SettingsSettings for this calculationUS
The total height of the wall receiving the clip grid.
Measure the full vertical run of the wall that will carry the continuous insulation attachment system.
The vertical spacing between clip rows.
Clip spacing is typically set by the thermal clip manufacturer based on the insulation thickness and structural loading — confirm against their engineering data.
The total width of the wall receiving the clip grid.
Measure the full horizontal run of the wall that will carry the continuous insulation attachment system.
The horizontal spacing between clips within a row.
This is a thermal decision as much as a structural one, and the two pull against each other: every clip is a path through the insulation, so a tighter grid supports the cladding better and performs worse. Decide the trade deliberately rather than setting the structural spacing first and inheriting whatever thermal performance falls out of it — which is how a wall ends up with continuous insulation that is not continuous.
Total thermal break clips needed
108 clips
- Rows
- 6
- Clips per row
- 18
They open the calculator with your figures already in it
Thermal Break Clip Spacing Calculator: 108 clips — shown in imperial, US market. The link sets both, so the result they see is the one on your screen.
Show calculation logicHide calculation logic
How this was calculated
Formula source(s)
- Clip grid count = (rows = ceil(wall height ÷ vertical spacing) + 1) × (clips per row = ceil(wall width ÷ horizontal spacing) + 1), the standard method for laying out a two-way fastening grid
Inputs used
- Wall Height
- 10 ft
- Vertical Clip Spacing
- 2 ft
- Wall Width
- 33 ft
- Horizontal Clip Spacing
- 2 ft
Intermediate steps
- Rows
- 6
- Clips per row
- 18
What this calculation does not cover
- Accepts any horizontal spacing, but clips have to hit STRUCTURE. The screws pass through the sheathing into studs or girts, so horizontal spacing is fixed by the framing behind — 400 or 600 mm (16 or 24 in), whatever the wall was framed at — and only the vertical spacing is genuinely free. A grid set out to a round number lands clips in empty sheathing, where they hold nothing and the cladding hangs on the few that happened to find framing.
Estimated cost — your price
This site holds no price list for this material — local prices vary too much to publish honestly. Enter your supplier's price and the result is costed with it.
Computed in your browser — nothing you enter is uploaded. Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.
Sources checked 2026-09-06 · 2 test vectors · in the site-wide review of 2026-09-06 · v1.0.1
Regulatory standards & verification citations1
- Clip grid count = (rows = ceil(wall height ÷ vertical spacing) + 1) × (clips per row = ceil(wall width ÷ horizontal spacing) + 1), the standard method for laying out a two-way fastening grid