Solar Panel PV Wire Sizing Calculator
Calculate the minimum conductor cross-sectional area needed for a PV circuit run at a target maximum voltage drop.
Computed in your browser — nothing you enter is uploaded. Figures are presented for United States against IRC 2024, and every formula is cited under regulatory standards below.
Last verified 2026-08-26 · v1.0.0
Minimum conductor cross-sectional area
5.47 mm²
Convert the resulting minimum cross-sectional area to the next larger standard wire gauge (AWG) or metric conductor size — do not round down. Also verify the selected conductor's ampacity rating (NEC Table 310.16, with appropriate temperature/conduit fill derating) independently meets or exceeds the circuit current.
At the values currently entered, the minimum conductor cross-sectional area works out to 5.47 mm². Confidence is moderate: the method is sound, but real materials and site conditions vary. Figures are shown for United States, where IRC 2024 is the governing residential reference; switch the market above if you are building elsewhere.
Add the equipment this sizes
This result is a specification — 5.469 mm² — not a quantity. Put the thing it sizes into your project: how many, what you call it, and your supplier’s price.
[Schema Verified] Computed in alignment with American Concrete Institute (ACI 318-19) formulas and International Residential Code (IRC 2024) spatial boundaries.
Regulatory standards & verification citations
- Conductor area = (2 x resistivity x one-way distance x current) ÷ maximum allowable voltage drop, the standard DC circuit voltage-drop sizing method applied to a solar PV source/output circuit run (the factor of 2 accounts for the round-trip conductor length)