Verification

First-party · measured every build

How every calculator is checked, and what changed when

The checks the site runs on its own arithmetic, counted from the code at build time; the record of what changed month by month; and every confirmed error, with the date it was found.

  • 3,536Test vectors, run on every change
  • 1,181Calculators checked
  • 31Confirmed errors, published

Checked by the site itself, and said so

Every check on this page is the site's own: its automated tests, its build gates and its audits. They show that each calculation does what its author intended and that a change cannot move a published answer unnoticed. They do not show that the author chose the right method.

No outside body has reviewed or certified these calculators, and nothing here claims otherwise. If that changes, this page will name who reviewed what.

The checks

What runs before a change can ship

Each check is a test in the site's suite or a step of its build. A failing check stops the change.

  1. Pinned test vectors

    3,536 vectors across 1,181 calculators: inputs, the expected answer and a tolerance in decimal places. The suite runs each one through the calculator's own code on every change; a change that moves a published answer fails.

  2. The edges of every input

    Every numeric input that declares a range is driven to its minimum, its maximum and its midpoint, one at a time. The answer and every line of its breakdown must stay a finite number.

  3. Conversions that must round-trip

    Every pair of opposite converters is run there and back; the second must return the first one's input to within a ten-thousandth, so a factor updated on one side alone is caught.

  4. Both unit systems

    The calculation service runs every vector as well and must show the answer the page shows, in metric and in imperial, so the units a reader sees cannot drift from the arithmetic.

  5. The formula library

    28 published equations are run against 26 calculators on 87 of their vectors; the build stops if an equation and the code beneath it disagree.

  6. A site-wide audit

    On 2026-09-06 every calculator then published was read again, one by one, for its arithmetic, units, bounds and sources; the wrong numbers it confirmed were corrected and are in the log below.

The equations, with the vectors that pin them

Coverage

What the vectors hold

Counted from the registry when the site is built.

  • 3,038

    show the working, step by step

  • 1,205

    name the source they rest on

  • 1,414

    belong to a calculator with a single source

  • 917

    belong to a calculator with several sources, not told apart

Every vector, field by field

What changed when

The record, month by month

From each calculator's own changelog and the date each confirmed error was found.

The record, month by month
MonthCalculators publishedLater versionsErrors found
2026-089271322
2026-0918782723
2026-1059916
2026-11820

A later version is any change a calculator records in its changelog after its first release: a corrected answer, a new output, a revised source or wording. 1,052 are recorded so far.

The audit log

Every confirmed error, newest first

The corrections ledger, as a log: when each error was found and how. Each entry there says what was wrong, what is correct and what now prevents it.

Every confirmed error, newest first
FoundErrorFound by
2026-10-11The shingle roof takeoff counted stick-framed ceiling joists over the gable overhangs, where there is no ceilingroutine work
2026-10-05The horizontal tank page said two hemispherical heads hold a sixth of the tank; they hold a quarterroutine work
2026-10-05The extension ladder page named OSHA's 75.5° but worked to one foot out for every four upthe site's own audit
2026-10-05The pool and hot tub pages rounded a cubic foot to 7.48 gallons, so a 75 m³ pool read 74,990 litresthe site's own audit
2026-10-05The screed thickness page worked its cement by volume, so its 60 m² floor took 73 bags where the standard's mix takes 80the site's own audit
2026-10-05The U-value converter explained its 5.678 factor the wrong way roundroutine work
2026-09-25The deck joist page cited the code section for beams, not joistsroutine work
2026-09-25The diagonal tile waste page said to enter the wrong side of a rectangular tileroutine work
2026-09-25The gravel base calculator weighed a compacted base at a loose densityroutine work
2026-09-25The gravel calculator weighed the finished layer at a loose density, and came out a sixth lightroutine work
2026-09-25The heating mat page told imperial readers to buy mat sizes that are not soldroutine work
2026-09-25The refinance page opened on two interest rates the site had chosenroutine work
2026-09-25The replastered-room worked example described walls its own room could not haveroutine work
2026-09-25The shingle roof takeoff measured one eave and treated the ridge vent as a replacement for the caproutine work
2026-09-25Twenty-six job takeoffs measured something their own calculators said they did notroutine work
2026-09-25The wet room tanking page counted each pipe twice, as a collar and again as taperoutine work
2026-09-25The tile adhesive calculator asked for half as much adhesive again as the manufacturers printroutine work
2026-09-25The site described more checking than it had doneroutine work
2026-09-19Saving a version of an estimate did nothing on some browsers, and said nothingthe owner
2026-09-14A standard cited by three calculators had no page, and every check passedthe site's own audit
2026-09-14Three pages used two different densities for bark mulchroutine work
2026-09-14A labour rate no page can ever offerthe site's own audit
2026-09-14The report counting which standards qualify undercounted by threeroutine work
2026-09-14Fourteen standards pages ran five sentences together into one block of textroutine work
2026-09-13A published size budget had been broken live for months with nothing checking itthe site's own audit
2026-09-13Body text was squeezed into a narrow column down the left of wide pagesthe owner
2026-09-13A tool page shipped with no title, description or canonical link at allthe site's own audit
2026-09-06141 calculators were producing a wrong numberthe site's own audit
2026-09-02A wire-sizing page answered loads above 70 A with a conductor rated for 70 Athe site's own audit
2026-08-28Every calculator page on the live site was crashing during start-uproutine work
2026-08-28Eight calculators read litres as cubic metres — every answer 1,000× outa reader

The full ledger

What this does not show

  • Whether a formula is the right one for a job: a vector holds code to its author's intent.
  • Anything about a real building: the inputs, the product bought and the code in force are outside what a test can see.
  • A certificate of any kind. Nothing on this site sizes a member or confirms that a structure is safe.

Report an error

Send the page, the inputs with their units, what you got, what you expected and the source of your figure to contact@craftquantities.com. A confirmed error is fixed and published in the ledger.