Soil Nail Pull-Out Safety Factor Calculator
Check a soil nail's pull-out safety factor against the standard FHWA minimum of 2.0.
Computed in your browser — nothing you enter is uploaded. Figures are presented in United States units and terminology, and each formula’s basis is cited under regulatory standards below.
Last verified 2026-08-26 · v1.0.0
Pull-out safety factor
3.557 (target ≥2.0)
PASSES the standard FHWA minimum pullout safety factor of 2.0.
- Pullout capacity
- 284.57 kN
With the figures above, the pull-out safety factor comes to 3.56 (target ≥2.0). This is presented for United States. Building in another market? Change the selector above and the units and terminology follow.
Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.
Regulatory standards & verification citations
- FHWA GEC No. 7 soil nail wall design: pullout capacity = nominal bond strength x pi x drill hole diameter x bonded length; a minimum pullout safety factor of 2.0 is standard practice