  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "drop-ceiling-grid-calculator",
  "category": "renovation-construction",
  "title": "Drop or Suspended Ceiling Grid Calculator — Main Tees, Cross Tees, Wall Angle and Hangers",
  "description": "The whole drop (suspended) ceiling grid for a room: main beams, cross tees, wall angle and hanger wires, set out with equal border panels at each wall.",
  "url": "https://craftquantities.com/calculators/renovation-construction/drop-ceiling-grid-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/drop-ceiling-grid-calculator.json",
  "inputCount": 7,
  "testCaseCount": 3,
  "sourceCount": 4,
  "lastVerified": "2026-10-31",
  "citation": {
    "author": "Craft Quantities",
    "title": "Drop or Suspended Ceiling Grid Calculator — Main Tees, Cross Tees, Wall Angle and Hangers",
    "version": "1.0.1",
    "sourcesChecked": "2026-10-31",
    "url": "https://craftquantities.com/calculators/renovation-construction/drop-ceiling-grid-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Drop or Suspended Ceiling Grid Calculator — Main Tees, Cross Tees, Wall Angle and Hangers. Version 1.0.1. Sources checked 2026-10-31. https://craftquantities.com/calculators/renovation-construction/drop-ceiling-grid-calculator/",
      "apa": "Craft Quantities. (2026). Drop or Suspended Ceiling Grid Calculator — Main Tees, Cross Tees, Wall Angle and Hangers (Version 1.0.1) [Web calculator]. Retrieved from https://craftquantities.com/calculators/renovation-construction/drop-ceiling-grid-calculator/",
      "harvard": "Craft Quantities (2026) Drop or Suspended Ceiling Grid Calculator — Main Tees, Cross Tees, Wall Angle and Hangers (Version 1.0.1). Available at: https://craftquantities.com/calculators/renovation-construction/drop-ceiling-grid-calculator/",
      "bibtex": "@misc{craftquantities-calculators-renovation-construction-drop-ceiling-grid-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Drop or Suspended Ceiling Grid Calculator — Main Tees, Cross Tees, Wall Angle and Hangers},\n  version      = {1.0.1},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/renovation-construction/drop-ceiling-grid-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "roomLength",
      "label": "Room Length",
      "type": "number",
      "dimension": "length",
      "defaultValue": 5,
      "min": 0.5,
      "max": 60,
      "step": 0.1,
      "help": "The room's length, wall to wall, at ceiling height."
    },
    {
      "id": "roomWidth",
      "label": "Room Width",
      "type": "number",
      "dimension": "length",
      "defaultValue": 4,
      "min": 0.5,
      "max": 60,
      "step": 0.1,
      "help": "The room's width, wall to wall, at right angles to the length."
    },
    {
      "id": "panelSize",
      "label": "Panel Size",
      "type": "select",
      "defaultValue": "2x2",
      "optionsBySystem": {
        "imperial": [
          {
            "value": "2x2",
            "label": "2 x 2 ft"
          },
          {
            "value": "2x4",
            "label": "2 x 4 ft"
          }
        ],
        "metric": [
          {
            "value": "2x2",
            "label": "600 x 600 mm"
          },
          {
            "value": "2x4",
            "label": "1200 x 600 mm"
          }
        ]
      },
      "help": "The panels the grid holds: 2 x 2 or 2 x 4 ft, or 600 x 600 or 1200 x 600 mm."
    },
    {
      "id": "mainDirection",
      "label": "Which Way the Main Beams Run",
      "type": "select",
      "defaultValue": "length",
      "options": [
        {
          "value": "length",
          "label": "Along the room's length"
        },
        {
          "value": "width",
          "label": "Along the room's width"
        }
      ],
      "help": "Main beams run at right angles to the joists they hang from, Armstrong says."
    },
    {
      "id": "mainStockLength",
      "label": "Main Beam Length as Sold",
      "type": "number",
      "dimension": "length",
      "defaultValue": 3.6,
      "min": 0.6,
      "max": 6,
      "step": 0.01,
      "help": "The length one main beam comes in: 3.6 m (11.8 ft) for the metric Prelude main tee, 12 ft (3.66 m) for Armstrong's."
    },
    {
      "id": "wallAngleStockLength",
      "label": "Wall Angle Length as Sold",
      "type": "number",
      "dimension": "length",
      "defaultValue": 3,
      "min": 0.6,
      "max": 6,
      "step": 0.01,
      "help": "The length one piece of wall angle (wall molding) comes in: 3 m (9.8 ft) for the metric Prelude, 12 ft (3.66 m) for Armstrong's."
    },
    {
      "id": "hangerInterval",
      "label": "Hanger Spacing Along Each Main",
      "type": "number",
      "dimension": "length",
      "defaultValue": 1.2,
      "min": 0.3,
      "max": 2.4,
      "step": 0.05,
      "help": "How far apart the hanger wires go along a main beam: 4 ft (1.2 m) in Armstrong's instructions."
