SettingsSettings for this calculationUS
Full treads, or paddles that alternate sides.
On an alternating tread stair each foot steps between nosings on its own side: twice the going and twice the riser.
Finished floor below to finished floor above.
Measured on site with the finishes each floor will carry; the risers share it equally.
The rise per step you want.
Rounded up into whole risers, so none is taller: the IRC allows 9 1/2 in, Approved Document K 220 mm on an alternating tread stair.
A pitch, or the floor space the ladder may take.
The run is the pitch line's, from where it meets the lower floor to the upper floor's edge.
The angle of the pitch line from the floor.
Steeper takes less floor and leaves a shorter going; the IRC's 5 in going and 9 1/2 in riser meet at about 62°.
The tread board's own depth.
Deeper than the going, it runs under the tread above: the IRC's tread depth plus nosing projection.
Sets each trench's width.
The trench is the tread's thickness.
Clear between the stringers.
Handrails inside the stringers narrow it; the IRC asks 20 in at and below them.
Your board; never recommended here.
Sets the throat under the trenches.
Stringer top edge to the pitch line, square to it.
A larger margin leaves less throat.
Upper floor to the ceiling below.
Sets the opening with the headroom.
Clear height over the pitch line.
Approved Document K asks 2 m over an alternating tread stair.
The code the riser, going, treads and width are read against.
Figures compared with the code's own, never compliance: the building official or building control body decides. Where this page does not read a code's figures it says so rather than guessing them.
Risers
12 risers
WITHIN THE LIMITS CHECKED — riser 216 mm (8.50 in), going 135 mm (5.31 in), tread 222 mm (8.75 in) deep, 58.0° pitch, 610 mm (24.00 in) between the stringers, inside the figures this page reads for IRC R311.7.12. Limits checked, not an approval. A ship's ladder is not an element of a means of egress under the IRC, and takes a handrail on both sides.
- Riser height
- 8.5 in · 8 1/2 in
- Going, nosing to nosing
- 5.31 in · 5 5/16 in
- Pitch
- 58 °
- Treads
- 11 treads
- Tread overlap under the one above
- 3.44 in · 3 7/16 in
- Same-foot going (alternating)
- 5.31 in · 5 5/16 in
- Run, floor to the upper floor's edge
- 5.31 ft · 5 ft 3 3/4 in
- Stringer board length
- 10.16 ft · 10 ft 1 15/16 in
- Trench to trench along the stringer
- 10.02 in
- Throat under the trenches
- 0.92 in · 15/16 in
- Opening in the floor above
- 4.62 ft · 4 ft 7 7/16 in
- Handrail each side
- 10.02 ft · 10 ft 0 1/4 in
They open the calculator with your figures already in it
Ship's Ladder and Alternating Tread Stair Calculator (Loft and Attic Stairs: Risers, Pitch and Stringers): 12 risers — shown in imperial, US market. The link sets both, so the result they see is the one on your screen.
Show calculation logicHide calculation logic
How this was calculated
Formula source(s)
- US: IRC R311.7.11 and R311.7.12 — alternating tread devices and ship's ladders not an element of a means of egress, the clear width at and below the handrails at least 20 in (508 mm); R311.7.11.1 and R311.7.12.1 — tread depth at least 5 in, tread depth plus nosing projection at least 8 1/2 in, riser at most 9 1/2 in, an alternating tread at least 7 in wide; handrails on both sides
- UK: Approved Document K (2013 edition), 1.29–1.30 and Diagram 1.10 — alternating tread stairs only in a loft conversion serving one habitable room, uniform steps with parallel nosings, slip-resistant treads, handrails both sides, rise at most 220 mm, going at least 220 mm measured between alternate nosings, 2 m headroom; 1.32 — a fixed ladder with handrails both sides only for a loft conversion of one habitable room
- Going = riser / tan(pitch); trench spacing along the stringer = sqrt(going^2 + riser^2); the opening in the floor above = (headroom + floor depth) x going / riser, as this site's stair stringer page works it
Inputs used
- Kind
- Ship's ladder (full-width treads)
- Total Rise (floor to floor)
- 8.5 ft
- Riser You Are Aiming For
- 8.75 in
- Set by
- The pitch
- Pitch (°)
- 58
- Run available
- 4.5 ft
- Tread depth (front to back)
- 8.75 in
- Tread thickness
- 1.25 in
- Width between the stringers
- 2 ft
- Paddle width
- 11.75 in
- Stringer board depth
- 9.75 in
- Margin above the nosings
- 0.75 in
- Floor depth at the opening
- 9.75 in
- Headroom to keep
- 79 in
- Code for the readout
- US — IRC
Intermediate steps
- Riser height
- 8.5 in
- Going, nosing to nosing
- 5.31 in
- Pitch
- 58 °
- Treads
- 11 treads
- Tread overlap under the one above
- 3.44 in
- Same-foot going (alternating)
- 5.31 in
- Run, floor to the upper floor's edge
- 5.31 ft
- Stringer board length
- 10.16 ft
- Trench to trench along the stringer
- 10.02 in
- Throat under the trenches
- 0.92 in
- Opening in the floor above
- 4.62 ft
- Handrail each side
- 10.02 ft
Confidence note: WITHIN THE LIMITS CHECKED — riser 216 mm (8.50 in), going 135 mm (5.31 in), tread 222 mm (8.75 in) deep, 58.0° pitch, 610 mm (24.00 in) between the stringers, inside the figures this page reads for IRC R311.7.12. Limits checked, not an approval. A ship's ladder is not an element of a means of egress under the IRC, and takes a handrail on both sides.
