SettingsSettings for this calculationUS
The most people working on site at one time, all trades together.
Count everyone who will use the facilities at the peak of the job — every contractor's operatives, not only your own — because the facilities are shared and sized for the busiest day, not the average one.
Which published table the counts come from.
The two tables differ in shape: the British one steps up at fixed headcounts and pairs every toilet with a washing station; OSHA's sets a ratio of toilet seats and urinals per worker for construction sites and says nothing numerical about washing. Other countries publish their own ratios.
Toilets, minimum
3 toilets
For 30 people, Table 1 of L24 gives 3 toilets and 3 washing stations. The ACoP has a second table for men only, with urinals, which this page does not apply; on a construction site CDM 2015 Schedule 2 asks for facilities that are suitable and sufficient, and L24's numbers are the published measure of sufficient.
- Washing stations
- 3 washing stations
- People per toilet
- 10 people
They open the calculator with your figures already in it
Site Welfare Toilets and Washing Stations Calculator: 3 toilets — shown in imperial, US market. The link sets both, so the result they see is the one on your screen.
Show calculation logicHide calculation logic
How this was calculated
Formula source(s)
- Workplace (Health, Safety and Welfare) Regulations 1992, Approved Code of Practice L24, Table 1 (mixed use or women): 1 to 5 people, 1 toilet and 1 washing station; 6 to 25, 2 of each; 26 to 50, 3; 51 to 75, 4; 76 to 100, 5; and above 100, one more of each for every 25 people or part of 25
- Construction (Design and Management) Regulations 2015, Schedule 2: suitable and sufficient sanitary conveniences and washing facilities must be provided or made available at readily accessible places on a construction site
- 29 CFR 1926.51(c)(1), Table D-1: 20 employees or fewer, 1 toilet; 20 or more, 1 toilet seat and 1 urinal per 40 workers; 200 or more, 1 toilet seat and 1 urinal per 50 workers — and where the facilities will not be used by women, urinals may replace toilet seats down to two-thirds of the minimum number of seats
Inputs used
- People on Site at the Busiest Time
- 30
- Table to Apply
- Great Britain — Workplace Regulations ACoP L24, Table 1
Intermediate steps
- Washing stations
- 3 washing stations
- People per toilet
- 10 people
Confidence note: For 30 people, Table 1 of L24 gives 3 toilets and 3 washing stations. The ACoP has a second table for men only, with urinals, which this page does not apply; on a construction site CDM 2015 Schedule 2 asks for facilities that are suitable and sufficient, and L24's numbers are the published measure of sufficient.
What this calculation does not cover
- These are minimum numbers of fittings, not a welfare design. Separate facilities for men and women, an accessible facility, heating, lighting, ventilation and a regular cleaning and servicing schedule are all required on top.
- Washing facilities need hot and cold or warm running water, soap and a means of drying, and should be next to the toilets and near changing areas; a basin count alone does not describe them.
- Rest areas, drinking water, changing rooms and somewhere to store and dry clothing are part of site welfare too and are not counted here.
- The count is for people working at one time. A site whose peak is short but intense is sized for the peak.
Estimated cost — your price
This site holds no price list for this material — local prices vary too much to publish honestly. Enter your supplier's price and the result is costed with it.
Computed in your browser — nothing you enter is uploaded. Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.
Sources checked 2026-09-21 · v1.0.0
Regulatory standards & verification citations3
- Workplace (Health, Safety and Welfare) Regulations 1992, Approved Code of Practice L24, Table 1 (mixed use or women): 1 to 5 people, 1 toilet and 1 washing station; 6 to 25, 2 of each; 26 to 50, 3; 51 to 75, 4; 76 to 100, 5; and above 100, one more of each for every 25 people or part of 25
- Construction (Design and Management) Regulations 2015, Schedule 2: suitable and sufficient sanitary conveniences and washing facilities must be provided or made available at readily accessible places on a construction site
- 29 CFR 1926.51(c)(1), Table D-1: 20 employees or fewer, 1 toilet; 20 or more, 1 toilet seat and 1 urinal per 40 workers; 200 or more, 1 toilet seat and 1 urinal per 50 workers — and where the facilities will not be used by women, urinals may replace toilet seats down to two-thirds of the minimum number of seats