    }
  ],
  "sources": [
    {
      "label": "Armstrong World Industries, How to Install Your Armstrong Suspended Ceiling (general installation instructions): main beams installed perpendicular to the joists on 4' centres; snap chalk lines for main beams 4' apart and screw in wire fasteners 4' apart; cross tees 2' apart for 2' x 4' panels; border panels the same size on opposite sides and as large as possible, found from the remainder plus one panel length divided by two (the sample 9' x 10' 6\" room: 2' 6\" and 1' 3\" borders); for 2' x 2' panels the first main beam at the border panel size or the border panel + 24\" from the wall; additional hanger wires may be needed for light fixtures",
      "url": "https://www.armstrongceilings.com/pdbupimages-clg/227762.pdf/download/general-installation.pdf"
    },
    {
      "label": "Kanopi by Armstrong, How to Install Drop Ceilings: main beams carry the load of the grid, typically 12' or 6'; cross tees attach perpendicular to the main beams to make the 24\" x 24\" or 24\" x 48\" openings; wall moldings finish the perimeter; hanger wires attach to the joists; the left-over ends of cut main beams start additional rows",
      "url": "https://kanopibyarmstrong.com/pages/how-to-install-drop-ceilings"
    },
    {
      "label": "Kanopi by Armstrong, ceiling grid range: 12' Wall Molding, Prelude 12' Heavy Duty Main Beam, Prelude 2' Cross Tee",
      "url": "https://kanopibyarmstrong.com/collections/armstrong-ceiling-grid"
    },
    {
      "label": "Judge Ceilings, Armstrong Ceiling Grid (UK merchant listing): 3.6m Armstrong Prelude Main Tees; Armstrong Prelude 1200mm Cross Tee; Armstrong Prelude 600mm Cross Tee; Armstrong Prelude Wall Angle 3m",
      "url": "https://judge-ceilings.co.uk/armstrong-ceiling-grid"
    }
  ],
  "testCases": [
    {
      "name": "Armstrong's sample room, 9 ft x 10 ft 6 in, 2 x 4 panels, mains along the 10 ft 6 in side",
      "inputs": {
        "roomLength": 3.2004,
        "roomWidth": 2.7432000000000003,
        "panelSize": "2x4",
        "mainDirection": "length",
        "mainStockLength": 3.6576000000000004,
        "wallAngleStockLength": 3.6576000000000004,
        "hangerInterval": 1.2192
      },
      "expected": 2,
      "toleranceDecimalPlaces": 0,
      "unit": "main beams",
      "confidence": "high",
      "steps": [
        {
          "label": "Lines of main beams",
          "value": 2,
          "unit": "lines"
        },
        {
          "label": "Long cross tees, border tees included",
          "value": 15,
          "unit": "tees"
        },
        {
          "label": "Short cross tees, for 2 x 2 panels",
          "value": 0,
          "unit": "tees"
        },
        {
          "label": "Wall angle pieces",
          "value": 4,
          "unit": "pieces"
        },
        {
          "label": "Hanger wires",
          "value": 6,
          "unit": "wires"
        },
        {
          "label": "Border across the mains, at each wall",
          "value": 0.7620000000000001,
          "unit": "m"
        },
        {
          "label": "Border along the mains, at each end",
          "value": 0.38100000000000006,
          "unit": "m"
        },
        {
          "label": "Perimeter for the wall angle",
          "value": 11.8872,
          "unit": "m"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "A 5 x 4 m room of 2 x 2 panels on the 2 ft module, 12 ft (3.66 m) mains along the length",
      "inputs": {
        "roomLength": 5,
        "roomWidth": 4,
        "panelSize": "2x2",
        "mainDirection": "length",
        "mainStockLength": 3.66,
        "wallAngleStockLength": 3.66,
        "hangerInterval": 1.2
      },
      "expected": 5,
      "toleranceDecimalPlaces": 0,
      "unit": "main beams",
      "confidence": "high",
      "steps": [
        {
          "label": "Lines of main beams",
          "value": 3,
          "unit": "lines"
        },
        {
          "label": "Long cross tees, border tees included",
          "value": 32,
          "unit": "tees"
        },
        {
          "label": "Short cross tees, for 2 x 2 panels",
          "value": 27,
          "unit": "tees"
        },
        {
          "label": "Wall angle pieces",
          "value": 5,
          "unit": "pieces"
        },
        {
          "label": "Hanger wires",
          "value": 15,
          "unit": "wires"
        },
        {
          "label": "Border across the mains, at each wall",
          "value": 0.4759999999999998,
          "unit": "m"
        },
        {
          "label": "Border along the mains, at each end",
          "value": 0.3663999999999999,
          "unit": "m"
        },
        {
          "label": "Perimeter for the wall angle",
          "value": 18,
          "unit": "m"
        }
      ],
      "basis": "cited",
      "sourceIndex": 1
    },
    {
      "name": "A 10 x 3 m corridor of 2 x 4 panels on the 2 ft module, 12 ft (3.66 m) mains run across it",
      "inputs": {
        "roomLength": 10,
        "roomWidth": 3,
        "panelSize": "2x4",
        "mainDirection": "width",
        "mainStockLength": 3.66,
        "wallAngleStockLength": 3.66,
        "hangerInterval": 1.2
      },
      "expected": 8,
      "toleranceDecimalPlaces": 0,
      "unit": "main beams",
      "confidence": "high",
      "steps": [
        {
          "label": "Lines of main beams",
          "value": 8,
          "unit": "lines"
        },
        {
          "label": "Long cross tees, border tees included",
          "value": 36,
          "unit": "tees"
        },
        {
          "label": "Short cross tees, for 2 x 2 panels",
          "value": 0,
          "unit": "tees"
        },
        {
          "label": "Wall angle pieces",
          "value": 8,
          "unit": "pieces"
        },
        {
          "label": "Hanger wires",
          "value": 24,
          "unit": "wires"
        },
        {
          "label": "Border across the mains, at each wall",
          "value": 0.7327999999999998,
          "unit": "m"
        },
        {
          "label": "Border along the mains, at each end",
          "value": 0.5855999999999999,
          "unit": "m"
        },
        {
          "label": "Perimeter for the wall angle",
          "value": 26,
          "unit": "m"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    }
  ]
}