The total R-value required by your frost-protected shallow foundation design.
This target comes from your local frost depth and climate zone requirements, not a fixed universal number.
The rated thermal resistance per inch of thickness for the specific rigid insulation board.
Check the manufacturer's data sheet — common rigid foam boards range roughly from R-3.6 to R-6.5 per inch depending on the foam type.
Required insulation thickness
2 in
Target R-value for frost-protected shallow foundations (FPSF) depends on your local frost depth/climate zone per IRC Appendix AF or local code — confirm the required R-value for your specific location before sizing insulation thickness.
They open the calculator with your figures already in it
Foundation Frost-Protection Insulation Depth Calculator: 2 in — shown in imperial, US market. The link sets both, so the result they see is the one on your screen.
Show calculation logicHide calculation logic
How this was calculated
Formula source(s)
- Required thickness = target R-value ÷ the insulation board's rated R-value per inch, the same relationship used for any rigid foam insulation thickness sizing
Inputs used
- Target R-Value (Per Frost-Protection Design)
- 10
- Board R-Value per Inch
- 5
Confidence note: Target R-value for frost-protected shallow foundations (FPSF) depends on your local frost depth/climate zone per IRC Appendix AF or local code — confirm the required R-value for your specific location before sizing insulation thickness.
What this calculation does not cover
- The rated R per inch is a dry laboratory figure at a mean temperature around 75°F, and buried foam is neither dry nor at 75°F. Boards in wet ground take up water and lose resistance as they do, extruded polystyrene sheds blowing agent over decades toward a lower aged value, and polyiso — which is what the top of this input's range describes — absorbs water badly and is generally not accepted below grade at all. Choose a product the FPSF detail permits underground first, then read its R per inch off that product's sheet.
- The answer is a raw division, not a stock thickness. Foam comes in fixed thicknesses, so 3.33 in (85 mm) means two layers, and two layers only deliver the calculated figure if their joints are offset — aligned seams leave a straight thermal path through the whole assembly at every one. The portion above grade also needs a protective covering against sunlight and impact, which adds thickness the trench width and the finish detail have to accommodate.
Add the equipment this sizes
This result is a specification — 2 in — not a quantity. Put the thing it sizes into your project: how many, what you call it, and your supplier’s price.
Computed in your browser — nothing you enter is uploaded. Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.
Sources checked 2026-09-06 · in the site-wide review of 2026-09-06 · v1.0.1
Regulatory standards & verification citations1
- Required thickness = target R-value ÷ the insulation board's rated R-value per inch, the same relationship used for any rigid foam insulation thickness sizing
Cite this page