SettingsSettings for this calculationUS
The room's length, wall to wall, at ceiling height.
Measure at the height the ceiling will hang, wall face to wall face. Check both ends: a room that is not square needs its borders cut to a taper, which no count captures.
Tools needed: Tape measure
The room's width, wall to wall, at right angles to the length.
The page works the grid on the length and width as a rectangle; an L-shaped room is run as two rectangles.
Tools needed: Tape measure
The panels the grid holds: 2 x 2 or 2 x 4 ft, or 600 x 600 or 1200 x 600 mm.
Both use the same main beams and long cross tees; 2 x 2 panels add a short cross tee down the middle of every 2 x 4 opening. A metric grid is a true 600 mm (23.6 in) module and an imperial one 2 ft (610 mm), so pick the grid you are buying: the two set a room out slightly differently.
Main beams run at right angles to the joists they hang from, Armstrong says.
Find which way the joists or the structure above run and lay the mains across them, so each hanger wire lands on a joist. The choice changes which dimension is divided into 4 ft (1200 mm) bays and which into 2 ft (600 mm) ones, and so the counts and the borders.
The length one main beam comes in: 3.6 m (11.8 ft) for the metric Prelude main tee, 12 ft (3.66 m) for Armstrong's.
The metric grid opens on the 3.6 m (11.8 ft) Armstrong Prelude main tee a UK merchant sells for 600 mm panels; the 2 ft grid on Armstrong's 12 ft (3.66 m) Prelude main beam, which Kanopi also sells 6 ft (1.83 m) long. Enter the length on the box you are buying.
The length one piece of wall angle (wall molding) comes in: 3 m (9.8 ft) for the metric Prelude, 12 ft (3.66 m) for Armstrong's.
Armstrong's Prelude wall angle is sold in 3 m (9.8 ft) lengths in the UK and its wall molding in 12 ft (3.66 m) lengths in North America. Enter the length of the angle you are buying.
How far apart the hanger wires go along a main beam: 4 ft (1.2 m) in Armstrong's instructions.
Armstrong snaps the lines for the mains 4 ft (1.2 m) apart and puts the wire fasteners 4 ft (1.2 m) apart along them. Light fittings take their own extra wires, and a seismic area or the grid maker's own table can call for closer spacing; enter what applies.
Main beams to order
5 main beams
The grid follows Armstrong's instructions: main beams on the long module, cross tees between them on the short one, borders of the remainder plus one panel shared equally between opposite walls, a 2 ft (600 mm) tee splitting each opening for 2 x 2 panels, and hangers at the spacing entered along every main. Main beam offcuts start the next rows, as Armstrong suggests; cross tees are counted one to each opening, border tees included.
- Lines of main beams
- 3 lines
- Long cross tees, border tees included
- 32 tees
- Short cross tees, for 2 x 2 panels
- 27 tees
- Wall angle pieces
- 5 pieces
- Hanger wires
- 15 wires
- Border across the mains, at each wall
- 1.5 ft
- Border along the mains, at each end
- 1.25 ft
- Perimeter for the wall angle
- 59 ft
They open the calculator with your figures already in it
Drop or Suspended Ceiling Grid Calculator — Main Tees, Cross Tees, Wall Angle and Hangers: 5 main beams — shown in imperial, US market. The link sets both, so the result they see is the one on your screen.
