SettingsSettings for this calculationUS
The floor's length in the direction the bearers run.
Measure to the outside of the subfloor frame, along the bearers.
Tools needed: Tape measure
The floor's width, across the bearers, which the joists span.
Measure to the outside of the subfloor frame, across the bearers.
Tools needed: Tape measure
Centre to centre of the bearer lines: the joists' span, from your span tables or engineer.
The joist size you use decides how far apart the bearers may be (AS 1684 span tables). 1800 mm is an example to replace, never a recommendation.
Centre to centre of the stumps under one bearer: the bearer's span, from your span tables or engineer.
The bearer section decides how far apart its stumps may be. 1800 mm is an example to replace.
The length the bearers are bought in.
Australian structural timber is sold in 0.3 m steps; 5.4 and 6.0 m are common long lengths. Each join must land over a stump.
The side of each square footing, from your engineer or footing detail.
Footing sizes come from the soil classification and the load (AS 2870 and your engineer). 400 mm is an example to replace; enter 0 to leave the concrete out.
The depth of concrete in each footing hole, from your engineer or footing detail.
600 mm is an example to replace.
Stumps
48 stumps
- Bearer lines
- 6 lines
- Stumps under each bearer line
- 8 stumps
- Bearer run, all lines
- 234 ft
- Bearer stock lengths to buy
- 18 lengths
- Bearer joins, each over a stump
- 12 joins
- Footing concrete, all stumps
- 6.32 yd³
They open the calculator with your figures already in it
Stumps and Bearers Calculator — Subfloor Framing: Stump Count and Bearer Lengths: 48 stumps — shown in imperial, US market. The link sets both, so the result they see is the one on your screen.
Show calculation logicHide calculation logic
How this was calculated
Formula source(s)
- Bunnings, how to install stumps: stump and bearer positions are taken from the timber span tables for the job; stumps are set in concrete footings and strung to height
- RMIT Learning Lab, BuildRight, sub-floor bearers: bearers are sized and spaced from the span tables in AS 1684, Residential timber-framed construction, which also need the site's wind classification
- Standards Australia, AS 1684.2 Residential timber-framed construction, Part 2: Non-cyclonic areas — the span tables named as the reader's reference; nothing here reads them
Inputs used
- Floor Length (Along the Bearers)
- 39 ft
- Floor Width (Across the Bearers)
- 26 ft
- Bearer Spacing (Centres)
- 71 in
- Stump Spacing Along a Bearer
- 71 in
- Bearer Stock Length
- 17.5 ft
- Stump Footing Pad Side
- 16 in
- Stump Footing Depth
- 24 in
Intermediate steps
- Bearer lines
- 6 lines
- Stumps under each bearer line
- 8 stumps
- Bearer run, all lines
- 234 ft
- Bearer stock lengths to buy
- 18 lengths
- Bearer joins, each over a stump
- 12 joins
- Footing concrete, all stumps
- 6.32 yd³
What this calculation does not cover
- Nothing here is sized. The bearer section, the bearer and stump spacings, the stump type and the footing come from the AS 1684 span tables for your timber, load and wind classification, or from your engineer; the page counts what those figures make.
- The floor is one rectangle with the bearers running its length. An L-shaped floor is entered as two rectangles; a line of bearers shared between them is then counted twice, so take one line off.
- Bearer joins are assumed to land over a stump, as they must. Where a stock length does not reach the next stump, the join moves back to the stump before it and the offcut is lost; the stock count does not model that.
- Bracing, ant capping, stump-to-bearer connectors and the joists are separate items: the Floor Joist Quantity Calculator counts the joists on these bearers.
Estimated cost — your price
This site holds no price list for this material — local prices vary too much to publish honestly. Enter your supplier's price and the result is costed with it.
Computed in your browser — nothing you enter is uploaded. Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.
Sources checked 2026-10-31 · 2 test vectors · v1.0.0
Regulatory standards & verification citations3
- Bunnings, how to install stumps: stump and bearer positions are taken from the timber span tables for the job; stumps are set in concrete footings and strung to height
- RMIT Learning Lab, BuildRight, sub-floor bearers: bearers are sized and spaced from the span tables in AS 1684, Residential timber-framed construction, which also need the site's wind classification
- Standards Australia, AS 1684.2 Residential timber-framed construction, Part 2: Non-cyclonic areas — the span tables named as the reader's reference; nothing here reads them