whitman, R. V. (1986), Overburden Correction Factors for SPT in Sand, ASCE Journal of Geotechnical Engineering: CN = sqrt(Pa / σ'v), capped at 2.0; corrected N-value N1(60) = CN x N60, where Pa is atmospheric pressure (~100 kPa) and σ'v is the effective vertical overburden stress"
    }
  ],
  "testCases": [
    {
      "name": "N60=15, σ'v=50kPa (50,000 Pa in the base)",
      "inputs": {
        "fieldN60": 15,
        "effectiveOverburdenStress": 50000
      },
      "expected": 21.21,
      "toleranceDecimalPlaces": 1,
      "unit": "(N1,60)",
      "confidence": "medium",
      "steps": [
        {
          "label": "Overburden correction factor (CN)",
          "value": 1.4142135623730951
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    },
    {
      "name": "N60=20, σ'v=150kPa (150,000 Pa in the base)",
      "inputs": {
        "fieldN60": 20,
        "effectiveOverburdenStress": 150000
      },
      "expected": 16.33,
      "toleranceDecimalPlaces": 2,
      "unit": "(N1,60)",
      "confidence": "medium",
      "steps": [
        {
          "label": "Overburden correction factor (CN)",
          "value": 0.816496580927726
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    }
  ]
}