SettingsSettings for this calculationUS
The face area of sheathing or masonry receiving the barrier.
Measure the surface the roller or spray gun will actually cross. Openings can be deducted, but the reveals and returns around them cannot — those are surfaces too, and they are added below along with everything else that gets a detail band.
The wet build the manufacturer specifies for a single coat.
Take this straight from the product data sheet and check it on the wall with a wet film gauge as you go, because it is the only variable in this calculation that anyone can get wrong while working. US data sheets usually state it in mils, thousandths of an inch: 30 mils is 0.76 mm. Note whether the sheet's figure is a wet or a dry film thickness — the dry figure is smaller by the solids content, and applying to it leaves the barrier thin.
How many passes the specification calls for over the field of the wall.
Two passes in opposing directions are common, because a single pass leaves pinholes wherever the substrate texture shades the roller. Where a system permits one coat, the stated wet build for that coat is usually higher, so change both figures together rather than halving one of them.
The running length of sheathing joints, corners, transitions and opening perimeters.
Add up every line that gets a detail band: sheathing joints, inside and outside corners, the perimeter of each rough opening, penetration collars, and every transition to a different material. This is routinely the item that runs short, because it is measured last and it is longer than it looks.
Tools needed: Elevation drawings with opening schedule, Measuring wheel
How wide a band of material each detail line receives.
The band is the strip of barrier laid down to bed the tape or fabric, and it is wider than the tape itself so the reinforcement is fully embedded rather than sitting on the edge of wet material. The manufacturer's detail drawings state it; where they state a tape width instead, allow the tape width plus a margin each side.
The extra length ordered to cover end laps, corner wraps and offcuts.
Reinforcement is lapped at every joint in the reinforcement itself, wrapped around corners rather than butted, and cut to waste at the end of each roll. Ten percent is a modest allowance on a simple elevation; a facade full of small openings consumes far more, because every opening is four corners.
Barrier material required
46.2 gal
Volume follows exactly from thickness and area, so the accuracy of the answer is the accuracy of the wet build achieved on the wall. Spray application over a rough substrate consistently uses more than the arithmetic predicts, and rolled work over open-textured sheathing more again.
- Coated area including the detail band
- 1,177.5 ft²
- Material for a single coat
- 23.12 gal
- Detail tape or reinforcing mesh to order
- 214.5 ft
- Wet build applied in each pass
- 0.03 in
They open the calculator with your figures already in it
Fluid-Applied Weather Barrier Coating Coverage Calculator: 46.24 gal — shown in imperial, US market. The link sets both, so the result they see is the one on your screen.
Show calculation logicHide calculation logic
How this was calculated
Formula source(s)
- ASTM E2570, Standard Test Methods for Evaluating Water-Resistive Barrier (WRB) Coatings and Systems Used under Exterior Insulation and Finish Systems (EIFS) or EIFS with Drainage — the barrier's performance is evaluated at the wet film thickness the manufacturer states, which is why thickness rather than a headline coverage rate is the input here
- Volume = coated area × wet film thickness × number of coats. One millimetre of wet film over one square metre is one litre of material, by definition of the litre
Inputs used
- Substrate Area to be Coated
- 1080 sq ft
- Wet Film Thickness per Coat
- 0.03 in
- Number of Coats
- 2
- Length of Joints and Details to be Treated
- 195 ft
- Width of the Detail Band
- 6 in
- Lap and Waste Allowance on Tape or Mesh (%)
- 10
Intermediate steps
- Coated area including the detail band
- 1,177.5 ft²
- Material for a single coat
- 23.12 gal
- Detail tape or reinforcing mesh to order
- 214.5 ft
- Wet build applied in each pass
- 0.03 in
Confidence note: Volume follows exactly from thickness and area, so the accuracy of the answer is the accuracy of the wet build achieved on the wall. Spray application over a rough substrate consistently uses more than the arithmetic predicts, and rolled work over open-textured sheathing more again.
What this calculation does not cover
- Excludes the extra material a rough or absorbent substrate drinks on the first pass, and excludes overspray, which on an exposed elevation is not a small number.
- Excludes primer, flashing membranes, sill pans and penetration boots — those are separate products with their own coverage, and none of them can be retrofitted through a bonded laminate afterwards.
- Assumes the stated thickness is a WET film. A dry film thickness converts by the product's solids content, and applying a wet build to a dry figure leaves the barrier short of the thickness it was tested at.
Estimated cost — your price
This site holds no price list for this material — local prices vary too much to publish honestly. Enter your supplier's price and the result is costed with it.
Computed in your browser — nothing you enter is uploaded. Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.
Sources checked 2026-08-30 · in the site-wide review of 2026-09-06 · v1.0.0
Regulatory standards & verification citations2
- ASTM E2570, Standard Test Methods for Evaluating Water-Resistive Barrier (WRB) Coatings and Systems Used under Exterior Insulation and Finish Systems (EIFS) or EIFS with Drainage — the barrier's performance is evaluated at the wet film thickness the manufacturer states, which is why thickness rather than a headline coverage rate is the input here
- Volume = coated area × wet film thickness × number of coats. One millimetre of wet film over one square metre is one litre of material, by definition of the litre
Which documents these citations point at
Standards referenced: ASTM E2570 (ASTM International, United States).
Cite this page
Your workspace
Most jobs need more than one number. Add the calculators you need next and they open right here, underneath this one — your figures stay on screen and nothing is lost to a page change.