  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "soil-nail-pullout-calculator",
  "category": "heavy-civil",
  "title": "Soil Nail Pull-Out Safety Factor Calculator",
  "description": "Check a soil nail's pull-out safety factor against the standard FHWA minimum of 2.0.",
  "url": "https://craftquantities.com/calculators/heavy-civil/soil-nail-pullout-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/soil-nail-pullout-calculator.json",
  "inputCount": 4,
  "testCaseCount": 2,
  "sourceCount": 1,
  "lastVerified": "2026-09-06",
  "citation": {
    "author": "Craft Quantities",
    "title": "Soil Nail Pull-Out Safety Factor Calculator",
    "version": "1.0.1",
    "sourcesChecked": "2026-09-06",
    "url": "https://craftquantities.com/calculators/heavy-civil/soil-nail-pullout-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Soil Nail Pull-Out Safety Factor Calculator. Version 1.0.1. Sources checked 2026-09-06. https://craftquantities.com/calculators/heavy-civil/soil-nail-pullout-calculator/",
      "apa": "Craft Quantities. (2026). Soil Nail Pull-Out Safety Factor Calculator (Version 1.0.1) [Web calculator]. Retrieved from https://craftquantities.com/calculators/heavy-civil/soil-nail-pullout-calculator/",
      "harvard": "Craft Quantities (2026) Soil Nail Pull-Out Safety Factor Calculator (Version 1.0.1). Available at: https://craftquantities.com/calculators/heavy-civil/soil-nail-pullout-calculator/",
      "bibtex": "@misc{craftquantities-calculators-heavy-civil-soil-nail-pullout-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Soil Nail Pull-Out Safety Factor Calculator},\n  version      = {1.0.1},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/heavy-civil/soil-nail-pullout-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "bondStrength",
      "label": "Nominal Bond Strength (qs)",
      "type": "number",
      "dimension": "pressure",
      "defaultValue": 100000,
      "min": 20000,
      "max": 400000,
      "step": 5,
      "help": "The grout-to-soil bond strength, from FHWA GEC-7 tables or site-specific pullout testing."
    },
    {
      "id": "holeDiameter",
      "label": "Drill Hole Diameter",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0.15,
      "min": 0.01,
      "max": 0.4,
      "step": 0.01,
      "help": "The diameter of the drilled hole for the nail and grout."
    },
    {
      "id": "bondedLength",
      "label": "Bonded Length",
      "type": "number",
      "dimension": "length",
      "defaultValue": 6,
      "min": 0.01,
      "max": 20,
      "step": 0.5,
      "help": "The length of the nail bonded (grouted) beyond the potential failure surface."
    },
    {
      "id": "designLoad",
      "label": "Design (Working) Load",
      "type": "number",
      "dimension": "force",
      "defaultValue": 80000,
      "min": 5000,
      "max": 1000000,
      "step": 5,
      "help": "The nail's design tensile load."
    }
  ],
  "sources": [
    {
      "label": "FHWA GEC No. 7 soil nail wall design: pullout capacity = nominal bond strength x pi x drill hole diameter x bonded length; a minimum pullout safety factor of 2.0 is standard practice"
    }
  ],
  "testCases": [
    {
      "name": "qs=100kPa, 0.15m hole, 6m bonded, 80kN load (pass)",
      "inputs": {
        "bondStrength": 100000,
        "holeDiameter": 0.15,
        "bondedLength": 6,
        "designLoad": 80000
      },
      "expected": 3.53,
      "toleranceDecimalPlaces": 1,
      "unit": "(target ≥2.0)",
      "confidence": "medium",
      "steps": [
        {
          "label": "Pullout capacity",
          "value": 282.7433388230814,
          "unit": "kN"
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    },
    {
      "name": "qs=80kPa, 0.1m hole, 4m bonded, 100kN load (fail)",
      "inputs": {
        "bondStrength": 80000,
        "holeDiameter": 0.1,
        "bondedLength": 4,
        "designLoad": 100000
      },
      "expected": 1.01,
      "toleranceDecimalPlaces": 1,
      "unit": "(target ≥2.0)",
      "confidence": "medium",
      "steps": [
        {
          "label": "Pullout capacity",
          "value": 100.53096491487338,
          "unit": "kN"
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    }
  ]
}