Formula library

CC BY 4.0 · JSON

Stair geometry

A straight flight is set out from one measurement, floor to floor, and one choice, a target riser. Everything else follows: how many risers, how tall each one is, and the going that makes them comfortable.

  • 3Formulas
  • 1Calculators that run them
  • 12Test vectors

Number of risers

riser-count

How many risers a flight needs for a total rise and a target riser height.

n=max⁡(1,round⁡(Hrt))
n = max(1, round(H / rₜ))

Symbols

Number of risers: Symbols
SymbolMeaningMetricImperial
nNumber of risers——
HTotal rise, finished floor to finished floormft
rtTarget riser heightmft

Worked example

A pinned test vector of the Stair Rise & Run Calculator.

  • H = 2.8 m (9.18635 ft) (Total rise, finished floor to finished floor)
  • rt = 0.185 m (0.606955 ft) (Target riser height)

gives n = 15. The calculator's own compute function returns 15.

Calculators that run it

Test vectors

Number of risers: Test vectors
CalculatorInputsFormulaCalculator returns
Stair Rise & Run CalculatorH = 2.8 · rt = 0.1851515pinned
Stair Rise & Run CalculatorH = 3.5 · rt = 0.17782020pinned
Stair Rise & Run CalculatorH = 2.7 · rt = 0.1751515pinned
Stair Rise & Run CalculatorH = 2.6 · rt = 0.191414pinned

Actual riser height

riser-height

The height of every riser once the count is fixed.

R=Hn
R = H / n

Symbols

Actual riser height: Symbols
SymbolMeaningMetricImperial
RActual riser heightmft
HTotal risemft
nNumber of risers——

Worked example

A pinned test vector of the Stair Rise & Run Calculator.

  • H = 2.8 m (9.18635 ft) (Total rise)
  • n = 15 (Number of risers)

gives R = 0.186667 m (0.612423 ft). The calculator's own compute function returns 7.34908 in.

Calculators that run it

Test vectors

Actual riser height: Test vectors
CalculatorInputsFormulaCalculator returns
Stair Rise & Run CalculatorH = 2.8 · n = 150.1866677.34908 in
Stair Rise & Run CalculatorH = 3.5 · n = 200.1756.88976 in
Stair Rise & Run CalculatorH = 2.7 · n = 150.187.08661 in
Stair Rise & Run CalculatorH = 2.6 · n = 140.1857147.31159 in

Going from the comfort rule

comfort-going

The tread depth that suits a riser height under the 2R + G rule.

G=c−2×R
G = c − 2 × R

Symbols

Going from the comfort rule: Symbols
SymbolMeaningMetricImperial
GGoing (tread depth)mft
cThe rule's constant, 25 in (635 mm)mft
RRiser heightmft

Worked example

A pinned test vector of the Stair Rise & Run Calculator.

  • c = 0.635 m (2.08333 ft) (The rule's constant, 25 in (635 mm))
  • R = 0.186667 m (0.612423 ft) (Riser height)

gives G = 0.261667 m (0.858486 ft). The calculator's own compute function returns 10.3018 in.

Calculators that run it

Test vectors

Going from the comfort rule: Test vectors
CalculatorInputsFormulaCalculator returns
Stair Rise & Run Calculatorc = 0.635 · R = 0.1866670.26166710.3018 in
Stair Rise & Run Calculatorc = 0.635 · R = 0.1750.28511.2205 in
Stair Rise & Run Calculatorc = 0.635 · R = 0.180.27510.8268 in
Stair Rise & Run Calculatorc = 0.635 · R = 0.1857140.26357110.3768 in

Using the equations

How to read them

Round the riser count to the nearest whole number, then divide the total rise by it. Every riser in a flight must be the same height.

There is one tread fewer than risers: the top floor is the last step.

The comfort rule reads twice the riser plus the going at about 25 in (635 mm); some codes give a range, such as 550 to 700 mm.

Read every symbol in one column: the equation holds in either system as long as the units are not mixed.

Each row is a registry test vector, run through the equation and through the calculator. Only rows on which the two agree are published.

These are quantity equations, not design checks. Nothing here sizes a member or confirms that a structure is safe; that is for the engineer or building official responsible for the work.

Limits

Where they stop describing the job

Building codes set maximum risers, minimum goings, pitch and headroom; the equations produce a geometry, and the code in force decides whether it is allowed.

  • Finished floor levels, not structural ones, set the total rise: measure after the floor build-up is known.

Sources

What the calculators cite

The citations of the calculators that run these equations, as each calculator states them.

  1. Comfortable stair proportion rule of thumb: 2 x riser height + tread depth = 24-25 inches; a riser of about 175–190 mm (6.9–7.5 in) is a comfortable target that sits inside all four codes this page checksCited by: Stair Rise & Run Calculator
  2. US: IRC 2024 R311.7.5 — maximum riser height 7.75 in, minimum tread depth (going) 10 inCited by: Stair Rise & Run Calculator
  3. UK: Approved Document K (2013), Section 1, Table 1.1 — a private stair's rise 150–220 mm and going 220–300 mm, pitch at most 42°, and twice the rise plus the going between 550 and 700 mmCited by: Stair Rise & Run Calculator
  4. Australia: ABCB Housing Provisions Standard, Part 11.2, clause 11.2.2 and Table 11.2.2a, called up by NCC Volume Two for houses; the same table in NCC 2022 and NCC 2025. A stairway other than a spiral stair has risers of 115–190 mm, goings of 240–355 mm and a slope relationship 2R + G of 550–700 mm; each flight has not more than 18 and not less than 2 risers (11.2.2(1)(a)); goings and risers are constant through a flight, within 5 mm between neighbours and 10 mm across the flight (11.2.2(1)(c)); and risers have no opening a 125 mm sphere can pass through (11.2.2(1)(d)). Under 11.2.2(2), a stairway serving only non-habitable rooms such as attics and storerooms that are not used on a regular or daily basis may use Table 11.2.2b instead: riser 130–225 mm, going 215–355 mm and 2R + G 540–700 mm. NCC Volume One, clause D3D14 and Table D3D14, gives a public stairway in other buildings a going of 250–355 mm with the same risers and 2R + GCited by: Stair Rise & Run Calculator
  5. Canada: National Building Code of Canada 2020, Volume 2, Division B, Section 9.8, for a private stair (one serving a single dwelling unit, a house with a secondary suite, or a garage serving either): rise 125–200 mm (Article 9.8.4.1, Table 9.8.4.1), run 255–355 mm (Article 9.8.4.2, Table 9.8.4.2), each tread's depth between its run and its run plus 25 mm (Sentence 9.8.4.2.(2)), risers and runs uniform within 5 mm between neighbours and 10 mm across a flight (Article 9.8.4.4), no flight more than 3.7 m high (Article 9.8.3.3), and 1 950 mm of clear height over a stair serving a single dwelling unit (Sentence 9.8.2.2.(3)). A public stair has a rise of 125–180 mm and a run of at least 280 mm. Provinces and territories adopt the NBC with amendments of their own, so check the edition in force where you buildCited by: Stair Rise & Run Calculator

Data

Cite or reuse this family

The same equations, symbols, calculators and vectors as one JSON file.

https://craftquantities.com/formulas/stairs.json

The text and the data of the formula library are published under the Creative Commons Attribution 4.0 licence (CC BY 4.0): reuse them, in any medium and for any purpose, with a credit to Craft Quantities and a link to the page.

Cite as: Craft Quantities, “Stair geometry”, https://craftquantities.com/formulas/stairs/