SettingsSettings for this calculationUS
The amount from the bill, in whatever currency you are billed in.
Use the energy portion of the bill, not the total. Standing charges, service fees and taxes are not consumption and will inflate the answer if you include them — on a small account they can be a third of the total.
The price of one kWh on the same bill.
The unit rate the energy charge was billed at. On a tariff with day and night bands, split the energy charge by band and divide each by its own rate — a single blended division is an average, not a measurement.
Energy used
Needs your Unit rate (per kWh)
This page does not assume a price. Enter yours and the answer appears here.
They open the calculator with your figures already in it
Running Cost to kWh Calculator — shown in imperial, US market. The link sets both, so the result they see is the one on your screen.
Show calculation logicHide calculation logic
How this was calculated
Formula source(s)
- Arithmetic only: energy = amount spent ÷ your unit rate. No tariff data is published here.
Inputs used
- Amount spent
- 100
- Unit rate (per kWh)
What this calculation does not cover
- A bill covers a meter, not a machine. Dividing an account's spend by a rate returns the whole site's consumption, and everything else on that supply — lighting, refrigeration, standby loads, another unit sharing the meter — is inside the answer. Attributing all of it to the one piece of equipment under discussion is the error this figure most readily supports, and sub-metering the plant is what actually settles the question.
- Consumption follows weather and occupancy, so two billing periods are not a controlled experiment. A mild winter, a longer hot spell, or a change in how many people are in the building moves heating and cooling energy by more than most retrofits do. Comparing period against period without normalising for degree days and occupied hours credits the measure with the season.
- A bill raised on an estimated read is not a measurement. Suppliers estimate between visits and correct at the next actual reading, so kilowatt-hours backed out of an estimated period are the supplier's model of your use rather than your use, and the correction — which can be substantial — lands in a later bill attached to the wrong months.
Computed in your browser — nothing you enter is uploaded. Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.
Sources checked 2026-09-16 · v1.1.0
Regulatory standards & verification citations1
- Arithmetic only: energy = amount spent ÷ your unit rate. No tariff data is published here.
Cite this page
Your workspace
Most jobs need more than one number. Add the calculators you need next and they open right here, underneath this one — your figures stay on screen and nothing is lost to a page change.
Bills arrive in money and equipment is rated in kilowatts, so verifying an efficiency claim means crossing between the two. Working backwards from spend is the direction nobody publishes a calculator for, and it is the one that lets you sanity-check a payback claim against what the plant could physically have consumed — at the unit rate on the bill, which only you have.