What this calculation does not cover
- This lays a steep stair out; it does not approve one, and it cannot say whether your building may have one at all: that is your building official's or building control's call.
- The stringer board is your figure: its depth sets the throat shown, and whether it spans from floor to head with its fixings is your engineer's or the maker's to determine.
- Where either may be used is the code's first rule: neither is an element of a means of egress under the IRC, and Approved Document K allows them only in a loft conversion of one habitable room with too little room for a stair. Check the use before the geometry.
- Treads are housed in the stringers; a ladder on brackets or cleats sets out the same marks but has no trenches. The handrails' brackets and the fixings at the head and foot are the maker's.
- The Australian and Canadian codes' figures for these stairs are not read here.
Computed in your browser — nothing you enter is uploaded. Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.
Sources checked 2026-11-13 · 5 test vectors · v1.0.0
Regulatory standards & verification citations3
- US: IRC R311.7.11 and R311.7.12 — alternating tread devices and ship's ladders not an element of a means of egress, the clear width at and below the handrails at least 20 in (508 mm); R311.7.11.1 and R311.7.12.1 — tread depth at least 5 in, tread depth plus nosing projection at least 8 1/2 in, riser at most 9 1/2 in, an alternating tread at least 7 in wide; handrails on both sides
- UK: Approved Document K (2013 edition), 1.29–1.30 and Diagram 1.10 — alternating tread stairs only in a loft conversion serving one habitable room, uniform steps with parallel nosings, slip-resistant treads, handrails both sides, rise at most 220 mm, going at least 220 mm measured between alternate nosings, 2 m headroom; 1.32 — a fixed ladder with handrails both sides only for a loft conversion of one habitable room
- Going = riser / tan(pitch); trench spacing along the stringer = sqrt(going^2 + riser^2); the opening in the floor above = (headroom + floor depth) x going / riser, as this site's stair stringer page works it
Which documents these citations point at
- International Residential Code — R311.7.11 (United States)One- and two-family dwellings and townhouses up to three storeys — structure, fire safety, energy, plumbing, mechanical and electrical in a single document.
- Approved Documents to the Building Regulations (England) — K (United Kingdom)Practical guidance on meeting the Building Regulations, one lettered part per subject — Part A structure, Part B fire, Part K protection from falling, Part L conservation of fuel and power, and the rest.
A code or standard has force only where a jurisdiction has adopted it, usually with local amendments. This site holds no adoption data for any authority, so check what is in force with the authority where you build. Any section cited above without an edition should be checked against the edition in force where you build. What it would take to know.
Cite this page
Your workspace
Most jobs need more than one number. Add the calculators you need next and they open right here, underneath this one — your figures stay on screen and nothing is lost to a page change.
The ladder drawn and its stringers set out
A scaled side elevation of the stringer with each tread's trench and the pitch line, the going, overlap and pitch, the opening above and the parts, with the code readout.
Full-size stringer templates
Print one tread's trench as a router gauge, or the whole stringer with every trench, the level cut at the foot and the plumb cut at the head, with a calibration square on every sheet.