SettingsSettings for this calculationUS
Waste is set to 5% by hand. Pick a tier above to replace it, or keep your own figure.
The total attic roof deck area to be covered with radiant barrier foil.
Measure the underside roof deck area (rafter bays) where the reflective foil will be installed, typically stapled to the underside of the rafters.
Extra material to allow for cut waste and overlaps.
5% is typical for a simple gable roof; increase it for complex roof shapes with many hips, valleys, or obstructions.
Radiant barrier material needed
1,690 sq ft
They open the calculator with your figures already in it
Radiant Barrier Foil Coverage Calculator: 1,690 sq ft — shown in imperial, US market. The link sets both, so the result they see is the one on your screen.
Show calculation logicHide calculation logic
How this was calculated
Formula source(s)
- Material needed = roof area × (1 + waste allowance), the standard coverage-with-waste method applied to reflective radiant barrier foil installation
Inputs used
- Roof Deck Area
- 1610 sq ft
- Waste Allowance (%)
- 5
What this calculation does not cover
- Foil is a vapour barrier as well as a reflector, and where it lands decides whether that matters. Laid over the loft floor on top of the insulation, an unperforated foil sits on the cold side of the ceiling and traps moisture rising out of the house in the insulation beneath it - perforated products exist precisely so the assembly can still dry, and choosing between them is a climate and construction decision rather than a coverage one. The same job goes wrong at the eaves: foil run tight into them blocks the soffit ventilation the roof space relies on, and the barrier's own benefit assumes that air is still moving.
- It is a sheet of metal in a space full of wiring and fittings. Foil conducts, so it must be kept clear of live parts, junction boxes, old rubber-insulated or knob-and-tube wiring, flues, and the tops of recessed downlights, which carry their own clearance requirements - stapling a continuous conductive sheet across the rafters is not a neutral act. Where it is left exposed in an accessible roof space its surface-burning rating matters as well; this sum counts area and nothing else.
Estimated cost — your price
This site holds no price list for this material — local prices vary too much to publish honestly. Enter your supplier's price and the result is costed with it.
Computed in your browser — nothing you enter is uploaded. Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.
Sources checked 2026-09-06 · in the site-wide review of 2026-09-06 · v1.0.1
Regulatory standards & verification citations1
- Material needed = roof area × (1 + waste allowance), the standard coverage-with-waste method applied to reflective radiant barrier foil installation
Cite this page
Your workspace
Most jobs need more than one number. Add the calculators you need next and they open right here, underneath this one — your figures stay on screen and nothing is lost to a page change.