What it is called, by market
One concept, four markets. Where a name means something else locally, the card says so rather than leaving you to find out on site.
United Kingdom
Same word, different thingsuspended timber floor
also suspended floor, underfloor void, sleeper wall, honeycomb wall
Names the FLOOR. A SLEEPER or HONEYCOMB wall is the low dwarf wall built with gaps in it to carry the joists mid-span while letting air pass — a component with no standard American name.
Australia
Same word, different thingsuspended floor
also subfloor, underfloor space, bearers and joists
SUBFLOOR in Australian usage means the whole space and structure beneath the floor, where American usage means the sheet material you walk on before the finish goes down.
United Statesyours
Same word, different thingcrawlspace
also crawl space, vented crawlspace, conditioned crawlspace, pier and beam
Names the SPACE. And current American practice increasingly SEALS and conditions that space, which is the opposite of the ventilation British practice depends on.
Canada
Close, not identicalcrawlspace
also crawl space, heated crawlspace
As the United States, with sealing and heating the space the normal approach given the frost depth and the winter humidity ratio.
The governing standard, by market
United Kingdom
Approved Document C / BS 8103-1
Site preparation and resistance to moisture including underfloor ventilation, and structural design of low-rise buildings.
United States
IRC R408 / ASHRAE 62.2
Under-floor space ventilation and the conditions for an unvented conditioned crawlspace, and residential ventilation.
Calculators for this
Each works in either measurement system, and the terminology on the page follows whichever market you have selected.
Frequently asked questions
- Ventilate the void or seal it — why do the markets disagree?
- Because they are solving for different climates and different moisture sources, and both positions are coherent. The BRITISH approach ventilates: airbricks through the external wall on at least two opposite sides give a cross-flow that carries away moisture evaporating from the ground, and blocking them is one of the most reliable ways to rot a floor. That works in a mild, damp climate where outdoor air is rarely much wetter than the void. The AMERICAN approach increasingly SEALS: a ground-covering vapour barrier, sealed vents, insulation at the foundation walls, and the space brought inside the building's thermal envelope. That works where summer outdoor air is far more humid than the cool void, so ventilating it CONDENSES moisture into the space rather than removing it. Applying either approach in the other's climate produces the failure it was designed to prevent.
- What is a sleeper wall, and why is it built with gaps?
- It is a low wall in the void, part-way across the span, carrying a wall plate that the joists sit on — so the joists span from external wall to sleeper wall rather than the full width of the room, which lets a much smaller section be used. It is built HONEYCOMB, with the bricks spaced so there are openings right through it, because a solid wall across the void would block the cross-ventilation the whole floor depends on. Every sleeper wall also sits on its own footing with a damp-proof course under the plate. Two things go wrong with them in practice: the honeycomb gets filled in during later work, which kills the airflow beyond it, and the DPC under the plate is omitted or bridged, which rots the plate the joists are sitting on.
- Why does insulating one of these floors go wrong so often?
- Because the insulation is usually added from below without changing anything else, and it alters the void's behaviour in two ways at once. It makes the void COLDER, since the heat leaking down from the house was quietly keeping it above the dew point — so the same outdoor air that was harmless before now condenses in it. And it frequently obstructs the airflow the ventilation depends on, because insulation fitted between joists is pushed toward the eaves of the void or tucked into the airbricks. The result is a floor that was dry for a century and rots within a few years of being improved. The fix is not to avoid insulating; it is to treat the void's ventilation, the ground covering and the insulation as one system rather than adding one of the three.