Show calculation logicHide calculation logic
How this was calculated
Formula source(s)
- Armstrong World Industries, How to Install Your Armstrong Suspended Ceiling (general installation instructions): main beams installed perpendicular to the joists on 4' centres; snap chalk lines for main beams 4' apart and screw in wire fasteners 4' apart; cross tees 2' apart for 2' x 4' panels; border panels the same size on opposite sides and as large as possible, found from the remainder plus one panel length divided by two (the sample 9' x 10' 6" room: 2' 6" and 1' 3" borders); for 2' x 2' panels the first main beam at the border panel size or the border panel + 24" from the wall; additional hanger wires may be needed for light fixtures
- Kanopi by Armstrong, How to Install Drop Ceilings: main beams carry the load of the grid, typically 12' or 6'; cross tees attach perpendicular to the main beams to make the 24" x 24" or 24" x 48" openings; wall moldings finish the perimeter; hanger wires attach to the joists; the left-over ends of cut main beams start additional rows
- Kanopi by Armstrong, ceiling grid range: 12' Wall Molding, Prelude 12' Heavy Duty Main Beam, Prelude 2' Cross Tee
- Judge Ceilings, Armstrong Ceiling Grid (UK merchant listing): 3.6m Armstrong Prelude Main Tees; Armstrong Prelude 1200mm Cross Tee; Armstrong Prelude 600mm Cross Tee; Armstrong Prelude Wall Angle 3m
Inputs used
- Room Length
- 16.5 ft
- Room Width
- 13 ft
- Panel Size
- 2 x 2 ft
- Which Way the Main Beams Run
- Along the room's length
- Main Beam Length as Sold
- 12 ft
- Wall Angle Length as Sold
- 12 ft
- Hanger Spacing Along Each Main
- 4 ft
Intermediate steps
- Lines of main beams
- 3 lines
- Long cross tees, border tees included
- 32 tees
- Short cross tees, for 2 x 2 panels
- 27 tees
- Wall angle pieces
- 5 pieces
- Hanger wires
- 15 wires
- Border across the mains, at each wall
- 1.5 ft
- Border along the mains, at each end
- 1.25 ft
- Perimeter for the wall angle
- 59 ft
Confidence note: The grid follows Armstrong's instructions: main beams on the long module, cross tees between them on the short one, borders of the remainder plus one panel shared equally between opposite walls, a 2 ft (600 mm) tee splitting each opening for 2 x 2 panels, and hangers at the spacing entered along every main. Main beam offcuts start the next rows, as Armstrong suggests; cross tees are counted one to each opening, border tees included.
What this calculation does not cover
- This counts the components of a standard lay-in grid in a rectangular room, laid out as the maker's instructions describe. It is not a design: hanger spacing in seismic areas, bracing, the weight the grid may carry and the support of light fittings, which Armstrong says may need additional hanger wires, are the grid maker's and the building code's.
- Every cross tee position takes a whole tee, so the cut border tees each count as one. A 4 ft (1200 mm) tee cut for a narrow border sometimes leaves an offcut long enough for the opposite wall, which this count does not assume.
- The main beams are the length of all the main lines over the stock length, using offcuts to start further rows; where the offcuts are too short to reuse, each line takes its own pieces and the count rises. Splices between main beam pieces need a hanger close by, which the spacing here does not place.
- Wall molding is the perimeter over its stock length, with no allowance for the cut at every corner or for a wall out of straight; columns, boxing-in and bulkheads add their own runs.
- Panels are counted on the ceiling tile page, which also gives the centred borders both ways.
Estimated cost — your price
This site holds no price list for this material — local prices vary too much to publish honestly. Enter your supplier's price and the result is costed with it.
Computed in your browser — nothing you enter is uploaded. Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.
Sources checked 2026-10-05 · v1.0.0
Regulatory standards & verification citations4
- Armstrong World Industries, How to Install Your Armstrong Suspended Ceiling (general installation instructions): main beams installed perpendicular to the joists on 4' centres; snap chalk lines for main beams 4' apart and screw in wire fasteners 4' apart; cross tees 2' apart for 2' x 4' panels; border panels the same size on opposite sides and as large as possible, found from the remainder plus one panel length divided by two (the sample 9' x 10' 6" room: 2' 6" and 1' 3" borders); for 2' x 2' panels the first main beam at the border panel size or the border panel + 24" from the wall; additional hanger wires may be needed for light fixtures
- Kanopi by Armstrong, How to Install Drop Ceilings: main beams carry the load of the grid, typically 12' or 6'; cross tees attach perpendicular to the main beams to make the 24" x 24" or 24" x 48" openings; wall moldings finish the perimeter; hanger wires attach to the joists; the left-over ends of cut main beams start additional rows
- Kanopi by Armstrong, ceiling grid range: 12' Wall Molding, Prelude 12' Heavy Duty Main Beam, Prelude 2' Cross Tee
- Judge Ceilings, Armstrong Ceiling Grid (UK merchant listing): 3.6m Armstrong Prelude Main Tees; Armstrong Prelude 1200mm Cross Tee; Armstrong Prelude 600mm Cross Tee; Armstrong Prelude Wall Angle 3m